DENT Instruments’ EXCUWI ELITEpro XC Energy Logger with WiFi Communication and an internal antenna is a primary member of the ELITEpro XC series. Boasting 4 analog input channels, configurable for voltage or current input, the EXCUWI analyzes and stores electrical consumption data. The energy logger monitors current on each phase using direct connections to each phase of the voltage and interchangeable CT options, like RoCoil or split-core CTs. See the accessories tab for available DENT CTs.
Demand data, kWh/kW energy and nearly all related monitoring and diagnostic energy parameters on single or three-phase circuit installations can be captured with the EXCUWI. Even electrical load diagnostic parameters, like power factor (Apparent and Displacement) can be captured.
With the EXCUWI’s specific configuration and supplied ELOG Software, the logger can be accessed from any PC on the network via the WiFi interface. Or, use the EXCUWI as its own WiFi hotspot to observe data in real-time from up to 100 ft away.
TECHNICAL | |
Service Type | Single Phase (two wire or three wire), Three Phase-Four Wire (WYE), Three Phase-Three Wire (Delta), DC Systems (Solar/Battery) |
Voltage Channels | 3 channels, CAT III, 0-600 VAC (line-to-line) or 600 VDC* |
Current Channels | 4 channels, .67 VAC max, +/- 1 VDC. Ideal for 333 mV full scale CTs |
Maximum Current Input | External transducer dependent. 200% of current transducer rating (mV CTs) Measure up to 6000A with RoCoil CTs. |
Measurement Type | True RMS using high-speed digital signal processing (DSP) |
Line Frequency | DC/50/60 Hz* |
Waveform Sampling | 12 kHz |
Channel Sampling Rate | .125 seconds |
Integration Period | 1, 3, 15, 30 seconds; 1, 2, 5, 10, 15, 20, and 30 minutes; 1 and 12 hours, 1 day |
Energy Measurements | Volts, Amps, Amp-Hrs (Ah), kW, kWh, kVAR, kVARh, kVA, kVAh, Displacement Power Factor (dPF). All parameters for each phase and for system total. |
Analog Measurements | 0-10 Volts, 0-20 or 4-20 mA current loop. Non-isolated, external power for current loop. User scaling for sensor reporting in physical units. |
Accuracy | Better than 1% (<0.2% typical) for V, A, kW, kVAR, kVA, PF, Analog |
Resolution | 0.01 Amp, 0.001 Volt, 1 Watt, 1 VAR, 1 VA, 0.01 PF, 0.001 ANA |
LED Indicators | Tri-color (red, green, blue): 1 LED indicates communication (blue for wireless, Bluetooth® or Ethernet), 4 LEDs for correct phasing (PhaseChek™). |
POWER | |
Line-Power | From L1 Phase to L2 Phase. 80-600V (AC or DC) CAT III DC/50/60 Hz, 125 mA, 5 W, or 10 VA max. Non-user replaceable .5 Amp internal fuse protection. |
Power In | 6-10 VDC, 500 mA |
Power Out | 6 VDC, 200 mA max |
COMMUNICATIONS | |
USB (Standard) | USB standard (Type B). 1.8 M (6 ft) A-to-B USB Cable (included) |
Ethernet (Standard) | Standard RJ-45 Connector supports 10/100 MB Ethernet over Cat 5 or better. Configure for DHCP or Static IP. |
WI-FI Adapter | Internal antenna: typical range 75-300 ft. |
MECHANICAL | |
Operating Temperature | -7 to + 60 °C (20 to 140 °F) |
Operating Humidity | 5% to 95% non-condensing |
Enclosure Type | ABS plastic, 94-V0 flammability rating |
Weight | 340 g (12 ounces) |
Dimensions | 21.6 x 6.3 x 4.7 cm (8.5” x 2.5” x 1.9”) |
- • True RMS Current Reading
- • Energy Surveys
- • Load Profiling
- • Verification Studies
- • Energy Audits