The Amprobe AMP-25 is a pocket-sized clamp meter that is designed to measure AC/DC load current and inrush current for motors.
Feature | AMP-25 | Best Accuracy |
AC Current (1) | 60.00 / 300.0 A | +/-(1.5% + 5 LSD) |
DC Current (2) | 60.00 / 300.0 A | +/-(1.5% + 5 LSD) |
Low Pass Filter | 300.0 A | +/-(3.5% + 5 LSD) |
True-RMS | • |
|
Inrush Current | • |
|
Non-Contact Voltage | • |
|
Data Hold | • |
|
(1) Note: Crest Factor (C.F.) may be up to 3.0 as 4000 counts. |
General Specifications | AMP-25 |
Display | Digital: 6000 counts, updates 2/sec |
Range | Autoranging |
Overrange Indication | OL or -OL |
Operating Temperature | 32 °F to 86 °F (0 °C to 30 °C), ≤ 80% RH 86 °F to 104°F (30°C to 40 °C), ≤ 75% RH 104 °F to 122°F (40°C to 50 °C), ≤ 45% RH |
Operating Altitude | ≤ 2000 m |
Storage Temperature | -4 °F to 140 °F (-20°C to +60°C) |
Pollution Degree | 2 |
Temperature Coefficient | 0.2 x (specified accuracy)/ °F(<64.4°F, >82.4°F)/ °C (<18 °C, >28 °C) |
Vibration Requirement | MIL-PRF-28800F for A Class 2 |
Drop Proof | 4 feet (120 cm) |
Battery | Two 1.5 V LR44 size button batteries |
Battery Life | 20 hours typical |
Low Battery Indication | |
Auto Power Off | Idle for 20 minutes |
Overvoltage Category | CAT III 600 V |
Safety Compliance | IEC/EN 61010-1, IEC/EN 61010-2-030, IEC/EN 61010-2-032 |
EMC Compliance | IEC/EN 61326-1 |
Agency Approval | |
Dimensions (H x W x L) | 5.8 x 2.4x 1.3 in (147 x 60 x 32 mm) |
Weight | Approximately 0.31 lb (140 g) with batteries installed |
Jaw Opening & Conductor Diameter | 1.0 in (25 mm) max. |