We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
Equipped with all the features and functions of the OX5042 2150.21, the AEMC OX5042 2150.23 Handscope Portable Oscilloscope Kit w/ MN379T & MF 3000-24-1-1 also comes with a field case (IP67),USB cable and driver, 1 10:1 600V/BNC-M probe, US wall plug, alligator clips and test probes, Cat #2153.02 – AC Current Probe Model MN379T (5A, 200nV/A & 100A, 10mV/A, 10ft. BNC Lead), Cat #2132.63 – MiniFlex® 3000-24-1-1 (3000A, 1mV/A, 24” MiniFlex® sensor, 10 ft. BNC connector), BNC adapter, 6 1.2V NiMH rechargeable batteries, set of 2 10 ft. color-coded (Rd/Bk) leads, quick start guide, USB drive with software and user manual.
OX5042 Handscope Portable Oscilloscope | |
CHANNELS | |
Inputs / Bandwidth | 2 X 600V Isolated channels / 40MHz |
Input Impedance | 1MΩ ± 0.5%, 17pF |
INTERFACE | |
Screen Specifications | Color 3.5" TFT LCD 320 x 240 – LED Backlighting |
Display Mode | 2500 real acquisition points on screen |
Traces On Screen | 2 Traces + 2 References + memory trace or Math calculation |
Front Panel Control | 24 keys |
VERTICAL | |
Vertical Sensitivity | 5mV to 200V/div and up to 156μV/div in vertical zoom mode (12-bit converter) – Accuracy ± 1% |
Max Input Voltage | 600Vrms CAT III – Derating -20dB per decade from 100kHz |
HORIZONTAL | |
Time Base Speed | 25ns/div to 200s/div. – accuracy 0.1-Roll mode from 100ms to 200s/div |
Horizontal Zoom | Zoom factor : x1, x2, x5 |
TRIGGER | |
Mode | On all channels: Auto, Triggered, One-shot & trigger Roll |
Type | Edge, Pulse width (20ns to 20s) |
Coupling | AC or DC (dependent of the coupling of the triggering channel)- HF, LF, or noise rejection |
Sensitivity | ≤ 1.2 divisions p-p up to 40 MHz |
DIGITAL MEMORY | |
Max. Sampling Rate | 2GS/s in ETS – 50MS/s in Single Shot Mode on each channel (9 bits) |
Memory Depth | 2500 points/channel |
Memory Capacity | 2MB for storing various types files: trace, text, configuration, image files |
GLITCH Mode | Duration ≥ 20ns – 1,250 MIN Max pairs |
Display Modes | Envelope, Averaging (factors 2 to 64) and XY (vector) |
OTHER FUNCTIONS | |
Math Functions | Channel inversion,, +, -, x, / and (adjustable scaling) |
Automatic Measurement | 18 time, level, phase measurements |
Multimeter Mode | 2 channels, 8000 counts + Min and Max bargraph – TRMS – graphic recording of 2700 measurements (5 min to 31 days) |
AC, DC, AC+DC Voltages | 600mV to 600VRMS, 800mV to 800VDC: accuracy 2% R + 20cts Bandwidth 50kHz |
Active Power and PF | Single phase-Balanced 3 phase, with or without Neutral, simultaneous display of current |
Resistance, Temperature, Capacitance, Frequency, Speed Rotation and Diode Test | |
Harmonic Analyzer Mode | |
Multi-Channel Analysis | 2 channels, 31 orders, fundamental from 40 to 450Hz |
GENERAL FEATURES | |
Interface | Isolated USB, SX-Metro software included |
Batteries | 6 LR6 or 6 AA Rechargeable 9.6V NiMH battery pack, External charger |
Charging Time | External power adapter, 98 to 264VAC (50/60Hz) 2hrs 30min when OFF |
Battery life | Up to 8hrs 30min |
Dimensions (L x W x H) | 8.43 x 4.33 x 2.24” (214 x 110 x 57mm) |
Weight | 2.65lbs. (1.2kg) |
Altitude Operating | 2000m (6560ft) |
Operating Temperature | 32° to 104°F (0 to 40°C) ≤80% RH |
Storage Temperature | -4° to 140°F (-20 to 60°C) |
IP Rating | IP54 per IEC 60529 |
Safety | IEC/EN 61010-1 (1000V CAT II; 600V CAT III), IEC 1326-1 CE |
MN251T | MN379T | |
ELECTRICAL | ||
Nominal Range | 200A | 5A / 100A |
Measurement Range | 0.5 to 240A | 0.005 to 6A; 0.1 to 120A |
Accuracy | 3% of Reading @ 5A; 1% of Reading @ 200A | 1% of Reading @ 5A; 1% of Reading @ 100A |
Phase Shift | ≤2.5° @ 20A / ≤2.5° @ 100A | ≤4° @ 5A / ≤2.2 @ 100A |
Overload | 240A for 10 min ON, 30 min OFF | |
Frequency Range | 40 to 10kHz | |
Limit Operating Conditions | 200A permanently to 1kHz; Derating above 3kHz: 200A x (1/0.333F), F in kHz | |
Working/Common Mode Voltage | 600Vrms | |
Output Termination | 10ft (~3m) BNC Lead | |
Output Signal | 1mV/AAC (200mV @ 200A) | 200mV/A AC (1V @ 5A) & 10mV/A AC (1V @ 100A) |
MECHANICAL | ||
Operating Temperature | 14° to 131°F (-10° to 55°C) | |
Storage Temperature | -40° to 158°F (-40° to 70°C) | |
Operating Relative Humidity | 10 to 35°C (50 to 95°F) 85% RH (without roll-off above 35°C (95°F) | |
Jaw Opening | 0.83" (21mm) | |
Maximum Conductor Size | 0.78" (20mm) | |
Dimensions | 5.47 x 2.00 x 1.18" (139 x 51 x 30mm) | |
Weight | 6.5 oz (180g) | |
Polycarbonate Material | Polycarbonate with fiberglass charge, UL94 V0 | |
SAFETY | ||
Electrical | EN 61010-2-32 | |
Double Insulation | Yes | |
CE Mark | Yes |
3000-14-1-1 | 3000-24-1-1 | |
ELECTRICAL | ||
Range | 3000A | |
Signal Output | 1mV/A | |
Frequency Range | 10Hz to 20kHz with current derating | |
Influence Of Conductor Positioning | 1.5% typical, 3% max | |
Influence Of Conductor Positioning In Sensor Against Handle | 4% typical, 6% max | |
External Conductor Influence | 35dB to 40dB on contact | |
Power Source | 9V Alkaline battery (included) | |
MECHANICAL | ||
Sensor Diameter | Ø 0.2 (5mm) | |
Sensor Length | 14" (~355mm) | 24" (~609mm) |
Max Conductor Size (DIA) | 4.94" (~100mm) | 8" (~190mm) |
Connection Cable Length | 10ft (~3.04M) | |
Drop Test | Per IEC 68-2-32 | |
Vibration | Per IEC 68-2-6 | |
Mechanical Shock | Per IEC 68-2-27 | |
Weatherproofing | IP 50 | |
ENVIRONMENTAL | ||
Operating Temperature Range | 14° to 131°F (-10° to +55°C) | |
Storage Temperature Range | -40° to 158°F (-40° to +70°C) | |
Altitude | Operating: 0 to 6560ft (2000m), working voltage derating above; Non-operating: 0 to 39370ft (12,000m) | |
SAFETY | ||
Safety Rating | EN 61010, 1000V CAT III; 600V CAT IV |
Write Your Own Review
- Field Troubleshooting
- Education
- Design verification