MN02 is the ideal complement for any multimeter to measure AC currents in low-power secondary or industrial applications. When used with an AC Ammeter, it allows you to directly read the current measured when the probe is clamped around one of the carrying conductors.
ELECTRICAL | |
Range | 100A |
Measurement Range | 50mA to 100A (1Ω load) 50mA to 90A (10Ω load) |
Accuracy in % | ≤ 1% Reading ± 0.02A (1Ω load) ≤ 1.5% Reading ± 0.01A (10Ω load) |
Phase Shift | Not specified |
Output Signal | 1mA/A from 1Ω to 10Ω |
Load Impedance | ≤10Ω |
Maximum Currents | 1 < 150A permanent from 48Hz to 500Hz |
Influence of Temperature | ≤ 0.2% per 10˚K |
Influence of Adjacent Conductor | ≤ 2mA/A at 50Hz |
Influence of Adjacent Conductor Position in Jaws | ≤ 0.1% at 50/60Hz |
Influence of Frequency | ≤ 2% from 65Hz to 500Hz |
Maximum Output Voltage (secondary open) | ≤ 30V |
MECHANICAL | |
Operating Temperature | 14° to 122°F (-10° to +50°C) |
Storage Temperature | -40° to 176°F (-40° to +80°C) |
Operating Relative Humidity | 0 to 85% RH decreasing linearly above 35°C |
Operating Altitude | 0 to 2000m |
Casing Protection Rating (weatherproofing) | IP 40 (IEC 529) |
Drop | 4.92 ft (1.5m) (IEC 68-2-32) |
Shock Protection | 3.52 oz (100g)/6ms/half-period (IEC 68-2-27) |
Self-extinguishing Capability | casing UL94 V2 |
Vibration Resistance | IEC 68-2-6 |
Dimensions | 4.43 x 1.48 x 1.02" (112.5 x 37.5 x 26mm) |
Weight | 6.5 oz (180g) |
SAFETY | |
Electrical | EN61326-1, 300V CAT IV, 600V CAT III, Pollution Degree 2 |
Double Insulation | Yes |
CE Mark | Yes |
(1) Conditions of reference: 18°C to 28°C, 20 to 75% RH, external magnetic field <40 A/m, 48 to 65 Hz sine wave, distortion factor less than 1%, no DC component, no external current carrying conductor, test sample centered. Load impedance 1Ω or 10Ω.
Write Your Own Review