AEMC 514 Clamp-On Meter

SKU
2117.70_
Manufacturer:
AEMC
AEMC

Key Features:

  • Standard size, full function clamp-on meter
  • 1000AAC/DC current measurements
  • 750VAC/1000VDC volt measurements
  • TRMS measurements
  • Resistance measurement to 4000Ω
  • Continuity with beeper below 40Ω
  • Frequency measurements from V and A
  • Diode test
  • 1ms Peak function for fast capture of signals
  • Hold function to "freeze" readings
  • Push-button for easy ADC zeroing
  • Large easy-to-read 4000-count display
  • 42-segment analog bargraph
  • Includes test leads and soft carrying case
Product Options:
$224.00

Secured and trusted checkout with

Updated Operating Temperature Specification:

-14° to 122°F (-25 to 50°C), 80% RH, non-condensing

      The Clamp-on Meter Model 514 is a general purpose professional clamp-on meter that measures up to the toughest standards. It is built into a rugged mechanical case and is designed using quality polycarbonate materials. This meter offers a complete set of measurement ranges and is in compliance with international safety and quality standards to ensure a professional and reliable measuring tool. The Model 514 is auto-ranging and provides the best measurement range and resolution for troubleshooting. It has a high resolution 40A range.

      The Model 514 measures AC Amps, AC Volts, DC Volts, Ohms, Continuity (with beeper), Frequency (from V or A) and has a Diode Test function. The Model 514 also uses Hall sensor technology that provides both DC and AC current measurements to 1000A. The Model 514 is sized for a comfortable, one-handed operation. This model is True RMS sensing responding to distorted signal electrical systems. The jaw opening for the Model 514 is 1.575" (40mm).

MODELS

511

512 TRMS

514 TRMS

AC Current (Auto-Ranging)

0.05 to 1000A

0.05 to 1000Arms

0.05 to 1000Arms

Resolution

0.01A, 0.1A and 1A

0.01A, 0.1A and 1A

0.01A, 0.1A and 1A

Accuracy      50 to 60Hz

60 to 500Hz

1.9% of Reading ± 5cts

1.9% of Reading ± 5cts

1.9% of Reading ± 5cts

1.9% of Reading ± 5cts

1.9% of Reading ± 5cts

2.5% of Reading ± 5cts

AC Voltage (Auto-Ranging)

0.5 to 750V

0.5 to 750Vrms

0.5 to 750Vrms

Resolution

0.1V and 1V

0.1V and 1V

0.1V and 1Vrms

Accuracy    60 to 500Hz

1.2% of Reading ± 5cts

1.2% of Reading ± 5cts

1.5% of Reading ± 5cts

Input Impedance

10MΩ

10MΩ

10MΩ

DC Current (Auto-Ranging)

1A to 1000A

Resolution

0.01A, 0.1A and 1A

Accuracy

±2.5%  of Reading ± 10cts

DC Voltage (Auto-Ranging)

0.2 to 1000V

0.2 to 1000V

0.2 to 1000V

Resolution

0.1V and 1V

0.1V and 1V

0.1V and 1Vrms

Accuracy

0.75% of Reading ± 2cts

0.75% of Reading ± 2cts

1% of Reading ± 2cts

Input Impedance

10MΩ

10MΩ

10MΩ

Resistance

0.2 to 4000Ω

0.2 to 4000Ω

0.2 to 4000Ω

Accuracy

1% of Reading ± 2cts

1% of Reading ± 2cts

1% of Reading ± 2cts

Max Test Voltage

3VDC

3VDC

3VDC

Diode Test

0.6mA

0.6mA

1.7mA

Open Circuit Voltage

3VDC

3VDC

3VDC

Continuity

<40Ω

<40Ω

<40Ω

Max Test Voltage

3VDC

3VDC

3VDC

Frequency (Auto-Ranging)

CURRENT INPUT

Range                  4kHz

10kHz

 

1Hz Resolution

 

1Hz Resolution

 

1Hz Resolution

10Hz Resolution

Accuracy    20Hz to 10kHz

0.1% of Reading ± 1ct

0.1% of Reading ± 1ct

0.1% of Reading ± 1ct

Min Input Signal     4kHz

10kHz

2Arms

2Arms

2Arms

5Arms

VOLTAGE INPUT

Range                   4kHz

10kHz

 

1Hz Resolution

 

1Hz Resolution

 

1Hz Resolution

10Hz Resolution

10Hz Resolution

10Hz Resolution

Accuracy 10Hz to 10kHz

0.1% of Reading ± 1ct

0.1% of Reading ± 1ct

0.1% of Reading ± 1ct

Min Input Signal    4kHz

5Vrms

5Vrms

5Vrms

10kHz

5Vrms

5Vrms

10Vrms

Power Source

9V Alkaline battery (included)

ENVIRONMENTAL

Operating Temperature

32° to 104°F (0° to 40°C)

< 80% RH, non-condensing

32° to 104°F (0° to 40°C)

< 80% RH, non-condensing

*-14° to 122°F (-25° to 50°C),

80% RH, non-condensing

Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
  • Commercial, industrial, residential and HVAC troubleshooting
  • Power panel, junction box and battery bank monitoring
  • AC or DC motor testing
  • Power plant troubleshooting
  • Electrical testing and troubleshooting on non-linear loads, such as adjustable speed drives and computers