www.instrumentation2000.com C/O Industrial Process Measurement, Inc. 3910 Park Ave, Unit 7 Edison, NJ 08820 USA (732) 632-6400
Amprobe DM-III Flex Power Quality Analyzer and Recorder - DISCONTINUED Manufacturer: Amprobe
Part Number: DM-III-MULTITEST
Product Details The Amprobe DM-III is an advanced single or 3 pahse power analyzer and recorder that includes all accessories to troubleshoot today's power circuits. The DM-III Flex model includes 3000 amp flexible current transformers.
Specifications AC Voltage 600 V AC Currrent 1000 A 3000 A Optional CT’s 1000 A, 3000 A 100 A Harmonics THD, DC to 49th Power W, VAR, VA Energy Wh, WARh, VAh Voltage anomalies Sag/surge Power factor 0.00 +/- 1.00 Frequency 50 / 60 Hz Phase sequence 1-2-3 Insulation tester 50 V, 100 V, 250 V, 500 V, 1000 V Ground resistance Reisitance & resistivity
Specifications Supplied current transducer: AM-FLEX33 3000A Flexible 7 internal diameter CT +/-(0.5% Rdg + 2 LSD AC Current: DM-CT-100:0.5A to 100A / DM-CT-HTA:5 - 1000A /AM-FLEX33: selectable: 5 – 1000A or 15 - 3000A +/-(0.5% Rdg + 2 LSD) AC Voltage including sags and surges: 0 - 600V +/-(0.5% Rdg + 2 LSD Harmonics: THD, DC and individual up to 49th +/-(0.5% Rdg + 2 LSD) Power: Working (W), reactive (VAR) and apparent (VA) +/-(1.0% Rdg + 2 LSD Energy: Working (kWh), reactive (VARh) and apparent (VAh) +/-(1.0% Rdg + 2 LSD) Peak demand: KW +/-(1.0% Rdg + 2 LSD) Power factor: 0.00 – 1.00 Frequency measurement: 57 to 63.6 Hz at 60Hz fundamental 47 to 53 Hz at 50Hz fundamental +/-(1.0% Rdg + 2 LSD) Phase sequence: 1 - 2 - 3 Co-generation: Computes incoming and outgoing energy Selectable fundamental frequencies: 50/60 Hz Available recording time: Several hours to several years depending on setup Insulation resistance with 50V DC test voltage: 0.01-19.99, 49.9 +/- (2% reading + 2 digits) 49.9 - 99.9MΩ +/- (5% reading + 2 digits) Insulation resistance with 100V DC test voltage: 0.01-19.99, 99.9 +/- (2% reading + 2 digits) 99.9 - 199.9MΩ +/- (5% reading + 2 digits) Insulation resistance with 250V DC test voltage: 0.01-19.99, 199.9, 249 +/- (2% reading + 2 digits) 249 - 499MΩ +/- (5% reading + 2 digits) Insulation resistance with 500V DC test voltage: 0.01-19.99, 199.9, 499 +/- (2% reading + 2 digits) 499 - 999 MΩ +/- (5% reading + 2 digits) Insulation resistance with 1000V DC test voltage: 0.01-19.99, 199.9, 999 +/- (2% reading + 2 digits) 999 - 1999 MΩ +/- (5% reading + 2 digits) Low resistance (without timer): 0.01-19.99, 99.9Ω+/- (2% reading + 2 digits) Low resistance (with timer): 0.01-9.9Ω+/- (2% reading + 2 digits) Ground resistance: 0-19.99, 199.9, 1999 Ω +/- (5% reading + 3 digits) Ground resistivity: 0.6- 125.6 Ω 0.125-1.256, 19.99, 199.9 kΩ +/- (5% reading + 3 digits)
The store will not work correctly when cookies are disabled.
JavaScript seems to be disabled in your browser. For the best experience on our site, be sure to turn on Javascript in your browser.
We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more .
Allow Cookies