The compact and handy Fluke laser distance meters were designed for indoor and limited outdoor applications. All three models are simple to operate, with the Fluke durability and quality you expect. And, with specific function buttons, different tasks can be completed quickly and easily.
The extra bright laser is clearly visible so you can always see your targeting point even if the target object is in a hard-to-reach spot, or a long distance away. These units have a large LCD screen and buttons positioned for one-handed measurements.
Specifications
Distance Measurement
Typical measuring tolerance 1
±1.0 mm 3
Maximum measuring tolerance 2
±2.0 mm 3
Range At Leica Target Plate GZM26
100 m / 330 ft
Typical range 1
80 m / 260 ft
Range at unfavorable condition 4
60 m / 195 ft
Smallest unit displayed
6 / 30 / 60 mm (10 / 50 / 100 m)
Ø Laser point at distances
6 / 30 / 60 mm (10 / 50 / 100 m)
Tilt Measurement
Measuring tolerance to laser beam 5
±0.2°
Measuring tolerance to housing 5
±0.2°
Range
360°
General
Laser cass
2
Laser type
635 nm, < 1 mW
Protection class
IP54
Automatic laser off
After 90 seconds
Automatic power off
After 180 seconds
Battery life (2 x AAA) 1.5 V NEDA 24A/IEC LR03
Up to 5,000 measurements
Size (L x W x D)
127 x 56 x 33 mm
Weight (with batteries)
158 g
Temperature range Storage operation
-25°C to +70°C (-13°F to +158°F)
-10°C to +50°C (14°F to +122°F)
Calibration cycle
Tilt and compass
Maximum altitude
3000 m
Maximum relative humidity
85% at 20°F to 120°F (-7°C to 50°C)
Safety
IEC Standard No. 61010-1:2001
EN60825-1:2007 (Class II)
EMC
EN 55022:2010
EN 61000-4-3:2010
EN 61000-4-8:2010
1. Applies for 100% target reflectivity (white painted wall), low background illumination, 25°C. 2. Applies for 10 to 500% target reflectivity, high background illumination, -10°C to +50°C. 3. Tolerances apply from 0.05 m to 10 m with a confidence level of 95%. The maximum tolerance may deteriorate to 0.1 mm/m between 10 m to 30 m and to 0.15 mm/m for distances above 30 m. 4. Applies for 100% target reflectivity, background illumination between 10'000 lux and 30'000 lux. 5. After user calibration. Additional angle related deviation of ±0.01° per degree up to ±45° in each quadrant. Applies at room temperature. For the whole operating temperature range the maximum deviation increases by ±0.1°.