The Fluke T6-1000 PRO Electrical Tester measures voltage up to 1000 V ac and current up to 200 A ac, all through the open fork and without test lead contact to live voltage. Simply connect the black lead to ground with the included heavy-duty alligator clip, slide the wire into the open fork and see both voltage and current simultaneously. On wires up to AWG 4/0 (120 mm2), carrying as much as 200 A and 1000 V ac. Even with gloves on. It will change how you do your job.
Specifications
Function
FieldSense ac voltage
Requires test leads
No
Range
1000 V
Resolution
1 V
Accuracy
±(3 % + 3 counts) 45 Hz - 66 Hz[1] [2]
FieldSense ac current
Requires test leads
No
Range
200.0 A
Resolution
0.1 A
Accuracy
±(3 % + 3 counts) 45 Hz - 66 Hz
FieldSense frequency (Hz)
Requires test leads
No
Range
45 Hz – 66 Hz
Resolution
1 Hz
Accuracy
±(1 % + 2 counts)
Volts ac
Requires test leads
Yes
Range
1000 V
Resolution
1 V
Accuracy
±(1.5 % + 2 counts) 45 Hz - 66 Hz
Volts dc
Requires test leads
Yes
Range
1000 V
Resolution
1 V
Accuracy
±(1 % + 2 counts)
Resistance
Requires test leads (all ranges)
Yes
Range
2000 Ω
Resolution
1 Ω
Range
20.00 kΩ
Resolution
0.01 kΩ
Range
100.0 kΩ
Resolution
0.1 kΩ
Accuracy (all ranges)
±(1 % + 2 counts)
Accuracy[1]: ± ( [ % of reading] + [number of least significant digits] ). Accuracy is specified for 1 year after calibration, at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC conversions are ac-coupled, RMS responding.
Accuracy[2]: FieldSense specified from 16V to 1000V.
IEC/EN 61326-1: Portable
General Specifications
Calibration
1-year calibration cycle
Dimensions
61 mm x 259 mm x 43 mm
Weight
0.35 kg (0.78 lb)
Fork opening
17.8 mm (0.7”)
Temperature Operating: Storage:
-10 °C to +50 °C (14 °F to 122 °F) -30 °C to +60 °C (-22 °F to +140 °F)
Altitude Operating: Storage:
2,000 m (6,562 feet) 10,000 m (32,808 feet)
Relative Humidity
0 % to 90 %, 5 °C to 30 °C (41 °F to 86 °F) 0 % to 75 %, 30°C to 40 °C (86 °F to 104 °F) 0 % to 45 %, 40°C to 50 °C (104 °F to 122 °F)
Battery Type: Life:
2x AA (IEC LR6) 360 hour continuous, typical is 200 hour using the FieldSense function
Temperature coefficient
0.1 x (specified accuracy) / °C for <18°C or >28 °C (< 64.4 °F or > 82.4 °F)
Safety General: Measurement T6-1000 PRO:
IEC 61010-1: Pollution Degree 2 IEC 61010-2-032: CAT IV 600 V / CAT III 1000 V
Electromagnetic Compatibility
IEC/EN 61326-1: Portable