The FLIR TG165-X helps users see the hot and cold spots that can signify electrical faults, mechanical break-downs, or air and water leaks. This all-in-one, non-contact measurement and imaging tool shows temperature anomalies on screen, allowing for efficient inspection and identifying the source of problems faster than with a single-spot IR thermometer. Users can view components clearly and even read labels thanks to FLIR patented MSX image enhancement, which adds visual details to full thermal images. The bullseye laser guarantees you’re always targeting the right component for measurement while easy-to-use buttons and settings help you complete the job quickly and easily. With internal storage for up to 50,000 images and a rechargeable Li-ion battery, the FLIR TG165-X is ready to use right out of the box.
Specifications
Overview
Accuracy
50°C to 100°C (122°F to 212°F), acc. ±1.5°C (±3°F); 0°C to 50°C (32°F to 122°F) and 100°C to 300°C (212°F to 572°F), acc. ±2.5°C (±5°F); -25°C to 0°C (-13°F to 32°F), acc. ±3°C (±7°F)
Display Technology
TFT
Field of view (FOV)
51° × 66°
IR Resolution
80 × 60 pixels
Laser
Class 1
Laser Pointer
Indicating the size of the measurement area
Object Temperature Range
-25°C to 300°C (-13°F to 572°F)
Resolution
2 MP (1600 × 1200 pixels)
Thermal Sensitivity/NETD
<70 mK
Size [L × W × H]
210 × 64 × 81 mm (8.3 × 2.5 × 3.2 in)
Connections & Communications
Interface
USB 2.0
Storage Media
eMMC 4 GB
USB
USB Type-C: data transfer/power
USB - Standard
USB Type-C High Speed; data transfer/power
Environmental
Drop
Designed for 2 m (6.56 ft)
EMC
EN 61000-6-3/EN 61000-6-2/FCC 47 CFR Part 15 Class B
Emissivity Correction
Yes: 4 pre-set levels with custom adjustment of 0.1–0.99
Encapsulation
IP54 (IEC60529)
Humidity (Operating and Storage)
0–90% relative humidity (RH) (0°C to 37°C (32°F to 98.6°F)); 0–65% RH (37°C to 45°C (98.6°F to 113°F)); 0–45% RH (45°C to 55°C (113°F to 131°F ))
Magnetic fields
EN 61000-4-8 class 3
Operating Temperature Range
-10°C to 45°C (14°F to 113°F)
Radio Spectrum
ETSI EN 300 328/FCC Part 15.249/RSS-247 Issue 2/EN 301 489-1:2011/EN 301 489-17:2009
Safety
CE/CB/EN61010/UL
Shock
25 g (IEC 60068-2-27)
Storage Temperature Range
-30°C to 55°C (-22°F to 131°F)
Tripod Mounting
UNC ¼″-20
Vibration
2 g (IEC 60068-2-6)
Environmental Safety
REACH Regulation EC 1907/2006; RoHS2 Directive 2011/65/EC; WEEE Directive 2012/19/EC; JIS C 6802:2011 laser directive (ongoing); IEC 60825-1 class I laser directive; FDA laser
The store will not work correctly when cookies are disabled.
We use cookies to make your experience better.To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies.Learn more.