Ametek JOFRA CTC-652 Dry Block Calibrator (28 to 650 C) Product Details The Ametek JOFRA CTC-652 is a quick, reliable dry block temperature calibrator that ranges from 28 to 650°C (82 to 1202°F).
Specifications Temperature Temperature Range @ Ambient 23°C/73°F. . . . . . . . . . . . . . 28 to 650°C / 82 to 1202°F @ Ambient 0°C/32°F. . . . . . . . . . . . . . . . .5 to 650°C / 41 to 1202°F Accuracy * CTC-652 With Internal Reference Sensor @ 650°C / 1202°F. . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±0.65°C /±1.17°F @ 400°C / 752°F. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±0.60°C /±1.08°F @ 200°C / 392°F. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±0.50°C /±0.90°F CTC-652 With External Reference Sensor STS-200-A-970 @ 650°C / 1202°F. . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±0.45°C /±0.81°F @ 400°C / 752°F. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±0.40°C /±0.72°F @ 200°C / 392°F. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±0.35°C /±0.63°F Stability CTC-652 ** . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .±0.05°C / ±0.09°F Radial Homogeneity (difference between holes) CTC-652 @ 650°C / 1202°F . . . . . . . . . . . . . . . . . . . . . .0.08°C / 0.14°F CTC-652 @ 400°C / 752°F. . . . . . . . . . . . . . . . . . . . . . 0.03°C / 0.054°F Influence From Load Ø6mm 28 to 650°C / 82 to 1202°F With Internal Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . 0,1°C / 0.18°F With External Reference . . . . . . . . . . . . . . . . . . . . . . . 0,03°C / 0.054°F Settings Resolution. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 or 0.1 or 0.01 Units. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .°C or °F or K Heating Time CTC-652 . . . . . . . . . . . .23 to 650°C / 73 to 1202°F. . . 33 minutes Cooling Time CTC-652. . . . . . . . . 650 to 100°C / 1202 to 212°F. . . 48 minutes CTC-652. . . . . . . . . . . .100 to 50°C / 212 to 122°F. . . 25 minutes Time to Stability (typical) CTC-652. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 minutes
Mains Power Voltage **** . . . . . . . . . . . . . 115 V (103-127) / 206 V (180-254) Max Power Consumption. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1150 VA Frequency, US deliveries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Hz ±3 Frequency, non US deliveries. . . . . . . . . . . . . . . 50 Hz ±3, 60 Hz ±3 Physical Specifications Dimension L x W x H. . .248x148x390 mm / 9.76x5.83x15.35 in Weight CTC-652. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9.0 kg / 19.8 lb Immersion Depth CTC-652. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190 mm / 7.48 in Well Diameter CTC-652. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 mm / 1.02 in Insert Dimensions (diameter x length) CTC-652. . . . . . . . . . . . . . . . . 25.7 mm x 200 mm / 1.01 x 7.874 in Electrical Switch Input (dry contact) Test Voltage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Maximum 14 VDC Test Current. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maximum 1 mA Digital Interface USB 2.0 Environmental Operating Temperature 0 to 50°C / 32 to 122°F Storage Temperature -20 to 50°C / -4 to 122°F Humidity 5 to 90% Rh, non-condensing Protection Class IP-10
External Reference Sensor STS-200-A-970. . . . . . . . . . . . . . . . . . . . . . .0 to 700°C / 32 to 1292°F Accuracy Hysteresis (@ 0°C / 32°F) . . . . . . . . . . . . . . . . . . . . . . 0.01°C / 0.018°F Long Term Stability (@ 0°C / 32°F) *** . . . . . . . 0.016°C / 0.029°F Repeatability. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.002°C/ 0.0036°F Sensing element Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pt100 Response Time STS-200-A-970: t0.5 (50%) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 sec. STS-200-A-970: t0.9 (90%) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 sec. Dimensions Diameter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 mm / 0.157 in Length. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241 mm / 9.29 in Max. height over calibrator top. . . . . . . . . . . . . . . . .35 mm / 1.38 in
Please note: All specifications are given with an ambient temperature 23°C / 73.4°F ± 3°C / 5.9°F and specified at 115 V/230 V.* ) In lower 40 mm incl. Stability, Uniformity, 12-month drift (typical), Hysteresis, Resolution, Load (Max 6 mm) and calibration laboratory uncertainty.** ) Measured after the stability indicator has been on for 10 minutes. Measuring time is 30 minutes.*** ) Stability when exposed to maximum temperature for 100 hours. Stability will depend on actual use of the probe.**** ) 103V-127VAC/206-254VAC 47-63 Hz for full temperature range. At mains voltage below 103VAC/206VAC maximum temperature will be reduced.