| Ti401 PRO | Ti480 PRO | TiX501 | TiX580 |
Key Features | |
Infrared resolution | 640 x 480 (307,200 pixels) |
SuperResolution | No | Yes, in software. Captures and combines 4x the data to create a 1280 x 960 image | No | Yes, in software. Captures and combines 4x the data to create a 1280 x 960 image |
IFOV with standard lens (spatial resolution) | 0.93 mRad, D:S 1065:1 |
Field of view | 34 °H x 24 °V |
Minimum focus distance | 15 cm (approx. 6 in) |
MultiSharp Focus | No | Yes, focused near and far, throughout the field of view | No | Yes, focused near and far, throughout the field of view |
LaserSharp Auto Focus | Yes, for consistently in-focus images. Every. Single. Time |
Laser distance meter | Yes, calculates distance to the target for precisely focused images and displays distance on screen |
Advanced manual focus | Yes |
Wireless connectivity | Yes, to PC, iPhone® and iPad® (iOS 4s and later), Android™ 4.3 and up, and WiFi to LAN (where available) |
Fluke Connect app compatible | Yes*, connect your camera to your smartphone, and images taken automatically upload to the Fluke Connect app for saving and sharing |
Fluke Connect Assets | Through the desktop, assign images to assets, easily compare measurement types in one location and create reports. | Future**, Automatically assign images to assets, easily compare measurement types in one location and create reports through a cloud-based system. |
Fluke Connect instant cloud upload | Yes*, connect your camera to your building’s WiFi network, and images taken automatically upload to the Fluke Connect system for viewing on your smartphone or PC |
Fluke Connect instant server upload | Yes** | Yes** | Yes** | Yes** |
IR-Fusion technology | Yes, adds the context of the visible details to your infrared image |
Ruggedized touchscreen display | 3.5 inch (landscape), 640 x 480 LCD | 5.7 inch (14.4 cm) landscape 640 x 480 LCD |
Ergonomic design | Pistol-grip design for one-handed use | 240 ° rotatable (articulating) lens |
Thermal sensitivity (NETD)** | ≤ 0.075 °C at 30 °C target temp (75 mK) | ≤ 0.05 °C at 30 °C target temp (50 mK) | ≤ 0.075 °C at 30 °C target temp (75 mK) | ≤ 0.05 °C at 30 °C target temp (50 mK) |
Level and span | Smooth auto and manual scaling |
Touchscreen adjustable level/span | Yes. Span and level can be easily and quickly set by simply touching the screen |
Fast auto toggle between manual and auto modes | Yes |
Fast auto-rescale in manual mode | Yes |
Minimum span (in manual mode) | 2.0 °C (3.6 °F) |
Minimum span (in auto mode) | 3.0 °C (5.4 °F) |
Built-in digital camera (visible light) | 5MP |
Frame rate | 60 Hz or 9 Hz versions |
Laser pointer | Yes |
LED light (torch) | Yes |
Digital Zoom | No | 2x and 4x | 2x | 2x, 4x, 8x |
Data storage and image capture |
Extensive memory options | Removable 4 GB micro SD memory card, 4 GB internal flash memory, save to USB flash drive capability, upload for permanent storage |
Image capture, review, save mechanism | One-handed image capture, review, and save capability | Yes, edit and analyze captured images on camera |
Image file formats | bmp, jpeg, is2 | bmp, jpeg, is2, is3, AVI | bmp, jpeg, is2, is3, AVI | bmp, jpeg, is2, is3, AVI |
Memory review | Thumbnail and full screen review |
Software | Full analysis and reporting software with access to the Fluke Connect system |
Analyze and store radiometric data on a PC | Yes |
Export file formats with Fluke Connect software | Bitmap (.bmp), GIF, JPEG, PNG, TIFF |
Voice annotation | 60 seconds maximum recording time per image; reviewable playback on camera, optional Bluetooth headset available but not required |
IR-PhotoNotes | Yes - 2 images | Yes - 5 images | Yes - 2 images | Yes - 5 images |
Text annotations | Yes. Including standard shortcuts as well as user programmable options |
Video recording and formats | No | Standard and radiometric | Standard | Standard and radiometric |
Remote control operations | Remote display through Fluke Connect | Remote display and control operation through Fluke Connect | Remote display through Fluke Connect | Remote display and control operation through Fluke Connect |
Auto capture (temperature and interval) | No | Yes | No | Yes |
MATLAB® and LabVIEW® tool boxes | – | Integrate camera data, infrared video and images into software to support R&D analysis |
Battery |
Batteries (field-replaceable, rechargeable) | Two lithium ion smart battery packs with five-segment LED display to show charge level |
Battery life | 2-3 hours per battery (actual life varies depending on settings and usage) |
Battery charging time | 2.5 hours to full charge |
Battery charging system | Two-bay battery charger or in-imager charging. Optional 12 V automotive charging adapter |
AC operation | AC operation with included power supply (100 V AC to 240 V AC, 50/60 Hz) |
Power saving | User selectable sleep and power off modes |
Temperature measurement |
Temperature measurement range (not calibrated below -10 °C) | -20°C to +650°C (-4°F to +1,202°F) | -20°C to +1,000°C (-4°F to 1,832°F) | -20°C to +650°C (-4°F to +1,202°F) | -20°C to +1,000°C (-4°F to 1,832°F) |
Accuracy | ± 2 °C or 2 % (at 25 °C nominal, whichever is greater) |
On-screen emissivity correction | Yes (both value and table) |
On-screen reflected background temperature compensation | Yes |
On-screen transmission correction | Yes |
Line temperature graph | No | Yes | No | Yes |
Color palettes |
Standard palettes | 9: Rainbow, Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted | 8: Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted |
Ultra Contrast palettes | 9: Rainbow, Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted | 8: Ironbow Ultra, Blue-Red Ultra, High Contrast Ultra, Amber Ultra, Amber Inverted Ultra, Hot Metal Ultra, Grayscale Ultra, Grayscale Inverted Ultra |
Smart lenses |
Macro–25 micron lens: 25 MAC2 | Yes |
2 x telephoto lens: TELE 2 | Yes |
4 x telephoto lens: TELE4 | Yes |
Wide angle lens: WIDE 2 | Yes |
General specifications |
Color alarms (temperature alarms) | High temperature, low temperature, and isotherms (within range) |
Infrared spectral band | 7.5 μm to 14 μm (long wave) |
Operating Temperature | -10 °C to +50 °C (14 °F to 122 °F) |
Storage Temperature | -20 °C to +50 °C (-4 °F to 122 °F) without batteries |
Relative humidity | 10 % to 95 % non-condensing |
Center-point temperature measurement | Yes |
Spot temperature | Hot and cold spot markers | Hot and cold spot markers, individually enabled |
User-definable spot markers | No | 3 user-definable spot markers | 2 user-definable spot markers | 3 user-definable spot markers |
User defined measurement boxes | 1 expandable-contractible measurement box with MIN-MAX-AVG temp display | Up to 3 expandable-contractible measurement box with MIN-MAX-AVG temp display | 1 expandable-contractible measurement box with MIN-MAX-AVG temp display | 3-Expandable-contractible measurement box with MIN-MAX-AVG temp display |
Hard Case | Rugged, hard carrying case; soft transport bag | Rugged, IP67 rated, airtight hardcase with custom foam insert |
Safety | IEC 61010-1: Overvoltage category II, Pollution Degree 2 |
Electromagnetic compatibility | IEC 61326-1: Basic EM environment. CISPR 11: Group 1, Class A |
Australian RCM | IEC 61326-1 |
US FCC | CFR 47, Part 15 Subpart B |
Vibration | 0.03 g2/Hz (3.8 g), 2.5 g IEC 60068-2-6 |
Shock | 25 g, IEC 68-2-29 |
Drop | Engineered to withstand 2 meter (6.5 feet) drop with standard lens | Engineered to withstand 1 meter (3.3 feet) drop with standard lens |
Size (H x W x L) | 27.7 cm x 12.2 cm x 16.7 cm (10.9 in x 4.8 in x 6.5 in) | 27.3 cm x 15.9 cm x 9.7 cm (10.8 in x 6.3 in x 3.8 in) |
Weight (battery included) | 1.04 kg (2.3 lb) | 1.54 kg (3.4 lb) |
Enclosure rating | IEC 60529: IP54 (protected against dust, limited ingress; protection against water spray from all directions) |
Warranty | Two-years (standard), extended warranties are available |
Recommended calibration cycle | Two-years (assumes normal operation and normal aging) |
Supported languages | Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish |
RoHS compliant | Yes |