The Fuji Electric PHL is an 18-channel recorder that displays data on a brilliant 5.7" TFT color LCD. The Fuji Electric PHL paperless recorder features a wide variety of display modes to allow users to view data as trends (horizontally or vertically), bar graphs, analog meters, digital/numeric output, totalized output, event summaries, and more. The PHL allows users to record up to 12 types of thermocouples, 5 types of RTDs, and DC voltage/current input on one unit.
Specifications
General specifications
Mounting method
Panel mount
Power supply voltage
100–240 V AC, 50/60 Hz
Power consumption
Approx. 47 VA (at 240 V AC)
Terminal
M3 screw terminal (Open collector outputs are D-sub connectors.)
Input section
Number of inputs
18 points
Measurement cycle
100 ms
Input signal
Thermocouple (type B, R, S, K, E, J, T, N, W, L, U, or PN) RTD (Pt100) DC voltage (50 mV, 500 mV, or 5 V) DC current (with shunt resister)
Burnout function
Provided as standard for thermocouple or RTD input
Display unit
Display
5.7" TFT color LCD (320 240 dots) with automatic display off function
Life of backlight
50,000 hours
Display contents
Trend, bar graph, digital display, event summery, historical trend, parameter, parameter setting, group, analog meter, scale, total data
Recording function
Storage medium
CompactFlash
Recording capacity
2 GB max.
Data saving cycle
Links to refreshment cycle of the trend display
Trend data
Maximum and minimum values are saved.
Event data
Alarm data and message data are saved.
Data format
ASCII (readable by Excel) Binary (not readable by Excel)
Storage capacity
Approx. 1.5 years' worth at a display refresh cycle of 30 seconds (ASCII, 9 channels, 256 MB CompactFlash)
Memory consumption
Displayed in bar graph Recording stops when the memory is full.
Calculation function
Difference between channels, F value, integration, square root extraction
Alarm
Number of settings
Up to 4 alarms for each channel
Alarm type
High/low limits
Indication
Alarm status is displayed on digital display when an alarm occurs. Histories are displayed in the alarm summary.
Relay contact output
10 points (option) *Not available for 18-inputs version.
Open collector output
18 points (option)
Performance
Indication accuracy
±(0.15% + 1 digit) of input range
Indication resolution
0.1°C
Reference junction compensation error
±0.5°C
Others
Memory backup
Parameter settings are saved to the internal nonvolatile memory. The clock is backed up by a built-in lithium battery. Trend data is stored in CompactFlash with no back-up.
Option
Alarm output/DI
10 relay outputs and 5 digital inputs (Not available for 18-inputs version.), or 18 open collector outputs and 5 digital inputs are added.
Communication
Ethernet or RS485 (MODBUS) interface with 18 alarm (open collector) outputs and 5 digital inputs
Accessories
Panel mount type
Data viewer software, parameter loader software, panel mounting bracket, noise filter for power cable, front panel packing, instruction manual (CD-R)
Portable type
Data viewer software, parameter loader software, power cable (2 m), noise filter for power cable, instruction manual (CD-R)
The store will not work correctly when cookies are disabled.
We use cookies to make your experience better.To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies.Learn more.