The Cal Test CT4071 allows safe, accurate measurement between two voltage points where neither point is referenced to ground. The CT4071 offers both a 50 MHz bandwidth and a 25 MHz bandwidth. The 50 MHz bandwidth is for the 200x, 500x, and 1000x attenuation settings and the 25 MHz bandwidth is for the 100x attenuation setting.
Includes:
• (2) High voltage hook probes, black & red
• (2) Alligator Clips, black & red
• (2) Sheathed 4 mm banana plug test leads, silicone jacketed, black & red
• Insulated BNC cable, 100 cm
• 9 V Power adapter included (CT3957)
Specifications
Electrical Characteristics
CT4071
Bandwidth (-3dB)
50 MHz for 200x/500x/1000x
25 MHz for 100x
Rise Time (probe only)
7 ns for 200x/500x/1000x
18 ns for 100x
Attenuation ratio
100x/200x/500x/1000x
Accuracy
±2%
Input Voltage:
Differential Input Voltage (DC + AC peak) @ 100x
±350 V
Differential Input Voltage (DC + AC peak) @ 200x
±700 V
Differential Input Voltage (DC + AC peak) @ 500x
±1750 V
Differential Input Voltage (DC + AC peak) @ 1000x
±3500 V
Absolute Maximum Rated Input Voltage (each side to ground)
2500 Vrms
Input Impedance
54 MΩ // 1.2 pF
Input Impedance (each side to ground)
27 MΩ // 2.3 pF
Output Voltage:
Swing
±8 V (driving 1 MΩ oscilloscope input)
Offset (typical)
±5 mV
Noise (typical)
2 mVrms
Source Impedance (Typ.)
50 Ω
Safety Specifications
IEC 61010-031 CAT II
Mechanical Characteristics
Weight
280 g
Dimensions
240 x 80 x 30 mm
BNC Cable Length
100 cm
Input Leads Length
55 cm
Environmental Characteristics
Operating Temp/Humidity
0°C to 50°C / Up to 85% RH
Storage Temp/Humidity
-30°C to 70°C / Up to 90% RH
Pollution Degree
Pollution Degree 2
The store will not work correctly when cookies are disabled.