Measure inductors, capacitors and resistors at DC or from 20 Hz to 300 kHz with BK Precision’s new 891 Bench LCR Meter. The 891 features a bin sorting function and frequency sweep function for fast and efficient grouping and characterization of components. Users can easily read vital parameters and measurements on the expansive 4.3” color display.
The 891 LCR Meter offers the most in user versatility with its compact 2U half-rack form factor allowing for the bench or rack mount installations. Even more, standard USB, GPIB and LAN interfaces augment productivity by enabling remote control abilities to carry out daily operations in an array of industries.
Specifications
Measurements
Series mode
Parallel mode
Primary
Secondary
Primary
Secondary
Capacitance
Cs
Q, D, Rs
Cp
Q, D, Rp, G
Inductance
Ls
Q, D, Rs
Lp
Q, D, Rp, G
Resistance
R
X
-
-
Conductance
-
-
G
B
Impedance
Z
θ
-
-
Admittance
-
-
Y
θ
DC Resistance
DCR
-
-
-
Enhanced Measurement Functions
Bin Sorting Comparator
Limit Setting Mode
Tolerance (TOL) value or absolute (ABS) value
Number of Bins
9 primary bins, 1 secondary bin, and 1 out-of-spec bin
Bin Counts
0 to 60000
Beep Warning
Off, pass with smart tone and fail
Measurement Trigger
Manual trigger
Display Format
Measurement, table, and histogram
Sweep
Frequency Range
20 Hz to 300 kHz
Sweep Modes
Linear and logarithmic
Sweep Points
Up to 300 points
Sweep Step
1, 2, 5, and 10 points/step
Parameters
Primary and secondary
Display Format
Graph and table
Measurement Parameters
MeasurementSpeed
Slow
800 ms/measurement
Fast
200 ms/measurement
Measurement Range
Range
Auto or Hold range
Test Signal
AC
Levels
0.5 Vrms and 1 Vrms selectable
Level Accuracy
5%
Output Impedance
100 Ω (nominal)
Frequency
20 Hz to 300 kHz
Resolution
0.01 Hz (20.00 Hz to 99.99 Hz)
0.1 Hz (100.0 Hz to 999.9 Hz)
1 Hz (1.000 kHz to 9.999 kHz)
100 Hz (100.0 kHz to 300.0 kHz)
Frequency Accuracy
± 0.1%
DC
Level Range
1 VDC
Level Accuracy
5%
Output Impedance
100 Ω (nominal)
Impedance Measurement(Z) Accuracy (1)
Impedance
Frequency
DC, 20 Hz – 1 kHz
1 kHz – 10 kHz
10 kHz– 100 kHz
100 kHz – 200 kHz
200 kHz – 300 kHz
0.1 Ω – 1 Ω
1% ± 1
1% ± 1
2% ± 1
5% ± 1
10% ±1
1 Ω – 100 Ω
0.5% ± 1
0.5% ± 1
1% ± 1
2% ± 1
4% ± 1
100 Ω – 1 kΩ
0.2% ± 1
0.2% ± 1
0.5% ± 1
0.5% ± 1
1% ± 1
1 kΩ – 10 kΩ
0.05% ± 1
0.2% ± 1
0.5% ± 1
1% ± 1
2% ± 1
10 kΩ – 100 kΩ
0.2% ± 1
0.2% ± 1
1% ± 1
1% ± 1
2% ± 1
100 kΩ – 1 MΩ
0.5% ± 1
0.5% ± 1
2% ± 1
3% ± 1
4% ± 1
1 MΩ – 10 MΩ
2% ± 1
2% ± 1
5% ± 1
5% ± 1
10% ± 1
10 MΩ – 20 MΩ
4% ± 1
5% ± 1
NA
NA
NA
Save/Recall
InstrumentSettings
Internal
10 locations
External
90 locations
Measurement Resultsand Screenshots
External
1000 locations
General
Remote Interface
USB (Virtual COM), GPIB, LAN
Display
4.3” 480 × 272 color LCD display
AC Input
104 V - 126 V, 50/60 Hz
207 V - 253 V, 50/60 Hz
Power Consumption
20 VA max.
Operating Temperature
32 °F to 104 °F (0 °C to 40 °C)
Storage Temperature
14 °F to 158 °F (-10 °C to 70 °C)
Relative Humidity
up to 80%
Dimension (L × W × H)
10.1” x 4.4” x 15” (258 × 113 × 381 mm)
Weight
7.5 lbs (3.4 kg)
Three-Year Warranty
Standard Accessories
User manual, power cord, Kelvin clips (TL 889A), certificate of calibration & test report
Optional Accessories
TL89F1 test fixture (axial and radial)
(1) Accuracy is based on test signal level at 1 Vrms with slow measurement speed. At 0.5 Vrms test signal level, multiply Ae by 1.1.
The store will not work correctly when cookies are disabled.