Fluke has fused the power of a digital multimeter and a mA loop calibrator to produce their 787B ProcessMeter. The Fluke 787B allows users to multiply their troubleshooting abilities with a single compact device. Users benefit from the capabilities of the Fluke 87 DMM, with addition of the capacity for measuring, sourcing and simulating mA with the utmost precision and accuracy.
Fluke Connect® with ShareLive™ video call is the most comprehensive software and wireless test tool family that keeps you in contact with your entire team without leaving the field. The Fluke Connect family offers the largest system of connected test tools in the world. The software is compatible with the HTC One and One M8 running Android 4.4.x or higher, LG G3 and Nexus 5 running Android 4.4.x or higher, Samsung Galaxy S4 running Android 4.3.x or higher, Samsung Galaxy S5 running Android 4.4.x or higher. It also works with the iPhone models 4S and higher running iOS 8.0 or higher, iPad Air and iPad Mini (2nd generation) in an iPhone frame on iPad and iPod Touch (5th generation) and comes with over 30 different Fluke products. Please see our Fluke Connect category for the complete collection of Fluke Connect Products. Take me to Fluke Connect (Click Here).
Specifications
Measurement function
Range and resolution
Best accuracy (% of reading + LSD)
V dc
400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V
0.1% + 1
V ac (true-rms)
400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V
0.7% + 2
mA dc
30.000 mA
.05% + 2
A dc
1.000 A (0.440 A continuous)
0.2% + 2
A ac
1.000 A (0.440 A continuous)
1% + 2
Resistance
400.0 Ohms, 4.000 k, 40.00 k, 400.0 k, 4.0 M, 40 M
0.2% + 1
Frequency (0.5 Hz to 20 kHz)
199.99 Hz, 1999.9 Hz, 19.999 kHz
.005% + 1
Diode test
2.000 V (shows diode voltage drop)
2% + 1
Continuity
Beeps for resistance < approx. 100 ohms
Output function
Range and resolution
Drive capability
Accuracy (% of span)
DC current output (Internal battery operation)
0.000 to 20.000 mA or 4.000 to 20.000 mA, (selectable at power-up) Over-range to 24.000 mA
24 V compliance or, 1,200 ohms, @ 20 mA
0.05%
DC current simulate (Ext. 15 V to 48 V loop supply)
0.000 to 20.000 mA or 4.000 to 20.000 mA, (selectable at power-up) Over-range to 24.000 mA
1000 ohms, @ 20 mA
0.05%
Current adjustment modes
Manual: Coarse, Fine, 25% and 100% step
Automatic: Slow Ramp, Fast Ramp, 25% step
Temperature range of 18 °C to 28 °C, for one year after calibration
General Specifications
Maximum voltage applied between any jack and earth ground
1000 V RMS
Storage temperature
-40 °C to 60 °C
Operating temperature
-20 °C to 55 °C
Temperature coefficient
0.05 x (specified accuracy) per °C (for temperatures < 18 °C or > 28 °C)
Relative humidity
95% up to 30 °C; 75% up to 40 °C; 45% up to 50 °C; 35% up to 55 °C
Vibration
Random, 2 g, 5-500 Hz
Shock
1 meter drop test
Safety
IEC61010-1, Pollution Degree 2/IEC61010-2-033, CAT IV 600 V/CAT III 1000 V
The store will not work correctly when cookies are disabled.
We use cookies to make your experience better.To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies.Learn more.