Fluke’s T5-600/62 MAX+/1AC II IR Thermometer, Electrical Tester and Voltage Detector Kit combines the efficiency of 3 separate instruments into one single purchase.
The Fluke 62 MAX+ delivers precision with a 12:1 distance to spot ratio while the Fluke T5 measures volts AC and volts DC with the utmost of accuracy.
Specifications
Fluke T5-600 Voltage, Continuity and Current Tester
Specifications
Jaw opening
12.9 mm (0.5 in)
Max wire size
1/0 THHN cable
Current range AC rms
0 to 100.0 A
Accuracy AC current (50/60 Hz)
3% ± 3 counts
AC Response
Averaging
Voltage range AC
0 to 600 V
Accuracy AC voltage
1.5% ± 2 counts
Voltage range DC
0 to 600 V
Accuracy DC voltage
1% ± 1 count
Resistance range
0 to 1000 Ω
Continuity beeper threshold
On at < 25 Ω, off at > 400 Ω
Volts indicator LED threshold
Guaranteed on by 30 V AC
Environmental Specifications
Operating temperature
-10°C to 50°C
Storage temperature
-30°C to 60°C
Humidity (without condensation)
0% to 95% (5°C to 30°C); 0% to 75% (30°C to 40°C); 0% to 45% (40°C to 50°C)
Dust/water resistance
Yes
Operating altitude
2000 meters max
Temperature coefficient
0.1 x (specified accuracy)/°C (< 18°C or > 28°C)
Safety Specifications
Overvoltage category
CAT III 600 V AC/DC (EN61010-1)
Agency approvals
UL, CSA, and VDE
Maximum voltage
Between any terminal and earth ground
Mechanical and General Specifications
Size
30.5 x 51 x 203 mm
Weight
300 g
Warranty
Two-years
Battery life
200 hour zinc chloride, 400 hour alkaline
Battery type
2 x AA
Low battery indicator
Yes
Current sensor opening
12.9 mm
Calibration cycle
1 year
Test leads
Type
Heavy duty, flexible leads rated for 1000 V use. Field replaceable leads terminate in male shrouded banana plugs
Probes
One red, one black. Detachable Slim-Reach™ probe tips
Styles
TP1 Slim Reach™ test brobes
Safety Specifications
Safety
CAT IV 600 V, CAT III, 1000 V
Maximum voltage
1000 V AC rms from earth to ground, in compliance with EN61010
Fluke 62 MAX+ Infrared Thermometer
Specifications
Temperature range
-30°C to 650°C (-22°F to 1202°F)
Accuracy
±1.0°C or ±1.0% of reading, whichever is greater -10°C to 0°C: ±2.0 -30°C to -10°C: ±3.0
Response time (95%)
< 300 ms (95% of reading)
Spectral response
8 to 14 microns
Emissivity
0.10 to 1.00
Optical resolution
12:1 (calculated at 90% energy)
Display resolution
0.1°C (0.2°F)
Repeatability of readings
±0.5% of reading or < ±0.5°C (1°F), whichever is greater
Power
AA battery
Battery life
8 hours with laser and backlight on
Physical Specifications
Weight
255 g (8.99 oz)
Size
175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in)
Operating temperature
0°C to 50°C (32°F to 122°F)
Storage temperature
-20°C to 60°C (-4°F to 140°F), (without battery)
Operating humidity
10% to 90% RH non-condensing at 30°C (86°F)
Operating altitude
2000 meters above mean sea level
Storage altitude
12,000 meters above mean sea level
IP rating
IP 54 per IEC 60529
Drop test
3 meters
Vibration and shock
IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms
EMC
EN 61326-1:2006 EN 61326-2:2006
Standards and agency approval
Compliance
EN/IEC 61010-1: 2001
Laser safety
FDA and EN 60825-1 Class II
The store will not work correctly when cookies are disabled.