The GPT-9602 hipot voltage breakdown tester is capable of performing AC voltage testing up to 5000 volts and and DC withstandi tests to 6000 volts. It has never been easirer to meet safety standards to IEC, EN, UL, ETL, CSA, GB, JIS and others. The GPT-9601, GPT-9602, GPT-9603, and GPT-9612 are all equipped with the high-efficiency PWM amplifier.
Specifications
AC WITHSTANDING (All Models)
Output-Voltage Range
0.10kV~ 5.00kV ac
Output-Voltage Resolution
10V
Output-Voltage Accuracy
± (1.5% of setting + 2 counts) with no load
Maximum Rated Load
100 VA (5kV/20mA)
Maximum Rated Current
20mA (0.5kV < V ≦ 5kV)
5mA (0.1kV ≦ V≦ 0.5kV)
Output-Voltage Waveform
Sine wave
Output-Voltage Frequency
50 Hz / 60 Hz selectable
Voltage regulation
± (1.5% + 2 counts) [full load → no load]
Voltmeter Accuracy
± (1.5% of reading + 2 counts)
Current Measurement Range
0.01mA~20.0mA
Current Best Resolution
0.01mA / 0.1mA
Current Measurement Accuracy
±(2.0% of reading + 5 counts) when HISET < 1.00mA
±(2.0% of reading + 3 counts) when HISET ≧ 1.00mA
Current Judgment Accuracy
±(3.0% of setting + 5 counts) when HISET < 1.00mA
±(3.0% of setting + 3 counts) when HISET ≧ 1.00mA
Window Comparator Method
Yes
ARC Detect
Yes
RAMP (Ramp-Up Time)
0.1s fixed
TIMER (Test Time)
OFF, 1s~180s
GND
ON
DC WITHSTANDING (GPT-9602 & GPT-9603)
Output-Voltage Range
0.10kV~ 6.00kV dc
Output-Voltage Resolution
10V
Output-Voltage Accuracy
± (1.5% of setting + 2 counts) with no load
Maximum Rated Load
25W (5kV/5mA)
Maximum Rated Current
6mA (0.5kV < V ≦ 6kV)
2mA (0.1kV ≦ V≦ 0.5kV)
Voltage regulation
± (1.5% + 2 counts) [full load → no load]
Voltmeter Accuracy
± (1.5% of reading + 2 counts)
Current Measurement Range
0.01mA~6.00mA
Current Best Resolution
0.01mA
Current Measurement Accuracy
±(2.0% of reading + 5 counts) when HISET < 1.00mA
±(2.0% of reading + 3 counts) when HISET ≧ 1.00mA
Current Judgment Accuracy
±(3.0% of setting + 5 counts) when HISET < 1.00mA
±(3.0% of setting + 3 counts) when HISET ≧ 1.00mA
Window Comparator Method
Yes
ARC Detect
Yes
RAMP (Ramp-Up Time)
0.1s fixed
TIMER (Test Time)
OFF, 1s~180s
GND
ON
INSULATION RESISITANCE (GPT-9603 & GPT-9612)
Output-Voltage
50V, 100V, 250V, 500V, 1000V dc
Output-Voltage Accuracy
± (3.0% of setting + 1 count) [no load]
Resistance Measurement Range
1MW~ 2000MW
Test voltage
Measurable Range
Accuracy
50V/100V/250V
1~ 50MW
51~ 2000MW
±(5% of reading + 2MW)
±(10% of reading + 2MW)
500V/1000V
1~ 500MW
501~ 2000MW
±(5% of reading + 2MW)
±(10% of reading + 2MW)
Window Comparator Method
Yes
Output Impedance
600kW
RAMP (Ramp-Up Time)
0.1s fixed
TIMER (Test Time)
OFF, 1s~180s
GND
OFF (fixed)
TEST MODE*
SINGLE
ACW, DCW, IR
AUTO
AC-IR, IR-AC, DC-IR, IR-DC
INTERFACE
Remote Terminal (Front)
Standard
SIGNAL IO
Standard
General
DISPLY
240 x 48 Ice Blue dot matrix LCD
POWER SOURCE
AC 100V-120V/220V-240V ±10%, 50/60Hz
POWER COMSUMPTION
400VA max.
DIMENSIONS & WEIGHT
330(W) x 148(H) x 385(D) mm
approx.9kg(Max)
* The available “Test Mode” depends on selected model