The PEL-3000 series, a single-channel, programmable D.C. electronic load with 0.01mA current resolution and 16A/μs current Slew Rate, is very ideal for testing server power supply and SPS (Switching Power Supply) for commercial and industrial computers. For a heavy-duty device like cloud ecosystem running 24-hour nonstop operations, a stable and high-power power supply, ranging from 350W to 1500W, is required to maintain the normal operation of server, Hub, and the equipment of data storage and internet communications. Owing to the increasing demand of data transmission and large scale data storage of telecommunications systems, the infrastructure of internet communications is in the pace of rapid expansion. This has greatly boosted the market demand of telecommunications equipment powered by power supply of 2000W and above. The flexible power combination of PEL-3000 meets the test requirements of present high-power power supply.
Three Operating Functions
Specifications
Model
PEL-3021
PEL-3041
PEL-3111
PEL-3211
Voltage
1.5V~150V
1.5V~150V
1.5V~150V
1.5V~150V
Current
35A
70A
210A
420A
Power
175W
350W
1050W
2100W
Constant Current Mode
Operating Range
0~35A
0~3.5A
0~0.35A
0~70A
0~7A
0~0.7A
0~210A
0~21A
0~2.1A
420A
Accuracy of Setting
H,M,L
±(0.2 % of set + 0.1 % of f.s*1) + Vin*2/500 kΩ
±(1.2% of set +1.1% of f.s)
Accuracy of Setting(Parallel)
H,M,L
±(1.2 % of set + 1.1 % of f.s*3)
Resolution
1mA
0.1mA
0.01mA
2mA
0.2mA
0.02mA
10mA
1mA
0.1mA
N/A
Constant Resistance Mode
Operating Range
H
23.33365S~400uS (42.857mΩ~2.5kΩ)
46.6672S~800uS (21.428mΩ~1.25KΩ)
140.0016S~2.4mS (7.1427mΩ~416.6667Ω)
28.0002s~484.8us (35.7135mΩ~2.08334Ω)
M
2.33336S~40uS (428.566mΩ~25kΩ)
4.6667S~80uS (214.28mΩ~12.5kΩ)
14.0001S~242.4uS (71.427mΩ~4.16667Ω)
L
0.233336S~4uS (4.28566Ω~250kΩ)
0.46667S~8uS (2.1428Ω~125kΩ)
1.40001S~24.24uS (714.27mΩ~41.6667kΩ)
Accuracy of Setting
H,M,L
±(0.5 % of set*4 + 0.5 % of f.s*1) + Vin*3/500kΩ
±(1.2% of set +1.1% of f.s)
Resolution
400uS
40uS
4uS
800uS
80uS
8uS
2.4mS
240uS
24uS
N/A
Constant Voltage Mode
Operating Range
H
1.5V~150V
1.5V~150V
1.5V~150V
1.5V~150V
L
1.5V~15V
1.5V~15V
1.5V~15V
1.5V~15V
Accuracy of Setting
H,L
±(0.1 % of set + 0.1 % of f.s.)
±(0.1 % of set + 0.1 % of f.s.)
±(0.1 % of set + 0.1 % of f.s.)
N/A
Resolution
H,L
10mV / 1mV
10mV / 1mV
10mV / 1mV
N/A
Constant Power Mode
Operating Range
H
17.5W~175W
35W~350W
105W~1050W
210W~2100W
M
1.75W~17.5W
3.5W~35W
10.5W~105W
21W~210W
L
0.175W~1.75W
0.35W~3.5W
1.05W~10.5W
2.1W~21W
Accuracy of Setting
H,M,L
±(0.6 % of set*5 + 1.4 % of f.s*6)
N/A
Resolution
10mW
1mW
0.1mW
10mW
1mW
0.1mW
100mW
10mW
1mW
N/A
PARALLEL Mode
Capacity
875W
1750W
5250W
PEL-3111 with 4 booster units: Max 9.45kW
Slew Rate
Setting Range (CC mode)
H
2.5mA/us~2.5A/us
5mA/us~5A/us
16mA/us~16A/us
16mA/us~16A/us
M
250uA/us~250mA/us
500uA/us~500mA/us
1.6mA/us~1.6A/us
1.6mA/us~1.6A/us
L
25uA/us~25mA/us
50uA/us~50mA/us
160uA/us~160mA/us
N/A
Resolution
0.1uA ~ 1mA
0.2uA ~ 2mA
0.6uA ~ 6mA
N/A
Setting Range (CR mode)
H
250uA/us~250mA/us
500uA/us~500mA/us
1.6mA/us~1.6A/us
1.6mA/us~1.6A/us
M
25uA/us~25mA/us
50uA/us~50mA/us
160uA/us~160mA/us
160uA/us~160mA/us
L
2.5uA/us~2.5mA/us
5uA/us~5mA/us
16uA/us~16mA/us
N/A
Resolution
0.1uA ~ 1mA
0.2uA ~ 2mA
0.6uA ~ 6mA
N/A
Accuracy of Setting
H,M,L
±(10 % of set*7+ 5us)
N/A
METER
Voltmeter
Accuracy
±(0.1 % of rdg + 0.1 % of f.s.)
N/A
Ammeter
Accuracy
±(0.2 % of rdg + 0.3 % of f.s.)
N/A
Ammeter (Parallel Operation)
Accuracy
±(1.2 % of rdg + 1.1 % of f.s.)
N/A
DYNAMIC MODE
Operation mode
CC / CR
T1 & T2
0.025ms ~ 10ms / Res : 1us ; 1ms ~ 30s / Res : 1ms
Accuracy
1us / 1ms ±100ppm
Slew Rate (CC Mode)
H
2.5mA/us~2.5A/us
5mA/us~5A/us
16mA/us~16A/us
16mA/us~16A/us
M
250uA/us~250mA/us
500uA/us~500mA/us
1.6mA/us~1.6A/us
1.6mA/us~1.6A/us
L
25uA/us~25mA/us
50uA/us~50mA/us
160uA/us~160mA/us
N/A
Slew Rate (CR Mode)
H
N/A
M
L
Current Accuracy
±0.4%F.S
±0.4%F.S
±0.4%F.S
±(1.2% of set +1.1% of f.s)
Protection Function
Overvoltage (OVP)
Adjustable ; Turns off the load at 110% of the rated voltage
N/A
Overcurrent (OCP)
0.03A ~ 38.5A (Adjustable)
0.06A ~ 77A (Adjustable)
0.2A ~ 231A (Adjustable)
Overpower (OPP)
0.1W ~ 192.5W (Adjustable)
0.3W ~ 385W (Adjustable)
1W ~ 1155W (Adjustable)
Overheat (OHP)
Turns off the load when the heat sink temperature reaches 95 °C
Undervoltage (UVP)
Adjustable : Turns off the load when detected. Can be set in the range of 0 V to 150 V or Off.
Reverse connection (REV)
By diode. Turns off the load when an alarm occurs.
General Specifications
Power Source
AC100V ~ 230V±10% ; 50Hz / 60Hz ± 2Hz
Interface
USB/RS232C/Analog Control (Standard) ; GPIB(Option)
Weight
Approx. 6kg
7kg
17kg
23kg
DIMENSIONS & WEIGHT
214.5(W)x124(H)x400(D)mm.
214.5(W)x124(H)x400(D)mm
429.5(W)x128(H)x400(D)mm
427.7(W)x128(H)x592.5(D)mm
*1 Full scale of H rangerated current. *2 Vin: input terminal voltage of electric load. *3 M range applies to the full scale of H range *4 Set = Vin / Rset *5 It is not applied for the conditon of the parallel operation *6 M range applies to the full scale of H range *7 Time to reach from 10% ~ 90% when the current is varied from 2% ~ 100% (20% ~ 100% in M range) of the rated current.