Practical Instrument Electronics’ PIECAL 235 Process Voltage Calibrator allows for the verification, calibration and measurement of voltage, millivolt and pH signal instruments. The 235 is equipped to measure from -500.00 to +999.00 mV, 0.000 to 5.100 V, -25.0 to 125.0 % of 1 to 5 V; 0 to 20.000 V and 0.00 to 60.00 V DC. Ideal for checking I/V converters, loop power supplies, 1 to 5 volt signals and other voltages, the PIECAL 235 is a process voltage calibrator of an overall comprehensive value.
Specifications
General
Operating Temperature
Range
-20 to 60 °C (-5 to 140 °F)
Storage Temperature Range
-30 to 60 °C (-22 to 140 °F)
Temperature effect
≤ ± 0.005 %/°C of Full Scale
Relative Humidity Range
10 % ≤RH ≤90 % (0 to 35 °C), Non-condensing
10 % ≤RH≤ 70 % (35 to 60 °C), Non-condensing
Common Mode Rejection
50/60 Hz, 100 dB
Normal Mode Rejection
50/60 Hz, 50 dB
Noise
≤ ± ½ Least Significant Digit from 0.1 to 10 Hz
Size
5.63 x 3.00 x 1.60 in, 143 x 76 x 41mm (L x W x H)
Weight
12.1 ounces, 0.34 kg (including boot & batteries)
Batteries
Four “AA” Alkaline 1.5V (LR6)
Battery Life
≥ 50 hours
Low Battery
Low battery indication with nominal 1 hour of
operation left
Protection against misconnection
Over-voltage protection to 60 vrms (rated for 30 seconds). Red LED and audible alarm indicates OVERLOAD for out of range conditions.
Display
High contrast graphic liquid crystal display with
0.35” (9 mm) high digits on main & 0.2” (5 mm) on
mA display. LED backlighting for use in low lit areas.
Voltage Source
Ranges and Resolution -500.00 to 999.00 mV 1.000 to 5.000 V 0.000 to 20.000 V -25.0 to 125.0% of 1 to 5 V
Accuracy ≤ ± (0.02 % of Reading + 0.01% of Full Scale) ≤ ± (0.02 % of Reading + 0.002 V) ≤ ± (0.02 % of Reading + 0.01% of Full Scale) ≤ ± 0.1%
Source Current
≥ 20 mA
Sink Current
> 16 mA
Output Impedance
≤ 0.3 Ohm at ≤ 20 mA load
Short Circuit Duration
Infinite
Voltage Read
Range and Resolution -500.00 to 999.00 mV 1.000 to 5.000 V 0.000 to 20.000 V -25.0 to 125.0% of 1 to 5 V 0.00 to 60.00 V
Accuracy ≤ ± (0.02 % of Reading + 0.01% of Full Scale) ≤ ± (0.02 % of Reading + 0.002 V) ≤ ± (0.02 % of Reading + 0.01% of Full Scale) ≤ ± 0.1% ≤ ± (0.02 % of Reading + 0.02 V)
Input resistance
≥ 1 MΩ
pH Source
Accuracy in mV Accuracy in pH
≤ ± (0.02 % of Reading in mV + 0.1 mV) ≤ ± 0.003 pH @ 25°C