The GPT-9800 Series look to meet a variety of safety standards such as IEC, EN, UL, CSA, GB, JIS and other safety-related requirements for the safety tests of electronic products and components. The GPT-9802 is capable of performing both AC and DC withstanding tests, whereas the GPT-9801 is able to perform AC withstanding test. The series of safety tester is built upon a high-efficiency PWM amplifier platform with AC 200VA maximum output capacity to impede the influence from the voltage fluctuation of the input AC source. This ensures a stable voltage supply for all the tests of the GPT-9800 Series.
Specifications
AC WITHSTANDING
Output-Voltage Range
0.100kV~ 5.000kV ac
Output-Voltage Resolution
2V/step
Output-Voltage Accuracy
± (1% of setting +5V) [no load]
Maximum Rated Load
200 VA (5kV/40mA)
Maximum Rated Current
40mA (0.5kV < V ≦ 5kV)10mA (0.1kV ≦ V≦ 0.5kV)
Output-Voltage Waveform
Sine wave
Output-Voltage Frequency
50 Hz / 60 Hz selectable
Voltage regulation
± (1% of reading +5V) [full load → no load]
Voltmeter Accuracy
± (1% of reading+ 5V)
Current Measurement Range
0.001mA~040.0mA
Current Best Resolution
0.001mA / 0.01mA / 0.1mA
AC Current Measurement Accuracy
±(1.5% of reading +30 counts) when HISET < 1.00mA±(1.5% of reading +3 counts) when HISET ≧ 1.00mA
Window Comparator Method
Yes
ARC Detect
Yes
RAMP (Ramp-Up Time)
0.1~999.9s
TIMER (Test Time)*
OFF, 0.5s~999.9s
GND
ON/OFF
DC WITHSTANDING
Output-Voltage Range
0.100kV~ 6.000kV dc
Output-Voltage Resolution
2V/step
Output-Voltage Accuracy
± (1% of setting +5V) [no load]
Maximum Rated Load
50W (5kV/10mA)
Maximum Rated Current
10mA (0.5kV < V ≦ 6kV)2mA (0.1kV ≦ V≦ 0.5kV)
Voltage regulation
± (1% of reading +5V) [full load → no load]
Voltmeter Accuracy
± (1% of reading+ 5V)
Current Measurement Range
0.001mA~010.0mA
Current Best Resolution
0.001mA / 0.01mA / 0.1mA
DC Current Measurement Accuracy
±(1.5% of reading +30 counts) when HISET < 1.00mA±(1.5% of reading +3 counts) when HISET ≧ 1.00mA
Window Comparator Method
Yes
ARC Detect
Yes
RAMP (Ramp-Up Time)
0.1~999.9s
TIMER (Test Time)*
OFF, 0.5s~999.9s
GND
ON/OFF
INSULATION RESISITANCE
Output-Voltage
50V~1000V dc
Output-Voltage Resolution
50V/step
Output-Voltage Accuracy
± (1% of setting +5V) [no load]
Resistance Measurement Range
1MW~ 9500MW
Test voltage
Measurable Range
Accuracy
50V≦V≦450V
1MW~ 50MW51MW~ 2000MW
±(5% of reading +1 count)±(10% of reading +1 counts)
500V≦V≦1000V
1MW~ 500MW501MW~ 9500MW
±(5% of reading +1 count)±(10% of reading +1 count)
Window Comparator Method
Yes
Output Impedance
600kW
RAMP (Ramp-Up Time)
0.1~999.9s
TIMER (Test Time)
1s~999.9s
GND
OFF (fixed)
GROUND BOND
Output-Current Range
03.00A~30.00A ac
Output-Current Resolution
0.01A
Output-Current Accuracy
3A≦I≦8A :± (1% of setting +0.2A)8A<I≦30A :± (1% of setting +0.05A)
Test-Voltage
6Vac max. (open circuit)
Test-Voltage Frequency
50 Hz / 60 Hz selectable
Resistance Measurement Range
10mW~650.0mW
Resistance Measurement Resolution
0.1mW
Resistance Measurement Accuracy
± (1% of reading +2mW)
Window Comparator Method
Yes
TIMER (Test Time)
0.5s~999.9s
GND
OFF (fixed)
Test Method
Four Terminal
MEMORY
Single Step Memory
MANU : 100 blocks
Automatic Testing Memory
AUTO : 100 blocks, menu per auto : 16
INTERFACE
RS232
Standard
USB (Device)
Standard
GPIB
Option
Remote Terminal (Front)
Standard
SIGNAL IO
Standard
General
DISPLY
240 x 64 dot matrix LED back light LCD
POWER SOURCE
AC100V/120V/220V/230V ±10%, 50/60Hz
POWER CONSUMPTION
500VA max.
DIMENSIONS & WEIGHT
330(W) x 148(H) x 452(D) mm (Max.),approx.19kg(Max)
* The “TIMER OFF” can only be performed when the tester is in the special MANU mode