Cover a pressure range from 1 PSI to 10,000 PSI with Setra’s 209 pressure sensor. The 209 was conceived as a solution for industrial and OEM customers searching for a top performing, reliable and versatile pressure sensor. Offering a superior accuracy of ±0.25% FS, Setra’s 209 boasts a true low range sensor. The sensor provides high performance without the need of further amplification necessary to satisfy range requirements as low as 1 PSI.
The 209 offers a wide range of adaptability, making it ideal for numerous applications. Its patented optional overpressure stop guards the sensor against unpredicted spikes or in high pulsation applications. Likewise, with the many pressure and electrical fittings offered, the 209 can fulfill an expanse of installation configurations.
Specifications
PerformanceData
EnvironmentalData
Accuracy RSS1 (at constant temp)
±0.25% FS
Operating3 Temperature °F (°C)
-40 to + 185 (-40 to +85)
Non-Linearity, BFSL
±0.22% FS
Storage Temperature °F (°C)
-40 to + 185 (-40 to +85)
Hysteresis
0.10% FS
Shock3
200g operating
Non-Repeatability
0.05% FS
Acceleration
10 g Maximum5
ThermalEffects
Shock3
200g Operating
Compensated Range °F (°C)
-4 to +176 (-20 to +80)
Vibration4
20g
Zero Shift %FS/100°F (%FS/50°C)
±2.0 (±1.8)
Environmental Protection
Weather Resistant
Span Shift %FS/100°F (%FS/50°C)
±1.5 (±1.3)
Electrical Data(Voltage)
Warm-up Shift
0.1% FS Total
Circuit
3-Wire (COM, OUT, EXC)
Response Time
5 milliseconds
Excitation
9 to 30 VDC
Long Term Stability
0.5% FS/1 YR
Output6
0.5 to 5.5 VDC7
PressureMedia
Output Impedance
10 ohms
Liquids and gases compatible with 17-4 PH Stainless Steel.2
Electrical Data(Current)
PhysicalDescription
Circuit
2-Wire
Case
Stainless Steel & Valox
Output8
4 to 20mA9
Wetted Material
17-4 PH Stainless Steel
External Load
0 to 800 ohms
Electrical Connection
2 ft. multiconductor cable
Minimum supply voltage (VDC)
9+ 0.02 x (Resistance of receiver plus line)
Pressure Fitting5
1/4” -18 NPT external,
17-4 PH Stainless Steel
Maximum supply voltage (VDC)
30+ 0.004 x (Resistance of receiver plus line).
Vent
Through cable
1 RSS of Non-Linearity, Hysteresis, and Non-Repeatability.
2 Note: Hydrogen not recommended for use with 17-4 PH Stainless Steel.
3 Mil-Std. 202, Method 213B, Cond. C
4 Mil-Std. 202, Method 204, Cond. C
5 See ordering information for other fittings available (minimum quantities apply).
6 Calibrated into a 50K ohm load, operable into a 5000 ohm load or greater.
7 Zero output factory set to within ±50mV. Span (Full Scale) output factory set to within ±50mV.
8 Calibrated at factory with a 24 VDC loop supply voltage and a 250 ohm load.
9 Zero output factory set to within ±0.16mA. Span (Full Scale) output factory set to within ±0.16mA.
Specifications subject to change without notice.
Weight (approx.)
2.3 ounces (65 grams)