Setra’s 206 is the solution to OEM customers in need of a top performing, reliable and versatile pressure sensor at an reasonable price. Covering a pressure range, as low as 25 PSI up to 10,000 PSI, the 206 provides a superior accuracy of ±0.13% FS.
Designed on the premise of precision and accuracy, the 206 is physically constructed for a range of demanding applications. Made with all stainless steel wetted materials, the pressure sensor is manufactured to satisfy NEMA4 and IP65 environmental ratings.
Setra’s 206 is equipped with numerous pressure and electrical connections making it adaptable to a range of installation configurations, while its zero and span potentiometers allow for calibration in the field.
Specifications
For Cable Length Longer than 25' Please Call
PerformanceData
PhysicalDescription
Accuracy RSS1
(at constant temperature)
±0.13% FS
Pressure Fittings
See Ordering Information in the Data Sheet
Non-Linearity, (BFSL)
25 PSIG range2
±0.1% FS
±0.2% FS
Vent
Through cable or terminal
Hysteresis
0.08% FS
Electrical Connection
2 ft. multiconductor cable
Non-Repeatability
0.02% FS
Case
Stainless Steel
Response Time
5 milliseconds
Zero/Span Adjustments
Top External Access
Long Term Stability
0.5% FS/1 YR
Weight (approx.)
6 oz
ThermalEffects
Electrical Data(Voltage)
Compensated Range
-4 to +176°F (-20 to +80ºC)
Excitation/Output
12 to 28 VDC
Reverse Excitation Protected
Zero Shift
±1% FS/100°F (±0.9% FS/50°C)
Power Consumption
<0.15 watts
(approx. 5mA @24VDC)
Span Shift
±1.5% FS/100°F (±1.4% FS/50°C)
Output8
0.1 to 5.1 VDC9
PressureMedia
Output Impedance
100 ohms
Gases or liquids compatible with 17-4 PH Stainless Steel.3
Circuit
3-Wire (Exc, Out, Com)
EnvironmentalData
Vibration11
200g Operating
Temperature
Electrical Data(Current)
Operating4
-40 to +185°F (-40 to +85ºC)
Circuit
2-Wire
Storage
-40 to +185°F (-40 to +85ºC)
Output10
4 to 20 mA11
Acceleration
10g Maximum5
External Load
0 to 800 ohms
Shock6
200g Operating
Min. Supply Voltage (VDC) = 9 +0.02 x (Resistance of receiver plus line)
Vibration7
20g 50-2000 Hz
1 RSS of Non-Linearity, Non-Repeatability and Hysteresis 2 25 PSIG range accuracy is ±0.22% of Full Scale output 3 Hydrogen not recommended for use with 17-4 PH stainless steel. 4 The high temperature limit of the cable is 200ºF (95ºC) 5 Shift in output reading <0.05 psi/g typical; pressure port axis only 6 Mil-Std. 202, Method 213B, Cond. C 7 Mil-Std. 202, Method 204, Cond. C 8 Calibrated into a 50K ohm load, operable into a 5000 ohm load or greater 9 Zero output factory set to w/in ±25mV. Span (FS) output factory set to w/in ±50mV. 10 Calibrated at factory with a 24VDC loop supply voltage and 250ohm load. 11 Zero output factory set to w/in ±0.08mA. Span (FS) output factory set to w/in ±0.16mA.
Max. Supply Voltage (VDC) = 30 + 0.004 x (Resistance of receiver plus line)