The Fluke 113 Utility Multimeter has the features needed to repair most electrical problems. This meter is simple to use and has significant improvements over Fluke's original 7-600, and other utility multimeters. With features such as Fluke's VCHEK™, added measurement functions, backlight, conformance to the latest safety standards, and a much larger display that's easier to view, this new meter is a must have for the utility users toolbox.
Specifications
Specifications
VCHEK1 2 3
Range
6.000 V / 60.00 V / 600.0 V
Resolution
0.001 V / 0.01 V/ 0.1 V
Accuracy
DC, 45 to 500 Hz: 2.0% + 3 500 Hz to 1 kHz: 4.0% + 3
Diode test4
Range
2.000 V
Resolution
0.001 V
Accuracy
2.0% + 3
Continuity4
Accuracy
Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer
1. All VChek voltage ranges are specified from 60 counts to 100% of range. Because inputs below 60 counts are not specified, it is possible and normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together. 2. Crest factor of ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full scale. 3. Minimum measureable input in VCHEK autorange is 3 VDC. For measurements below 3 VDC, push Range button twice to get to 6 VDC manual range. 4. After measuring voltage, a wait time of 1 minute is required to maintain accuracy of ohms, capacitance, diode test, and continuity.
Specifications
Maximum voltage between any terminal and earth ground
600 V
Display
3 3/4-digits, 6000 counts, updates 4/sec
Operating temperature
-10°C to 50°C (14°F to 122°F)
Storage temperature
-40°C to 60°C (-22°F to 140°F)
Temperature coefficient
0.1 x (specified accuracy) / °C (< 18°C or > 28°C)
Operating altitude
2,000 m
Storage altitude
10,000 m
Relative humidity
95% to 30°C 75% to 40°C 45% to 50°C
Battery type
9 Volt Alkaline, ANSI 1604A / IEC 6F22
Battery life
Alkaline: 300 hours typical, without backlight
Shock
1 Meter drop per IEC 61010–1–2001
Vibration
Per MIL-PRF-28800 for Class 2 instrument
Size (H x W x L)
167.1 x 85.1 x 46.0 mm (6.58 x 3.35 x 1.81 in)
Weight
13.0 oz (404 g)
Safety
Complies with ANSI / ISA 82.02.01 (61010–1) 2004, CAN / CSA-C22.2 No 61010-1-04, UL 61010–1 (2004) and IEC / EN 61010–1 2nd Edition for measurement Category IV, 600 V, Pollution Degree 2, EMC EN61326–1
EMI regulations
Complies with FCC Part 15, Class B
Specifications
VCHEK
Input impedance (nominal)
~3 kΩ < 300 pF
VCHEK
Common mode rejection ratio (1 kΩ unbalanced)
> 60 dB at DC, 50 or 60 Hz
Ω
Open circuit test voltage
< 2.7 VDC
Full scale voltage
< 0.7 VDC
Diode test
Open circuit test voltage
2.7 VDC
Full scale voltage
2.000 VDC
Ω
Short circuit current
< 350 μA
Diode test
Short circuit current
< 1.0 mA
The store will not work correctly when cookies are disabled.