Incorporating traditional variable area precision glass technology, these rugged PTFE flow meters offer accurate and economical solutions to medium flow range measurements. V meters are designed with unique rotatable scales of dual air-water direct reading graduations showing SCFM and SLPM (air), as well as GPM and LPM (water) markings.
Specifications
SCALES
Rotatable, direct reading air, (SCFM-L/min) and water (GPM-LPM).
ACCURACY
±5% of full scale.
MAXIMUM TEMPERATURE
250 °F (121 °C).
MAXIMUM PRESSURE
150 psig (@ 200 °F).
CONNECTIONS
3/8" NPT female in line or horizontal rear.
**MATERIALS OF CONSTRUCTION
TUBE SHIELDS
Polycarbonate
FLOW TUBES
Heavy walled precision formed borosilicate glass.
FLOATS
Type 316 stainless steel.
WETTED PARTS
Brass or type 316 stainless steel.
SEALS OPTIONAL:
Viton® standard. Buna-N® , PTFE /Kalrez® and EPR.
**The selection of materials of construction, is the responsibility of the customer. The company accepts no liability.