Flowline Thermo-Flo XT10 is offered in liquid and gas sensor types, the general purpose flow switch provides reliable low or no-flow detection of relatively clean, non-coating media with one 1A relay output. Liquid examples water and acetic acid. Available in Polypropylene-Ryton®, the short flow sensor is used in pipe or ducting from 1/2" to 1 1/2", and the long flow sensor is used in 2" and up. The flow switch set point may be adjusted from 0.04 to 3 fps in liquids, or 1 to 90 fps in gases as a low-flow alarm. The flow sensor is best applied in applications with relatively constant temperature.
If you want the FT10/GT10 with the PVDF sensor material Click Here.
Specifications
Set point range:
FT10: 0.04 to 3 fps (0.012 to 0.91 mps) GT10: 1 to 90 fps (0.3 to 27 mps)
Factory set point:
FT10: 2 fps (.06 mps) GT10: 10 fps (27 mps)
Repeatability:
± 0.5% of set point @ fixed temperature
Response time:
1-10 seconds
Set point adjust.:
Potentiometer
Viscosity range:
FT10: 1-200 centipoise
LED indication:
Flow status
Supply voltage:
12-36 VDC
Consumption:
70 mA maximum
Contact type:
(1) SPST relay
Contact rating:
60 VA, 1A maximum
Contact output:
Selectable NO / NC
Process temp.:
F: 32° to 140° C: 0° to 60°
Ambient temp.:
F: -40° to 140° C: -40° to 60°
Pressure:
150 psi (10 bar) @ 25º C, derated @ 1.667 psi (0.113 bar) per ºC above 25º C
Sensor rating:
NEMA 4X (IP65)
Wetted material:
-1XX5: PP-Ryton® -5XX5: PVDF
Cable jack. mat.:
-1XX5: PP -5XX5: PFA
Cable type:
4-conductor, shielded #22 AWG
Cable length:
10' (3m)
Process mount:
3/4" NPT (3/4" G)
Mount. gasket:
Viton®
Classification:
General purpose
Compliance:
CE
Dimensions
The store will not work correctly when cookies are disabled.