The Extech PRT200 checks phase sequence and phase status and tests up to 1000VAC with LED and audible indication.
Specifications
Measurement Principle Static induction Input Voltage 75 to 1000VAC Frequency Range 45 to 65Hz Max conductor diameter 33mm (1.3”) Probe length 86cm (34”) Auto-Off 5 min. without sequence detection Low Battery Warning Power LED flashes Batteries 4 x 1.5V AA Current consumption 15mA Operating Temperature & Humidity -10°C to 50°C (14°F to 122°F) Max. 80% R.H. Storage temperature & Humidity -20°C to 60° (-4°F to 140°F) Max. 80% R.H. Safety This meter is intended for origin of installation use and protected, against the users, by double insulation per EN61010-1 to Category IV 600V and Category III 1000V; Pollution Degree 2. Approvals CE