Providing high level of functionality and monitoring capability, the Aeroqual Series can be used portably or fixed in position. The monitor is compatible with the full range of Aeroqual gas sensors. The remote sensor head adaptor kit is designed to allow the sensor head to be located up to 46 ft away from the main unit.
*Order Gas Sensor Head's Separately
Specifications
Measurments Units
ppm or mg/m3
Sensor Head
Removable and Replaceable
Reading Functions
Minimum / Maximum / Average / 15-min
Functions
On-board alarm Alarm status displayed Alarm mute function Low battery indication Sensor condition status Stand-by mode Remote sensor capability Data logging and transfer data to PC On-board real-time clock
Alarm output
Transistor output, 150 mA max Low alarm, High alarm & Control
Analog output
0 to 5 V
Digital output
USB
On-board Data Logging
8188 data points
Power Supply
Li-Ion Battery (lasts up to 8 hrs) or AC Adapter
Enclosure Rating
IP20 & NEMA 1 equivalent
Dimensions (with sensor head)
7.0 x 4.75 x 2.0 inches (195 x 122 x 54 mm)
Weight (with sensor & battery)
< 16 oz (460 g)
Approvals
Part 15 of FCC Rules EN 50082-1: 1997 EN 50081-1: 1992
Gas Sensor Head Specifications*Order Gas Sensor Head Separately
Sensor
Range (ppm)
Accuracy of Calibration
Min. Detection Limit (ppm)
Resolution (ppm)
Operational Range
Temperature
RH
Ammonia
0-100
<±10%
0.2
0.1
32-104°F
10-90%
Ammonia (leak)
0-1000
<±15%
2
1
32-104°F
10-90%
Carbon Monoxide
0-25
<±0.5 ppm 0-5 ppm; <±10% 5-25 ppm
0.05
0.01
32-104°F
10-90%
Carbon Monoxide
0-100
<±1 ppm 0-10 ppm; <±10% 10-100 ppm
0.2
0.1
32-104°F
10-90%
Carbon Monoxide
0-1000
<±10%
1
1
32-104°F
10-90%
Carbon Dioxide
0-2000
<±10 ppm +5%
10
1
32-104°F
10-90%
Carbon Dioxide
0-5000
<±20 ppm +5%
20
1
32-104°F
10-90%
Chlorine
0-10
<±10%
0.02
0.01
32-104°F
10-90%
Formaldehyde
0-10
<±0.05 ppm 0-0.5 ppm; <±10% 0.5-10 ppm
0.01
0.01
32-104°F
10-90%
Hydrogen
0-5000
<±10%
5
1
32-104°F
10-90%
Hydrogen Sulphide
0-10
<±0.05 ppm 0-0.5 ppm; <±10% 0.5-10 ppm
0.04
0.01
32-104°F
10-90%
Hydrogen Sulphide
0-100
<±0.5 ppm 0-5 ppm; <±10% 5-100 ppm
0.4
0.1
32-104°F
10-90%
Methane
0-10000
<±15%
10
1
32-104°F
10-90%
Nitrogen Dioxide
0-1
<±0.02 ppm 0-0.2 ppm; <±10% 0.2-1 ppm
0.005
0.001
32-104°F
10-90%
Ozone
0-0.15
<±0.005 ppm
0.001
0.001
32-104°F
10-90%
Ozone
0-0.5
<±0.008 ppm 0-0.1 ppm; <±10% 0.1-0.5 ppm
0.001
0.001
32-104°F
10-90%
Ozone
0-10
<±0.1 ppm 0-1 ppm; 15% 1-10 ppm
0.02
0.01
32-104°F
10-90%
Perchloroethylene
0-200
<±5 ppm 0-50 ppm; <±10% 50-200 ppm
1
1
32-104°F
10-90%
Sulphur Dioxide
0-10
<±0.05 ppm 0-0.5 ppm; <±10% 0.5-10 ppm
0.04
0.01
32-104°F
10-90%
Sulphur Dioxide
0-100
<±0.5 ppm 0-5 ppm; <±10% 5-100 ppm
0.4
0.1
32-104°F
10-90%
VOC (GSS sensor)
0-25
<±10%
0.1
0.1
32-104°F
10-90%
VOC (GSS sensor)
0-500
<±10%
1
1
32-104°F
10-90%
VOC (PID sensor)
0-20
<±10%
0.02
0.01
32-104°F
10-90%
VOC (PID sensor)
0-1000
<±10%
0.2
0.1
32-104°F
10-90%
Temperature
-20-100°C
<± 0.3°C
0.01°C
-40-248°F
0-105%
Humidity
0 to 100%
<± 2% RH
1% RH
-40-248°F
0-105%
Multi-Gas IAQ Sensor Heads
Sensor Head
Gases
Range (ppm)
Accuracy of Calibration
Minimum Detection Limit (ppm)
Resolution (ppm)
Operational Temperature Range
Operational RH Range
MS1
CO CO2
0-2000 0-100
<±10 ppm +5% <±10% 1-100 ppm
10 0.2
1 0.1
32-104°F
10-90%
MS2
CO CO2 VOC
0-2000 0-100 0-20
<±10 ppm +5% <±10% 1-100 ppm <±10%
10 0.2 0.02
1 0.1 0.01
32-104°F
10-90%