The MN185 is a high accuracy mini probe for measurements to 120AAC. This probe uses a special magnetic core to provide higher accuracy and lower phase shift. The MN185 provides an output signal of 1mAAC/AAC. The output termination are standard 4mm banana jacks.
Specifications
ELECTRICAL
Nominal Range
150A
Measurement Range
50mA to 150A
Transformation Ratio
1000:1
Output Signal
1mAAC/AAC (120mA @ 120A)
Accuracy (120A Range)
50mA to 100A
1% of Reading ± 0.01A (with noninductive load)
100 to 120A
1.5% of Reading ± 0.01A
Phase Shift (120A Range) 1 to 100A/ 50 to 60Hz
≤3.5°
Overload Frequency Range
170A continuous 30Hz to 10kHz
Load Impedance
5Ω max
Working/Common Mode Voltage
250VAC/30VAC
Output Termination
Jack
MECHANICAL
Jaw Opening
0.78" (20mm)
Maximum Conductor Size
0.47"Ø max (12mm)
Dimensions
1.26 x 4.53 x 0.87" (32 x 115 x 22mm)
Weight
5.6 oz (160g)
Polycarbonate Material
Handles 10% fiberglass charged polycarbonate UL94 VO
ENVIRONMENTAL
Operating Temperature
13° to 122°F (-25° to 50°C)
Storage Temperature
-40° to 176°F (-40° to 80°C)
Operating Relative Humidity
10 to 35°C 85% RH (without roll-off above 35°C)
SAFETY
Electrical
30V max common between output & ground; 3kV50/60Hz dielectric for 1mm
Note: Reference conditions: 23°C ±3K, 20 to 85%RH, 48 to 65Hz, external magnetic field <40A/m, no DC component, no external current carrying conductor, test sample centered, load impedance 1Ω.
The store will not work correctly when cookies are disabled.