We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
Offering all the benefits of their PD685, Precision Digital’s PD686 boasts FM and CSA approvals as Intrinsically Safe and Nonincendive.
Click here to see Precision Digital’s PD685 NEMA 4X Loop Powered Digital Meter.
Input: 4-20 mA @ 30 VDC maximum
Display: 1.0" (25.4 mm) LCD, 3½ digits; 1999
Accuracy: ±0.1% FS ±1 count
Approvals: FM Approved & CSA Certified as intrinsically safe with entity, for use in Class I, II, III, Division 1, Groups A, B, C, D, E, F, & G; T-code = T4; hazardous locations. Non-incendive for use in Class I, II, III, Division 2, Groups A, B, C, D, F, & G.
Entity Parameters: Vmax= 30 V, Imax = 175 mA, Ci= 0 µF, Li = 0 µH, Pi = 1.3 W
FM Approved: Intrinsically Safe, Class I Zone 0
Decimal Point: User selectable
Calibration: Two-step; non-interacting zero and span
Calibration Range: 4 mA input: -1000 to +1000;
20 mA input: between 20 and 2000 counts > 4 mA display
Display Update Rate: 2.5/second
Maximum Input Current: 30 mA
Maximum Voltage Drop: 1 V @ 20 mA
Operating Temperature: PD686: -40 to 85°C
for Canadian installations -40 to 40°C.
Storage Temperature: -40 to 85°C
Relative Humidity: 0 to 90% non-condensing
Enclosure: Impact-resistant glass filled polycarbonate body, color: gray; impact-resistant clear polycarbonate cover; NEMA 4X, IP67
Connections: Removable screw terminals accept 12 to 26 AWG
Conduit Hole: One ½" conduit hole provided; refer to Ordering Information to specify conduit hole location; request models with rear conduit hole (-X) for panel mounting applications.
Weight: 12 oz (340 g)
Warranty: 2 years parts & labor