Precision Digital Loop Leader PD6606 Intrinsically Safe & Nonincendive Loop-Powered Digital Process Meter

SKU
PD6606
Manufacturer:
Precision Digital

Key Features:

  • 4-20 mA Input
  • Loop-Powered Process Meter
  • 1.5 Volt Drop (4.7 Volt Drop with Backlight)
  • Loop-Powered Backlight with Red Backlight for Alarm Conditions
  • NEMA 4X, IP65 Front
  • -40 to 158°F (-40 to 70°C) Operating Temperature Range
  • Free PC-Based USB Programming Software
  • 5-Digit Alphanumeric Top Line
  • 8-Digit Alphanumeric Bottom Line
  • Conformal Coated PCBs for Dust & Humidity Protection
  • Two Open Collector Outputs Standard
  • Optional Loop-Powered Solid State Relays
  • Optional 4-20 mA Analog Output
  • Relay Pump Alternation Based on Level and Runtime
  • Display Relay Runtime and Cycle Count
  • UL & C-UL 61010 Listed for Electrical Safety
  • UL & C-UL Listed as Intrinsically Safe and Nonincendive
  • ATEX and IECEx Certified as Intrinsically Safe
Product Options:

Maximum 25 characters

$380.00

Secured and trusted checkout with

The Precision Digital Loop Leader PD6606 is an intrinsically safe and nonincendive loop-powered meter that can be installed virtually anywhere because they get their power from the 4-20 mA loop and therefore require no separate power source. The PD6606 has a decimal dual line display which is typically used to display the process variable on the 5-digit alphanumeric top line and the units or a tag on the 8-digit alphanumeric bottom line.

Input

Input: 4-20 mA
Accuracy: ±0.02% of span ±1 count, Square root and programmable exponent: 10-100% FS
Voltage Drop: Without Backlight: 1.5 V maximum, With backlight: 4.5 V maximum
Equivalent Resistance: With backlight off: 75 Ω @ 20 mA, With backlight on: 225 Ω @ 20 mA
Input Overload: Over current protection to 1 A maximum
Temperature Drift: 25 PPM/°C from -40 to 75°C ambient
Function: PV1: Linear, square root, or programmable exponent PV2: Linear or Round Horizontal Tank
Low-Flow Cutoff: 0.0 to 999,999.9
HART Transparency: Analog input will not interfere with existing HART communications on the wired 4-20 mA signal

Display

Display: Dual-line LCD with backlight. Both lines 14-segment alphanumeric. Top: 0.7" (17.8 mm), Bottom: 0.4" (10.2 mm). Display may be programmed to turn red and flash a user-defined message on alarm condition.
Backlight: Powered by 4-20 mA loop. Intensity varies with signal level
PD6602 & PD6606:
Top line: 5 digits (-9999 to 99999) or 5 characters (all capital & most lower case letters)
Bottom line: 8 digits (-9,999,999 to 99,999,999; separated by commas) or 8 characters (all capital & most lower case letters)
Bargraph: None
PD6603 & PD6607:
Top line: -99FT 11IN 15/16 to 999FT 11IN 15/16
Bottom line: 8 digits (-9,999,999 to 99,999,999; separated by commas) or 8 characters (all capital & most lower case letters)
Bargraph: 20 segments, numeric percent indication at top
PD6604 & PD6608:
Top line: 5 digits (-9999 to 99999) or 5 characters (all capital & most lower case letters)
Bottom line: 8 digits (-9,999,999 to 99,999,999; separated by commas) or 8 characters (all capital & most lower case letters)
Bargraph: 20 segments, numeric percent indication at top
Decimal Point & Commas:
Top line: Up to four decimal places
Bottom line: Up to seven decimal places and commas to indicate 1000s (ie 88,987,628)
Dual-Scale Feature: The input can be displayed in different scales on the top and bottom lines. For instance, the top line could display the input in height and the bottom line could display that same input in volume.
Alarm Indication: Red backlight, flashing display, alarm symbol (!). Symbols are not available on bargraph models.
Alarm Message: On or Off; user programmable, 8 characters maximum. Displayed every 10 seconds for 1 second on bottom line.
Display Update Rate: Ambient > -10°C: 1 update/second
Ambient -20 C: 1 update/2 seconds
From -20°C to -40°C the update rate slows down 1 second for every -2°C (e.g. at -24°C, 1 update/4 seconds).
Overrange: Top: 99999; Bottom: 99,999,999 (flashing)
Underrange: Top: -9999; Bottom: -9,999,999 (flashing)

General

Environmental: Operating temperature range:
-40 to 75°C for safe area products
-40 to 70°C for hazardous area products
Storage temperature range: -40 to 85°C
Relative humidity: 0 to 90% non-condensing. Printed circuit boards are conformally coated.
Programming Method: Front panel & Free PC-based USB programming software
Enclosure & Materials: Enclosure: 1/8 DIN, IP65, NEMA 4X front panel, high impact plastic, NORYL® polyphenylene ether & polystyrene blend (PPE PS) resin, UL 94V-0, Color: gray, Gasket: silicone rubber, Faceplate: LEXAN® polycarbonate (PC) film, Buttons: silicone rubber
Noise Filter: Averages the input signal over a period of time between 1 and 16 seconds to dampen the effects of a noisy signal that causes a jumpy display.
Recalibration: Recalibration is recommended at least every 12 months.
Max/Min Display: Max/min readings reached by the process are stored until reset by the user or until power to the meter is turned off.
Tare: Zeros out display
Password: Programmable password restricts modification of programmed settings.
Non-Volatile Memory: All programmed settings are stored in nonvolatile memory for a minimum of ten years if power is lost.
Normal Mode Rejection: 64 dB at 50/60 Hz
Connections: Removable screw terminals accept 12 to 22 AWG wire.
DI Digital Input Contacts: 2.1 VDC on contact. Connect normally open contacts across DI+ and DI
DI Digital Input Logic Levels: Logic High: 2.4 to 30 VDC (max)
Logic Low: 0 to 0.9 VDC
Tightening Torque: Screw terminal connectors: 4.5 lb-in (0.5 Nm)
Mounting screws: 8.0 lb-in max. (0.9 Nm)
Overall Dimensions: 4.68"x 2.45"x 3.79" (119 mm x 62 mm x 96 mm) (W x H x D)
Weight: 8.7 oz (247g) with option board
Warranty: 3 years parts and labor

Common Open Collector & Relay (Alarm) Specifications

High or Low Alarm: User programmable for high or low alarm
Alarm Deadband: 0-100% FS, user programmable
On & Off Time Delay: 0 to 9,999 seconds
Fail-Safe Operation: Independent for each open collector and relay
Alarm Operation: Automatic, Automatic with manual override, Latching (manual reset anytime), Latching with reset after cleared (manual reset only after alarm has cleared)
Alarm Indication: Red backlight, flashing display, alarm symbol (!); (symbols not available on bargraph models)
Alarm Message: On or Off; User programmable, 8 characters maximum. Displayed every 10 seconds for 1 second on bottom line
Alarm Acknowledge: Front panel ACK button or external digital input resets output and screen indication
Auto Initialization: When power is applied to the meter, open collectors and relays will reflect the state of the input to the meter
Timer Output: One-shot or Continuous
Off Time Delay: 1 sec to 99:59:59 (hrs:min:sec)
On Time: 1 sec to 99:59:59 (hrs:min:sec)
Stopwatch: Output turns on when started and off when stopped

Open Collector Outputs

Rating: Two NPN, Isolated open collector, 30 VDC @ 150 mA max
Output Assignment: Pulse, Alarm, Timer, Stopwatch on/off, or Disable
Pulse Output Source: PV (PV1, PV2) or Test Frequency
Pulse Output Factor: 0.000001 to 999,999.9
Pulse Width: 0.5 ms @ 1 kHz; 500 ms @ 1 Hz; 50% duty cycle
Pulse Output Frequency: 1,000 Hz maximum
Quadrature Pulse Output: Available for Output 2 (90° behind Output 1)
Alarm Output Source: Assign to PV (PV1, PV2) or Digital Input

Solid State Relays

Rating: Resistive Load: 250 VAC/DC @ 1 A
Inductive Load: 75 VA @ 0.6 A, 250 VAC/DC max (Safe Area only)
Noise Suppression: Metal oxide varistors across outputs
Relay Assignment: Pump Alternation, Alarm, Timer, Stopwatch on/off, or Disable
Alarm Output Source: Assign to PV (PV1, PV2) or Digital Input
Pump Alternation: Relays will alternate with each pump cycle and alternation can be based on elapsed time. Pump alternation time can be programed for: 0 to 999:59 (hrs:min)
Relay (Pump) Runtime: Meter will keep track of how long each relay (pump) has operated and display this information
Relay (Pump) Cycles: Meter will keep track of how many times the relays (pumps) have cycled and display this information

4-20 mA Transmitter Output

Accuracy: ±0.05% FS ±0.001mA
Output Source: PV1, PV2, re-transmit; reverse scaling allowed
Scaling Range: 1.00 to 23.0 mA
Disable: High impedance state, less than 1 mA
Calibration: Factory calibrated 4.00 to 20.00 mA
Underrange: 1.0 mA, 3.5 mA, or 3.8 mA (If input < 3.5 mA), or Off; user selectable
Overrange: 20.5 mA, 20.8 mA, or 23.0 mA (If input > 20.5 mA), or Off; user selectable
Isolation: 500 V input-to-output
Temperature Drift: 0.5 μA/°C max from -40 to 75°C ambient
External Loop Power Supply: 7.0 VDC to 30.0 VDC maximum
Output Loop Resistance: 10-750 Ω @ 24 VDC; 100-1100 Ω @ 30 VDC

Hazardous Area Approvals

ATEX: II 1G, Ex ia IIC T4 Ga, Ta = -40°C to +70°C
    Certificate number: CML 17ATEX2015X
IECEx: Ex ia IIC T4 Ga, Tamb = -40°C to +70°C
    Certificate number: IECEx CML 17.0008X
UL & C-UL Listed as Intrinsically Safe and Nonincendive:
    Class I, Division 1, Groups A, B, C and D T4,
    Class I, Division 2, Groups A, B, C and D T4
    Ex ia IIC T4 (Canada); Class I Zone 0, Zone 1
    AEx ia IIC T4 (U.S.)
    Class I Zone 2, Group IIC T4 (U.S.)
    PROCESS CONTROL EQUIPMENT FOR USE IN HAZARDOUS LOCATIONS
UL & C-UL 61010 Listed for Electrical Safety and Type 4X Environmental:
    Standards for Safety:
    IEC 61010-1:2010 (3rd Edition);
    UL 61010-1, 3rd Edition;
    CAN/CSA-C22.2 No. 61010-1-12, 3rd Edition;
    Additional Standards:
    UL 50E