PIECAL 422Plus Diagnostic Thermocouple and mA Calibrator

SKU
PIE-422Plus
Manufacturer:
PIECAL
PIECAL

Key Features:

  • Two Calibrators in One!
  • Troubleshoot loop problems
  • Calibrate directly in temperature (°C & °F)
  • Calibration Lab Accurate & Stable
  • Verify Heat Treating Uniformity Survey Recorders and perform System Accuracy Tests
  • Checkout all your 4 to 20 mA loops & instruments
  • Easy to use in the Plant, Field or Shop
  • Fast calibration with automatic output stepping
Product Options:
$2,229.00

Secured and trusted checkout with

The PIECAL’S 422Plus Diagnostic RTD and mA Calibrator uncovers of unseen loop problems. Current that is not controlled by the transmitter or other current control elements is presented as leakage on the calibrator’s display.

Features

  • • Two Calibrators in One!
    Calibrate all your thermocouple instruments AND your milliamp loops with the PIE 422Plus. It has all the functions of a 14 type thermocouple calibrator and can source 0 to 24 milliamps or simulate a two wire transmitter like a milliamp calibrator. You may also perform stand alone calibrations of two wire transmitters by simultaneously supplying the thermocouple input signal while supplying the 24 volts to power up the transmitter and monitoring the milliamp output signal. Powers HART™ transmitters with built-in 250 ohm resistor simplifying hookups with HART communicators.
  • Troubleshoot loop problems
    Quickly diagnose ground fault and current leakage with the patented loop diagnostic technology (US Patent# 7,248,058)
  • Calibrate directly in temperature (°C & °F)
    Stop carrying around a millivolt source and thermocouple tables. The PIECAL 422Plus works with the thermocouples you use including types J, K, T, E, R, S, B, N, G, C, D, L (J-DIN), U (T-DIN) and P (Platinel II). Easily set any value quickly to within 0.1° with the adjustable “EZ-DIAL” plus store any three temperatures for instant recall with the EZ-CHECK™ switch. You may also calibrate from -13.000 to +80.000 mV. Connect your thermocouple and the PIE 422Plus measures the probe in degrees C or F. Secondary display shows the millivolt value corresponding to the thermocouple temperature.
  • Calibration Lab Accurate & Stable
    The internal cold junction thermistor is accurate to ±0.05°C and is traceable to NIST. The sensor is thermally bonded to an isothermal mass including brass blocks with screw terminals for connection of bare thermocouple wires along with a miniature thermocouple connector for fast connections. An extremely stable voltage reference and low drift components make it more accurate than most other handheld & benchtop thermocouple calibrators.
  • Verify Heat Treating Uniformity Survey Recorders and perform System Accuracy Tests
    The PIE 422Plus is capable of meeting the requirements of an AMS 2750 Field Test Instrument when certified by an accredited laboratory.
  • Checkout all your 4 to 20 mA loops & instruments
    With the built-in milliamp calibrator you can check, calibrate and measure all your current signal instruments in a 4 to 20 milliamp loop. It can be used at any access point in your loop. Source & Read 0.000 to 24.000 mA, Simulate a 2 Wire Transmitter or use the PIE 422Plus to simultaneously power your 2 Wire Transmitter and measure its output while simulating the sensor input.
  • Easy to use in the Plant, Field or Shop With the PIE 422Plus you can check & calibrate all your thermocouple instruments, measure thermocouple Sensors, and calibrate 4 to 20 milliamp instruments. Automatic indication of connections on the display for simple hookups. Carry it without worry – it comes protected with a rubber boot and rugged, low profile switches. Easy to operate even in dark areas with the backlit display.
  • Fast calibration with automatic output stepping
    Choose between 2, 3, 5, 11 and 21 steps to automatically increment the output in 100%, 50%, 25%, 10% or 5% of span. Select the step time to match your system from 5, 6, 7, 8, 9, 10, 15, 20, 25, 30 and 60 seconds.

 

General

Operating Temperature
Range

-25 to 60 °C (-10 to 140 °F)

Relative Humidity Range

10 % ≤RH ≤90 % (0 to 35 °C), Non-condensing

10 % ≤RH≤ 70 % (35 to 60 °C), Non-condensing

Temperature Drift

± 0.01% of span outside of 23°C ±10 °C (73°C ±18 °F)

Size

5.63 x 3.00 x 1.60 in, 143 x 76 x 41 mm (L x W x H)

Weight

12.1 ounces, 0.34 kg (including boot & batteries)

Batteries

Four “AA” Alkaline 1.5V (LR6)

Battery Life

25 Hours Thermocouple, 8 Hours milliamp

Isolation: Voltage

60V rms between all milliamp functions/Read V DC

and Source V DC/Thermocouple

Normal Mode Rejection

50/60 Hz, 50 dB

Common Mode Rejection

50/60 Hz, 120 dB

Optional NiMh
Rechargeable battery kit

Charger, four NiMh batteries [Part # 020-0103]

Low Battery

Low battery indication with nominal 1 hour of
operation left

Protection against misconnection

Over-voltage protection to 60 V dc (rated for 30 seconds)

Display

High contrast graphic liquid crystal display. LED
backlighting for use in low lit areas.

Read mA

Ranges and Resolution

0.000 to 24.000 mA or -25.00 to 125.00% of 4-20 mA

Accuracy

≤ ± (0.02 % of Reading + 0.003 mA)

Voltage burden

≤ 2V at 24 mA

Overload/Current limit protection

25 mA nominal

Source mA / Power & Measure Two Wire Transmitters & PWRM LEAK

Ranges and Resolution

0.000 to 24.000 mA or -25.00 to 125.00% of 4-20 mA

Accuracy

≤ ± (0.02 % of Reading + 0.003 mA)

Loop compliance voltage

≥ 24 DCV @ 20.00mA

Loop drive capability

1200 Ω at 20 mA for 15 hours nominal;
950 Ω with Hart Resistor or leak detection running

mA 2-Wire Transmitter Simulation

Accuracy

Same as Source/Power & Measure

Voltage burden

≤ 2V at 20 mA

Overload/Current limit protection

24 mA nominal

Loop voltage limits

2 to 60 VDC (fuse-less protected from reverse polarity connections)

Source Thermocouple

Accuracy

±(0.008% of Reading + 0.006 mV)

Cold Junction
Compensation

± 0.09°F (±0.05 °C) - Thermistor  traceable to NIST for 11 years

Millivolt Range

-13.000 to 80.000 mV

Output Impedance

< 0.3 Ohms

Source Current

> 20 mA (drives 80 mV into 10 Ohms)

Noise

≤ 4 microvolts p-p for frequencies of 10 Hz or below

ReadThermocouple

Accuracy

±(0.008% of Reading + 0.006 mV)

Cold Junction

Compensation

± 0.09°F (±0.05 °C) - Thermistor  traceable to NIST for

11 years

Millivolt Range

-13.000 to 80.000 mV

Input Impedance

> 10 Megohms

Open Thermocouple

Threshold

Pulse

 

10,000 Ohms nominal

< 10 microamp pulse for 400 milliseconds

Normal Mode Rejection

50/60 Hz, 50 dB

Common Mode Rejection

50/60 Hz, 120 dB

 

Thermocouple Ranges & Accuracies

Based on ≤ ± (0.008  % of Reading + 0.006 mV)

T/C

Degrees C Range

°C

Degrees F Range

°F

T/C Material

J

-200.0 to -180.0

±0.3°

-328.0 to -292.0

±0.5°

+Iron

-Connstantan

-180.0 to -50.0

±0.2°

-292.0 to -58.0

±0.4°

-50.0 to 500.0

±0.1°

-58.0 to 932.0

±0.2°

500.0 to 1200,0

±0.2°

932.0 to 2192.0

±0.4°

 

K

-230.0 to -100.0

±0.6°

-382.0 to -148.0

±1.1°

+ Chromel®

-Alumel®

-100.0 to 1050.0

±0.2°

-148.0 to 1922.0

±0.4°

1050.0 to 1371.1

±0.3°

1922.0 to 2500.0

±0.5°

 

T

-260.0 to -200.0

±1.0°

-436.0 to -328.0

±1.8°

+Copper

-Constantan

-200.0 to -50.0

±0.5°

-328.0 to -58.0

±0.9°

-50.0 to 0.0

±0.2°

-58.0 to 32.0

±0.4°

0.0 to 400.0

±0.1°

32.0 to 752.0

±0.2°

 

E

-240.0 to -200.0

±0.4°

-400.0 to -328.0

±0.7°

+Chromel

-Constantan

-200.0 to -100.0

±0.2°

-328.0 to -148.0

±0.4°

-100.0 to 850.0

±0.1°

-148.0 to 1562.0

±0.2°

850.0 to 1000.0

±0.2°

1562.0 to 1832.0

±0.4°

 

R

-18.3 to 250.0

±1.2°

-1.0 to 482.0

±2.2°

+Pt/13Rh

-Platinum

250.0 to 750.0

±0.6°

482.0 to 1382.0

±1.1°

750.0 to 1600.0

±0.5°

1382.0 to 2192.0

±0.9°

1600.0 to 1767.8

±0.6°

2192.0 to 3214.0

±1.1°

 

S

-18.3 to 100.0

±1.2°

-1.0 to 212.0

±2.1°

+Pt/10Rh

-Platinum

100.0 to 400.0

±0.8°

212.0 to 752.0

±1.4°

400.0 to 1700.0

±0.6°

752.0 to 3092.0

±1.1°

1700.0 to 1767.8

±0.7°

3092.0 to 3214.0

±1.3°

 

B

315.6 to 550.0

±1.8°

600 to 1022.0

±3.2°

+Pt/30Rh

-Pt/6Rh

550.0 to 900.0

±1.1°

1022.0 to 1652.0

±2.0°

900.0 to 1150.0

±0.7°

1652.0 to 2102.0

±1.3°

1150.0 to 1820.0

±0.6°

2102.0 to 3308.0

±1.1°

 

 

T/C

Degrees C Range

°C

Degrees F Range

°F

T/C Material

N

-230.0 to -180.0

±1.0°

-382.0 to -292.0

±1.8°



+Nicrosil

-Nisil

-180.0 to -50.0

±0.5°

-292.0 to -58.0

±0.9°

-50.0 to 1100.0

±0.2°

-58.0 to 2012.0

±0.4°

1100.0 to 1300.0

±0.3°

2012.0 to 2372.0

±0.5°

 

G
(W)

100.0 to 150.0

±1.2°

212.0 to 302.0

±2.2°



+Tungsten

-W26/Re

150.0 to 400.0

±0.8°

302.0 to 752.0

±1.4°

400.0 to 1700.0

±0.4°

752.0 to 3092.0

±0.7°

1700.0 to 2320.0

±0.7°

3092.0 to 4208.0

±1.3°

 

C
(W5)

-1.1 to 1500

±0.5°

30.0 to 2372.0

±0.9°



+W5/Re

-W26/Re

1500 to 1900

±0.6°

2372.0 to 3452.0

±101°

1900.0 to 2100.0

±0.7°

3452.0 to 3812.0

±1.3°

2100.0 to 2320.0

±0.9°

3812.0 to 4208.0

±1.6°

 

D
(W3)

-1.1 to 50.0

±0.6°

30.0 to 122.0

±1.1°



+W3/Re

-W25/Re

50.0 to 1400.0

±0.4°

122.0 to 2552.0

±0.7°

1400.0 to 1800.0

±0.5°

2552.0 to 3272.0

±0.9°

1800.0 to 2320.0

±0.9°

3272.0 to 4208.0

±1.6°

 

P

Platinel®

0.0 to 1000.0

±0.2°

32.0 to 1832.0

±0.4°

+Pd55/Pt31/Au14

-Au65/Pd35

1000.0 to 1395.0

±0.3°

1832.0 to 2543.0

±0.5°

 

DIN Colors

L

J-DIN

-200.0 to -50.0

±0.2°

-328.0 to -58.0

±0.4°


+Iron

-Connstantan

-50.0 to 500.0

±0.1°

-58.0 to 932.0

±0.2°

 

500.0 to 900.0

±0.2°

932.0 to 1652.0

±0.4°

 

U

T-DIN

-200.0 to -75.0

±0.3°

-328.0 to -103.0

±0.5°


+Copper

-Constantan

-75.0 to 100.0

±0.2°

-103.0 to 212.0

±0.4°

 

100.0 to 600.0

±0.1°

212.0 to 1112.0

±0.2°