PIECAL 311Plus Diagnostic RTD and mA Calibrator

SKU
PIE-311Plus
Manufacturer:
PIECAL
PIECAL

Key Features:

  • Two Calibrators in One!
  • Troubleshoot loop problems
  • Calibrate directly in temperature (°C & °F)
  • Measure RTD sensors
  • Compatible with ALL process instruments
  • Checkout all your 4 to 20 mA loops & instruments
  • Easy to use in the Plant, Field or Shop
  • Fast calibration with automatic output stepping
Product Options:
$2,379.00

Secured and trusted checkout with

PIECAL’S 311Plus Diagnostic RTD and mA Calibrator is designed for the discovery of unseen loop problems. Current that is not controlled by the transmitter or other current control elements will be shown as leakage on the calibrator’s display.

Features

  • • Two Calibrators in One!
    Calibrate all your RTD instruments AND your milliamp loops with the PIE 311Plus. It has all the functions of a 12 type RTD calibrator and can source 0 to 24 milliamps or simulate a two wire transmitter like a milliamp calibrator. You may also perform stand alone calibrations of two wire transmitters by simultaneously supplying the thermocouple input signal while supplying the 24 volts to power up the transmitter and monitoring the milliamp output signal. Powers HART™ transmitters with built-in 250 ohm resistor simplifying hookups with HART communicators.
  • Troubleshoot loop problems
    Quickly diagnose ground fault and current leakage with the patented loop diagnostic technology (US Patent# 7,248,058)
  • Calibrate directly in temperature (°C & °F)
    Stop carrying around a decade box and RTD resistance tables. The PIE 311Plus works with the RTDs you use including Platinum 10, 50, 100, 200, 500 & 1000 Ohm (alpha = 3850), Platinum 100 Ohm (alpha = 3902, 3916, 3926), Copper 10 & 50 Ohm, and Nickel 120 Ohm. Or calibrate from 0.000 to 400.000 and 0.00 to 4000.00 Ohms. For RTDs the fixed or pulsed sensor current is measured by the calibrator.
  • Measure RTD sensors
    Trouble shoot sensor connections and find broken wires with patented technology. Connect your two, three or four wire RTDs and the PIE 311Plus automatically detects the connections and measures the RTD in degrees C or F. Secondary display shows the resistance value corresponding to the RTD temperature.
  • Compatible with ALL process instruments
    No competitor’s calibrator is compatible with as many process instruments! Connect directly to the temperature inputs of transmitters, PLCs, DCS & multichannel recorders to verify their outputs or displays. RTD simulation works with older instruments with fixed excitation currents and newer multichannel instruments that switch the excitation current between input channels.
  • Checkout all your 4 to 20 mA loops & instruments
    With the built-in milliamp calibrator you can check, calibrate and measure all your current signal instruments in a 4 to 20 milliamp loop. It can be used at any access point in your loop. Source & Read 0.000 to 24.000 mA, Simulate a 2 Wire Transmitter or use the PIE 311Plus to simultaneously power your 2 Wire Transmitter and measure its output while simulating the sensor input.
  • Easy to use in the Plant, Field or Shop
    With the PIE 311Plus you can check & calibrate all your RTD instruments, measure RTD Sensors, and calibrate 4 to 20 milliamp instruments. Automatic indication of connections on the display for simple hookups. Carry it without worry – it comes protected with a rubber boot and rugged, low profile switches. Easy to operate even in dark areas with the backlit display.
  • Fast calibration with automatic output stepping
    Choose between 2, 3, 5, 11 and 21 steps to automatically increment the output in 100%, 50%, 25%, 10% or 5% of span. Select the step time to match your system from 5, 6, 7, 8, 9, 10, 15, 20, 25, 30 and 60 seconds.

 

General

Operating Temperature
Range

-25 to 60 °C (-10 to 140 °F)

Relative Humidity Range

10 % ≤RH ≤90 % (0 to 35 °C), Non-condensing

10 % ≤RH≤ 70 % (35 to 60 °C), Non-condensing

Temperature Drift

± 0.01% of span outside of 23°C ±10 °C (73°C ±18 °F)

Size

5.63 x 3.00 x 1.60 in, 143 x 76 x 41 mm (L x W x H)

Weight

12.1 ounces, 0.34 kg (including boot & batteries)

Batteries

Four “AA” Alkaline 1.5V (LR6)

Battery Life

25 Hours RTD, 8 Hours milliamp

Isolation:   Voltage

60V rms between all milliamp functions and Source/ Read RTD/Ohms

Normal Mode Rejection

50/60 Hz, 50 dB

Common Mode Rejection

50/60 Hz, 120 dB

Optional NiMh
Rechargeable battery kit

Charger,  four NiMh batteries [Part # 020-0103]

Low Battery

Low battery indication with nominal 1 hour of operation left

Protection against misconnection

Over-voltage protection  to 60 V dc (rated for 30 seconds)

Display

High contrast graphic liquid crystal display. LED backlighting for use in low lit areas.

Read mA

Ranges and Resolution

0.000 to 24.000 mA or -25.00 to 125.00% of 4-20 mA

Accuracy

≤ ± (0.02 % of Reading + 0.003 mA)

Voltage burden

≤ 2V at 24 mA

Overload/Current limit protection

25 mA nominal

Source mA / Power & Measure Two Wire Transmitters & PWRM LEAK

Ranges and Resolution

0.000 to 24.000 mA or -25.00 to 125.00% of 4-20 mA

Accuracy

≤ ± (0.02 % of Reading + 0.003 mA)

Loop compliance voltage

≥ 24 DCV @ 20.00mA

Loop drive capability

1200 Ω at 20 mA for 15 hours nominal;
950 Ω with Hart Resistor or leak detection running

mA 2-Wire Transmitter Simulation

Accuracy

Same as Source/Power & Measure

Voltage burden

≤ 2V at 20 mA

Overload/Current limit protection

24 mA nominal

Loop voltage limits

2 to 60 VDC (fuse-less protected  from reverse polarity connections)

Read Ohms & RTD

Accuracy

±(0.015% of Reading + 0.05 Ohms)

Resistance Ranges

0.00 to 401.00, 0.0 to 4010.0 Ohms

Excitation Current

0.9 mA to 401 Ohms, 0.4 mA to 4010 Ohms (nominal)

Source Ohms & RTD

3 & 4 Wire Accuracy

From 1 to 10.2 mA

External Excitation Current

 

Below 1 mA of External

Excitation Current

2 Wire Accuracy

 

±(0.015% of Reading + 0.05 Ohms)

 

                                      0.025 mV          
±(0.015% of Rdg + mA Excitation Current + 0.05 Ohms)

 

Add 0.1 Ohms to 3 Wire & 4 Wire Accuracy

Resistance Ranges

0.00 to 401.00, 0.0 to 4010.0 Ohms

Allowable Excitation
Current Range

0 to 400 Ohm: 10.2 mA max; steady or pulsed/intermittent
401 to 4000 Ohms: 1 mA max; steady or pulsed/intermittent

Pulsed Excitation
Current Compatibility

DC to 0.01 second pulse width

 

RTD Ranges & Accuracies

Table based on 3 & 4 Wire RTD Accuracy:
≤ ± (0.015 % of Reading +0.05 Ohms)
[Read based on 1.0 mA of fixed excitation current]

RTD
Type

Alpha

Degrees C
Range

°C

Degrees F
Range

°F

Pt 100 Ohm
DIN/IEC/JIS 1989
ITS-90

1.3850
(0.00385)

-200.00 to -150.00
-150.00 to 360.00
360.00 to 740.00
740.00 to 850.00

±0.1°
±0.2°
±0.3°
±0.4°

-328.0 to -238.00
-238.00 to 660.00
660.00 to 1364.00
1364.00 to 1562.00

±0.2°
±0.4°
±0.6°
±0.7°

Pt 10 Ohm
DIN/IEC/JIS 1989
Based on
ITS-90

1.3850
(0.00385)

-200.00 to -120.00
-120.0 to 210.00
210.00 to 370.00
370.00 to 650.00
650.00 to 850.00

±1.2°
±1.4°
±1.5°
±1.7°
±1.9°

-328.00 to -184.00
-184.00 to 410.00
410.00 to 698.00
698.00 to 1202.00
1202.00 to 1562.00

±2.2°
±2.6°
±2.8°
±3.1°
±3.4°

Pt 50 Ohm
DIN/IEC/JIS 1989
ITS-90

1.3850
(0.00385)

-200.00 to 200.00
200.00 to 550.00
550.00 to 850.00

±0.3°
±0.4°
±0.5°

-328.00 to 392.00
392.00 to 1022.00
1022.00 to 1562.00

±0.6°
±0.8°
±1.0°

Pt 200 Ohm
DIN/IEC/JIS 1989
ITS-90

1.3850
(0.00385)

-200.00 to -120.00
-120.00 to 180.00
180.00 to 450.00
450.00 to 680.00
680.00 to 850.00

±0.1°
±0.1°
±0.2°
±0.2°
±0.3°

-328.00 to -184.00
-184.00 to 356.00
356.00 to 842.00
842.00 to 1256.00
1256.00 to 1562.00

±0.1°
±0.2°
±0.3°
±0.4°
±0.5°

Pt 500 Ohm
DIN/IEC/JIS 1989
ITS-90

1.3850
(0.00385)

-200.00 to -90.00
-120.00 to 180.00
180.00 to 450.00
450.00 to 680.00
680.00 to 850.00

±0.1°
±0.1°
±0.2°
±0.2°
±0.3°

-328.00 to -194.00
-184.00 to 356.00
356.00 to 842.00
842.00 to 1256.00
1256.00 to 1562.00

±0.1°
±0.2°
±0.3°
±0.4°
±0.5°

Pt 1000 Ohm
DIN/IEC/JIS 1989
ITS-90

1.3850
(0.00385)

-200.00 to 170.00
170.00 to 470.00
470.00 to 730.00
730.00 to 850.00

±0.1°
±0.1°
±0.2°
±0.2°

-328.00 to 338.00
338.00 to 878.00
878.00 to 1346.00
1346.00 to 1562.00

±0.1°
±0.2°
±0.3°
±0.4°

Pt 100 Ohm
(Burns)

1.3902
(0.003902)

-195.61 to -100.00
-100.00 to 370.00
370.00 to 648.90

±0.1°
±0.2°
±0.3°

-320.10 to -148.00
-148.00 to 698.00
698.00 to 1200.00

±0.3°
±0.4°
±0.6°

Pt 100 Ohm
(Old JIS
1981)

1.3916
(0.003916)

-200.00 to -140.00
-140.00 to 130.00
130.00 to 370.00
370.00 to 648.90

±0.1°
±0.2°
±0.2°
±0.3°

-328.00 to -220.00
-220.00 to 266.00
266.00 to 698.00
698.00 to 1200.00

±0.2°
±0.3°
±0.4°
±0.6°

Pt 100 Ohm
(US Lab)

1.3926
(0.003926)

-200.00 to -140.00
-140.00 to 130.00
130.00 to 380.00
380.00 to 610.00
610.00 to 850.00

±0.1°
±0.2°
±0.2°
±0.3°
±0.4°

-328.00 to -220.00
-220.00 to 266.00
266.00 to 716.00
716.00 to 1130.00
1130.00 to 1562.00

±0.2°
±0.3°
±0.4°
±0.5°
±0.7°

Copper 10
Ohm (Minco)

1.4274
(0.004274)

-200.00 to -150.00
-150.00 to 90.00
90.00 to 260.00

±1.2°
±1.3°
±1.4°

-328.00 to -238.00
-238.00 to 194.00
194.00 to 500.00

±2.2°
±2.4°
±2.4°

Copper 50
Ohm

1.4280
(0.00428)

-50.00 to 150.00

±0.3°

-58.00 to 302.00

±0.5°

Ni 120 Ohm
(Pure)

1.6720
(0.00672)

-80.00 to 260.00

±0.1°

-112.00 to 500.00

±0.2°

Data Sheet

PIECAL 311Plus Data Sheet

Manuals

Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account