Replacing the MIT400 series, Megger has introduced their MIT400/2 1004-731 Insulation Tester. The MIT400/2 1004-731 is equipped with 250V, 500V and 1000V test voltages and a 200G Ω range. Likewise, the process of insulation testing is improved with feedback controlled test voltages to limit over-voltage to 2% while boasting a 2% accuracy.
Users can execute continuity tests even faster as a single auto-ranging 0.01Ω to 1.0 MΩ function substitutes the “ohms” and “kOhms” ranges. Supplied with red and black silicone leads and suited with a CAT IV 600V / CAT III 1000V safety rating, the MIT400/2 1004-731 is the first installment in Megger’s MIT400/2 series of insulation testers.
All quoted accuracies are at +20 °C. | |||
Insulation: | |||
Test voltage | |||
Nominal: MIT400/2 | 250 V, 500 V, 1000 V | ||
MIT410/2, 420/2, 430/2 | 50 V, 100 V, 250 V, 500 V, 1000 V | ||
Insulation accuracy | |||
50 Volts. | 10 GΩ | ± 2% | ± 2 digits ± 4.0% per GΩ |
100 Volts. | 20 GΩ | ± 2% | ± 2 digits ± 2.0% per GΩ |
250 Volts. | 50 GΩ | ± 2% | ± 2 digits ± 0.8% per GΩ |
500 Volts. | 100 GΩ | ± 2% | ± 2 digits ± 0.4% per GΩ |
1000 Volts | 200 GΩ | ± 2% | ± 2 digits ± 0.2% per GΩ |
Service Error: BS EN 61557-2 (2007). | |||
50V, ± 2.0% ± 2d, 100 kΩ - 900 kΩ ± 10.5% | |||
100V, ± 2.0% ± 2d, 100 kΩ - 900 kΩ ± 10.3% | |||
250V, ± 2.0% ± 2d, 100 kΩ - 900 kΩ ± 10.3% | |||
500V, ± 2.0% ± 2d, 100 kΩ - 900 kΩ ± 10.3% | |||
1000V, ± 2.0% ± 2d, 100 kΩ - 900 kΩ ± 11.5% | |||
Display range | Analogue: 1 GΩ full scale | ||
Resolution | 0.1 kΩ | ||
Short circuit/charge current | 2 mA +0% -50% to EN 61557-2 (2007) | ||
Open circuit voltage insulation | -0% +2% ± 2V | ||
Test current | 1 mA at min. pass value of insulation to a maximum of 2 mA max. | ||
Leakage (not MIT400/2) | 10% ±3 digits | ||
Voltage | 3% ±3 digits ±0.5% of rated voltage | ||
Timer control (not MIT400/2) | 60 second countdown timer | ||
Note | Above specifications only apply when high quality silicone leads are being used. | ||
Continuity: | |||
Continuity measurement | 0.01 Ω to 1000 kΩ | ||
Continuity accuracy | ± 3% ± 2 digits (0 to 100 Ω ) ±5% ±2 digits (100 to 500kΩ) (500kΩ to 1MΩ unspecified) Service Error: BS EN 61557-4 (2007) - ± 2.0%, 0.1 Ω - 2 Ω ± 6.8% | ||
Open circuit voltage | 5 V ± 1 V | ||
Test current | 200 mA (–0 mA +20 mA) (0.01 Ω to 4 Ω) | ||
Polarity (not MIT400/2) | Single polarity (Default) / Dual polarity (configurable on setup). | ||
Lead resistance | Null up to 9.00 Ω | ||
Voltage: | |||
Voltage range | AC: 10 mV to 600 V TRMS sinusoidal (15 Hz to 400 Hz) DC: 0 to 600 V | ||
Volt range accuracy | AC: ±2% ±1 digit DC: ±2% ±2 digit Service Error: BS EN 61557-1 (2007) - ± 2.0% ± 2d, 0 V – 300 V AC/DC ± 5.1% | ||
Waveform | Unspecified range: 0 – 10 mV (15 to 400 Hz) For non-sinusoidal waveforms additional specifications apply Non-sinusoidal waveforms: ±3% ± 2 digits >100 mV to 600 V TRMS ±8% ± 2 digits 10 mV to 100 mV TRMS | ||
Frequency: (not MIT400/2) | |||
Frequency measurement range | 15 Hz - 400 Hz | ||
Frequency measurement accuracy | ±0.5% ± 1digit (100 Hz to 400 Hz unspecified) | ||
Capacitance measurement: | MIT420/2, MIT430/2 | ||
MIT420/2, MIT430/2 Capacitance measurement | 1 nF to 10 μF | ||
Capacitance measurement accuracy | ± 5.0% ± 2 digits (0.1 nF – 1 nF unspecified) | ||
Storage: | |||
Result storage (MIT420/2 and MIT430/2): | |||
Storage capacity | >1000 test results | ||
Data download (MIT430/2 only) | Bluetooth® wireless Bluetooth® Class II | ||
Range | up to 10 m | ||
Power supply | 6 x 1.5 V cells type IEC LR6 (AA, MN1500, HP7, AM3 R6HP) Alkaline 6 x 1.2 V NiMH rechargeable cells may be used | ||
Battery life | 3000 insulation tests with duty cycle of 5 sec ON /55 sec OFF @ 1000 V into 1 MΩ | ||
Charger (Optional): | 12-15 V dc (accessory interface) | ||
Dimensions | Instrument 228 mm x 108 mm x 63 mm (9.00 in x 4.25 in x 2.32 in) | ||
Weight | 600 g (MIT400/2), (1.32 lb) | ||
Weight (instrument and case) | 1.75 kg (3.86 lb) | ||
Fuse | Use only 1 x 500 mA (FF) 1000 V 32 x 6 mm ceramic fuse of high breaking capacity HBC 30 kA minimum. Glass fuses MUST NOT be fitted. | ||
Safety protection | The instruments meet EN 61010-1 (1995) to 600 V phase to earth, Category IV. Refer to safety warnings supplied. | ||
EMC | In accordance with IEC 61326 including amendment No.1 | ||
Temperature co-efficient | <0,1% per °C up to 1 GΩ <0.1% per °C per GΩ above 1 GΩ | ||
Environmental: | |||
Operating temperature range and humidity | -10 to +55 °C 90% RH at 40 °C max. | ||
Storage temperature range | -25 to +70 °C | ||
Calibration temperature | +20 °C | ||
Maximum altitude | 2000 m | ||
IP rating | IP 54 | ||
The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc and is used under licence. |
Write Your Own Review
- • Commercial Avionics
- • Battery Powered Traction and Lifting Equipment
- • Cable Testing
- • Military Land, Marine and Air Communications
- • Component Testing
- • Manufacturing/Production Line Goods
- • Electrostatic Measurement
- • Motoring Testing
- • ESD
- • Panel Building