We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
Available from 30 to 5000 PSIG, MadgeTech has introduced their PRTC210 Pressure and Temperature Data Logger with Thermocouple Connection with a 1/8 inch NPT fitting.
The PRTC210 is equipped with a real time clock and battery life for up to 2 years. More still, the logger has a high-speed download and the ability to measure and record data for up to 10,922 readings per channel. The non-volatile solid state memory delivers utmost data security, even if the battery becomes discharged.
The PRTC210 can be started and stopped right from a PC and data retrieval is effortless and fast. Users plug the PRTC210 into an empty COM or USB port and the easy to use software does the rest. Compact and portable, MadgeTech’s PRTC210 is the ideal logger for use in factory settings.
*Thermocouple Probe sold separately
TEMPERATURE
Remote Channel Temperature Sensor | Thermocouple Types J, K, T, E, R, S, B, N |
---|---|
Remote Channel Temperature Range | Thermocouple Dependent |
Remote Channel Temperature Resolution | Thermocouple Dependent |
Remote Channel Temperature Calibrated Accuracy | Thermocouple Dependent |
PRESSURE
Pressure Sensor | Internal semiconductor |
---|---|
Pressure Range | 0 to 30, 100, 300, or 500 PSIA/G; 0 to 1000 or 5000 PSIA |
Pressure Resolution | See Specifications Sheet |
Pressure Calibrated Accuracy | 2 %FSR, 0.25 % at 25 °C (77 °F) |
GENERAL
Memory | 10,922 readings per channel |
---|---|
Reading Rate | 1 reading every 2 seconds to 1 reading every 12 hours |
Baud Rate | 57,600 |
Cold Junction Compensation | Automatic |
LED Indicators | Red |
Material | Delrin |
Dimensions | 2.2 in x 2.5 in x 0.9 in (55 mm x 63 mm x 22 mm) |
Operating Environment | -20 °C to +80 °C (-4 °F to + 176 °F), 0 %RH to 95 %RH non-condensing |
Range (PSI) | 0-30 | 0-100 | 0-300 | 0-500 | 0-1000 | 0-5000 | |
Accuracy | 2 %FSR, 0.25 % @ 25 °C Typical | ||||||
Resolution (PSI) | 0.002 | 0.005 | 0.02 | 0.05 | 0.05 | 0.2 |
Thermocouple | Range (°C) | Resolution | Accuracy |
J | -210 to +760 | 0.1 °C | ±.5 °C |
K | -270 to +1370 | 0.1 °C | ±.5 °C |
T | -270 to +400 | 0.1 °C | ±.5 °C |
E | -270 to +980 | 0.1 °C | ±.5 °C |
R | -50 to +1760 | 0.5 °C | ±2 °C |
S | -50 to +1760 | 0.5 °C | ±2 °C |
B | +50 to +1820 | 0.5 °C | ±2 °C |
N | -270 to +1300 | 0.1 °C | ±.5 °C |
- Dry Ice Shipments
- Factory systems
- Laboratory testing
- HVAC
- Environmental studies