We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
Measuring Ranges: 0-30” Hg vacuum to 0-7500 PSIG; compound ranges available on request
Accuracy: ±0.5% or ±1.0% of full scale
Compensated Temp.
Range: -4 to 185°F
Temperature Drift
Zero: < ±0.011%/°F for accuracy = 0.5% < ±0.022%/°F for accuracy = 1.0%
Span: < ±0.016%/°F for accuracy = 0.5% < ±0.011%/°F for accuracy = 1.0%
Stability (annual): < ±0.2% of full scale
Sensor Element: Piezo-resistive ceramic
Operating Temp. Range
Process Medium: -40 to 212°F
Ambient: -40 to 150°F
Storage: -40 to 185°F
Overpressure Ratings
30” Hg to 500 PSIG: 2x Max. range
>500 PSIG: 1.2x Max. range
Process Wetted Parts
Sensing Element: Ceramic
Connection: 304 stainless steel
O-Ring: Buna-N, others available on request
Housing Material: 303 stainless steel
Power Supply: 16-32 VDC
Output: 4-20 mA, 0-5 VDC, 0-10 VDC
Max. Loop Load: (Vsupply-15)/0.02 (for 4-20 mA)
Response Time: <1 ms from 10% to 90% of scale
Electrical
Connection: Hirschmann Plug (DIN 43650 A) with PG 11 cable gland
Electrical
Protection: NEMA 4/IP 65