We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
The Kanomax Tabmaster in an innovative idyllic tool for precise supply and return airflow measurements complete with a myriad of features.
With the addition of the removable handheld micromanometer with Bluetooth wireless capability and using the base meter it is now feasible to take airflow and pressure readings with a pitot tube (airflow range of 0.15 to 40 m/s +/- 3%; Pressure measurements from -2500 to 2500 Pa +/- 0.25%, with high resolution) or the optional velocity matrix (range of 0.15 to 15 m/s with a 3% accuracy).Due to the cross shape of the matrix grid it is now possible to take face velocity readings and average velocity readings at numerous points simultaneously.
The Bluetooth feature has the ability to send data directly to a smartphone or any Android-based device allowing for efficient data sharing.
Its unique design boasts interchangeable hoods allowing for effortless air samples to be taken for any duct size. Conveniently constructed it is light weight, easy to handle and promotes a full color screen that can be titled for optimum viewing angles at any height.
Airflow Measuring Range | 23 to 2500 CFM (40 to 4250 m3/h) |
Accuracy | 3% of measuring +/- 10 m3/h |
Resolution | 1 m3/h |
Airflow Velocity Range | 0.15 to 40 m/s (pitot); |
Temperature Measuring Range | 32 to 122°F (0 to 50°C) |
Accuracy | +/- 1°F (0 to 50°C) |
Resolution | 0.1°C |
Humidity Measuring Range | 0-100% RH |
Accuracy | +/- 3.0 %RH |
Resolution | 0.1 %RH |
Standard Hood Dimensions | 610x610mm |
Optional Hood Dimensions | 610x1220mm, 305x1220mm, |
Datalogging | Up to 8,000 Measurements |
Power Supply | 4 x AA batteries or AC Adapter |
Weight & Dimensions | 7.9 lbs (3.6 kg), Main Body: 3.4" x 7.4" x 1.6" |
Micromanometer Specifications (included with 6715) | ||
Model | 6700 | |
Air Velocity | Ranges
Accuracy Resolution | 0.15 to 40 m/s (with pitot tube) 0.15 to 15 m/s (with Velocity Matrix) +/- 3% of reading +/- 0.05m/s 0.01 m/s (<9.99m/s), 0.12 m/s (>10.0m/s) |
Pressure | Ranges Accuracy Resolution | -2500 to 2500 Pa +/- 0.25% of reading +/- 1 Pa 0.001 Pa |
Temperature | Ranges Accuracy Resolution | -32 to 122°F (0 to 50°C) +/- 1.0°F (0.5°C) 0.1°C |
Relative Humidity | Ranges Accuracy Resolution | 0 to 100 %RH +/- 3.0 %RH 0.1 %RH |
Interface | USB, Bluetooth® | |
Datalogging | Up to 8,000 records | |
Power Supply | AA batteries or AC Adapter |
Includes: Standard hood, carrying case, AA batteries, user manual, communication cable for PC, PC software and calibration certificate
- HVAC testing, adjusting and balancing
- Air volumetric flow measurements through registers, diffusers and grilles
- Direct readout at supply and return airflow
- Air velocity measurement in the duct
- Check filter fouling by measuring differential pressure