We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
Model | PSW | 80-13.5 | |
Rated Output Voltage | V | 80 | |
Rated Output Current | A | 13.5 | |
Rated Output Power | W | 360 | |
Power Ratio | -- | 3 | |
Constant Voltage Mode | PSW | 80-13.5 | |
Line Regulation (*1) | mV | 43 | |
Load Regulation (*2) | mV | 45 | |
Ripple and Noise (*3) | |||
| p-p (*4) | mV | 60 |
| r.m.s (*5) | mV | 7 |
Temperature coefficient | ppm/°C | 100ppm/°C of rated output voltage, after a 30 minute warm-up. | |
Remote sense compensation voltage | V/wire | 0.6 | |
Rise Time (*6) | |||
| Rated Load | ms | 50 |
| No Load | ms | 50 |
Fall Time (*7) | |||
| Rated Load | ms | 50 |
| No Load | ms | 500 |
Transient response time (*8) | ms | 1 | |
Constant Current Mode | PSW | 80-13.5 | |
Line regulation (*1) | mA | 18.5 | |
Load regulation (*9) | mA | 18.5 | |
Ripple and noise | |||
| r.m.s (*5 ) | mA | 27 |
Temperature coefficient | ppm/°C | 200ppm/°C of rated output current, after a 30 minute warm-up. | |
Protection Function | PSW | 80-13.5 | |
Over voltage protection (OVP) | |||
| Setting range | V | 8-88 |
| Setting accuracy |
| ± (2% of rated output voltage) |
Over current protection (OCP) | |||
| Setting range | A | 1.35-14.85 |
| Setting accuracy |
| ± (2% of rated output current) |
Over temperature protection (OTP) | |||
| Operation |
| Turn the output off. |
Low AC input protection (AC-FAIL) | |||
| Operation |
| Turn the output off. |
Power limit (POWER LIMIT) | |||
| Operation |
| Over power limit. |
| Value (fixed) |
| Approx. 105% of rated output power |
Front Panel | PSW | 80-13.5 | |
Display, 4 digits | |||
| Voltage accuracy 0.1% + | mV | 20 |
| Current accuracy 0.1% + | mA | 20 |
Programming and Measurement (Interface) | PSW | 80-13.5 | |
Voltage programming accuracy 0.1% + | mV | 10 | |
Current programming accuracy 0.1% + | mA | 10 | |
Voltage programming resolution | mV | 2 | |
Current programming resolution | mA | 1 | |
Voltage measurement accuracy 0.1% + | mV | 10 | |
Current measurement accuracy 0.1% + | mA | 10 | |
Voltage measurement resolution | mV | 2 | |
Current measurement resolution | mA | 1 | |
Common Specification | |||
Input Characteristics | PSW | 80V | |
Nominal input rating |
| 100Vac to 240Vac, 50Hz to 60Hz, single phase | |
Input voltage range |
| 85Vac ~ 265Vac | |
Input voltage range |
| 47Hz ~ 63Hz | |
Maximum input current | |||
| 100Vac | A | 360W: 5A, 720W: 10A, 1080W: 15A |
| 200Vac | A | 360W: 2.5A, 720W: 5A, 1080W: 7.5A |
Inrush current | A | < 25A for 360W, < 50A for 720W, < 75A for 1080W | |
Maximum input power | VA | 360W: 500VA, 720W: 1000VA, 1080W: 1500VA | |
Power factor | |||
| 100Vac |
| 0.99 |
| 200Vac |
| 0.97 |
Efficiency | |||
| 100Vac | % | 78 |
| 200Vac | % | 80 |
Hold-up time |
| 20ms or greater | |
Analog Programming and Monitoring | PSW | 80V | |
External voltage control output voltage |
| Accuracy and linearity: ±0.5% of rated output voltage. | |
External voltage control output current |
| Accuracy and linearity: ±1% of rated output current. | |
External resistor control output voltage |
| Accuracy and linearity: ±1.5% of rated output voltage. | |
External resistor control output current |
| Accuracy and linearity: ±1.5% of rated output current. | |
Output voltage monitor | |||
| Accuracy | % | ±1 |
Output current monitor | |||
| Accuracy | % | ±1 |
Shutdown control |
| Turns the output off with a LOW (0V to 0.5V) or short-circuit. | |
Output on/off control |
| Possible logic selections: | |
CV/CC/ALM/PWR ON/OUT ON indicator |
| Photocoupler open collector output; Maximum voltage 30V, maximum sink current 8mA. | |
Series and Parallel Capability | PSW | 80V | |
Parallel number | Units | 3 | |
Series Number | Units | 2 | |
Front Panel | |||
Indications |
| GREEN LED's: | |
Buttons |
| Function, OVP/OCP, Set, Test, Lock/Local, PWR DSPL, Output | |
Knobs |
| Voltage, Current | |
USB port |
| Type A USB connector | |
Interface Capabilities | |||
USB |
| TypeA: Host, TypeB: Slave, Speed: 1.1/2.0, USB Class: CDC(Communications Device Class) | |
LAN |
| MAC Address, DNS IP Address, User Password, Gateway IP Address, Instrument IP Address, Subnet Mask | |
GPIB |
| Optional: GUG-001 (GPIB to USB Adapter) | |
Environmental Conditions | |||
Operating temperature |
| 0˚C to 50˚C | |
Storage temperature |
| -25˚C to 70˚C | |
Operating humidity |
| 20% to 85% RH; No condensation | |
Storage humidity |
| 90% RH or less; No condensation | |
Altitude |
| Maximum 2000m | |
General Specifications | |||
Weight (main unit only) | kg | Approx. 3kg for 360W, | |
Dimensions (WxHxD) | mm3 | 360W: 71×124×350mm, | |
Cooling |
| Forced air cooling by internal fan. | |
EMC |
| Complies with the European EMC directive 2004/108 /EC for Class A test and measurement products. | |
Safety |
| Complies with the European Low Voltage Directive 2006 /95/EC and carries the CE-marking. | |
Withstand voltage |
| Between input and chassis: No abnormalities at 1500 Vac for 1 minute. | |
Between input and output: No abnormalities at 3000 Vac for 1 minute. | |||
Between output and chassis: | |||
No abnormalities at 1500 Vdc for 1 minute for 250V, 800V models. | |||
Insulation resistance |
| Between input and chassis: 500 Vdc, 100MΩ or more | |
Between input and output: 500 Vdc, 100MΩ or more | |||
Between output and chassis: | |||
1000Vdc, 100MΩ or more for 800V models. |
Notes
*1: At 85 ~ 132Vac or 170 ~ 265Vac, constant load.
*2: From No-load to Full-load, constant input voltage. Measured at the sensing point in Remote Sense.
*3: Measure with JEITA RC-9131B (1:1) probe
*4: Measurement frequency bandwidth is 10Hz to 20MHz.
*5: Measurement frequency bandwidth is 5Hz to 1MHz.
*6: From 10% to 90% of rated output voltage, with rated resistive load.
*7: From 90% to 10% of rated output voltage, with rated resistive load.
*8: Time for output voltage to recover within 0.1% + 10mV of its rated output for a load change from 50 to 100% of its rated output current.
*9: For load voltage change, equal to the unit voltage rating, constant input voltage.