Key Features:

  • Voltage Rating: 30/80V/160V, Output Power: 360W ~ 1080W
  • Constant Power Output for Multiple Range (V&I) Operation
  • CV/CC Priority; Particularly Suitable for the Battery and LED Industry
  • Adjustable Slew Rate
  • Series and Parallel Operation (2 units in Series / 3 units in Parallel Maximum)
  • High Efficiency and High Power Density
  • 1/6 Rack Mount Size Design (EIA/JIS Standard)
  • Standard Interface: LAN,USB,Analog Control Interface, GPIB-USB Adaptor(Optional)
  • Labview Driver
Product Options:
$2,360.00

Secured and trusted checkout with

The PSW-Series is a single output multi-range programmable switching DC Power Supply covering a power range up to 1080W. This series of products include six models with the combination of 30V,80V and 160V rated voltages and 360W, 720W and 1080W maximum output powers. The multi-range feature allows the flexible and efficient configuration of voltage and current within the rated power range. As the PSW-Series can be connected in series for maximum 2 units or in parallel for maximum 3 units, the capability of connecting multiple PSW units for higher voltage or higher current output provides a broad coverage of applications. With the flexibility of multi-range power utilization and series/parallel connection, the PSW Series significantly reduces the user’s investment for various power supply products to accommodate the projects with different power requirements.

Model

PSW

30-108

Rated Output Voltage

V

30

Rated Output Current

A

108

Rated Output Power

W

1080

Power Ratio

--

3

Constant Voltage Mode

PSW

30-108

Line Regulation (*1)

mV

18

Load Regulation (*2)

mV

20

Ripple and Noise (*3)

 

p-p (*4)

mV

100

 

r.m.s (*5)

mV

14

Temperature coefficient

ppm/°C

100ppm/°C of ra ted output voltage, after a 30 minute warm-up.

Remote sense compensation voltage

V/wire

0.6

Rise Time (*6)

 

Rated Load

ms

50

 

No Load

ms

50

Fall Time (*7)

 

Rated Load

ms

50

 

No Load

ms

500

Transient response time (*8)

ms

1

Constant Current Mode

PSW

30-108

Line regulation (*1)

mA

113

Load regulation (*9)

mA

113

Ripple and noise

 

r.m.s (*5 )

mA

216

Temperature coefficient

ppm/°C

200ppm/°C of rated output current, after a 30 minute warm-up .

Protection Function

PSW

30-108

Over voltage protection (OVP)

 

Setting range

V

3-33

 

Setting accuracy

 

± (2% of rated output voltage)

Over current protection (OCP)

 

Setting range

A

5-118.8

 

Setting accuracy

 

± (2% of rated output current)

Over temperature protection (OTP)

 

Operation

 

Turn the output off.

Low AC input protection (AC-FAIL)

 

Operation

 

Turn the output off.

Power limit (POWER LIMIT)

 

Operation

 

Over power limit.

 

Value (fixed)

 

Approx. 105% of rated output power

Front Panel

PSW

30-108

Display, 4 digits

 

Voltage accuracy 0.1% +

mV

20

 

Current accuracy 0.1% +

mA

100

Programming and Measurement (Interface)

PSW

30-108

Voltage programming accuracy 0.1% +

mV

10

Current programming accuracy 0.1% +

mA

100

Voltage programming resolution

mV

1

Current programming resolution

mA

3

Voltage measurement accuracy 0.1% +

mV

10

Current measurement accuracy 0.1% +

mA

100

Voltage measurement resolution

mV

1

Current measurement resolution

mA

3

Common Specification

Input Characteristics

PSW

30V

Nominal input rating

 

100Vac to 240Vac, 50Hz to 60Hz, single phase

Input voltage range

 

85Vac ~ 265Vac

Input voltage range

 

47Hz ~ 63Hz

Maximum input current

 

100Vac

A

360W: 5A, 720W: 10A, 1080W: 15A

 

200Vac

A

360W: 2.5A, 720W: 5A, 1080W: 7.5A

Inrush current

A

< 25A for 360W, < 50A for 720W, < 75A for 1080W

Maximum input power

VA

360W: 500VA, 720W: 1000VA, 1080W: 1500VA

Power factor

 

100Vac

 

0.99

 

200Vac

 

0.97

Efficiency

 

100Vac

%

77

 

200Vac

%

79

Hold-up time

 

20ms or greater

Analog Programming and Monitoring

PSW

30V

External voltage control output voltage

 

Accuracy and linearity: ±0.5% of rated output voltage.

External voltage control output current

 

Accuracy and linearity: ±1% of rated output current.

External resistor control output voltage

 

Accuracy and linearity: ±1.5% of rated output voltage.

External resistor control output current

 

Accuracy and linearity: ±1.5% of rated output current.

Output voltage monitor

 

Accuracy

%

±1

Output current monitor

 

Accuracy

%

±1

Shutdown control

 

Turns the output off with a LOW (0V to 0.5V) or short-circuit.

Output on/off control

 

Possible logic selections:
Turn the output on using a LOW (0V to 0.5V) or short-circuit, turn the output off using a HIGH (4.5V to 5V) or open-circuit.
Turn the output on using a HIGH (4.5V to 5V) or open-circuit, turn the output off using a LOW (0V to 0.5V) or short-circuit.

CV/CC/ALM/PWR ON/OUT ON indicator

 

Photocoupler open collector output; Maximum voltage 30V, maximum sink current 8mA.

Series and Parallel Capability

PSW

30V

Parallel number

Units

3

Series Number

Units

2

Front Panel

Indications

 

GREEN LED's:
CV, CC, VSR, ISR, DLY, RMT, 20, 40, 60, 80, 100, %W, W, V, A
RED LED's: ALM

Buttons

 

Function, OVP/OCP, Set, Test, Lock/Local, PWR DSPL, Output

Knobs

 

Voltage, Current

USB port

 

Type A USB connector

Interface Capabilities

USB

 

TypeA: Host, TypeB: Slave, Speed: 1.1/2.0, USB Class: CDC(Communications Device Class)

LAN

 

MAC Address, DNS IP Address, User Password, Gateway IP Address, Instrument IP Address, Subnet Mask

GPIB

 

Optional: GUG-001 (GPIB to USB Adapter)

Environmental Conditions

Operating temperature

 

0˚C to 50˚C

Storage temperature

 

-25˚C to 70˚C

Operating humidity

 

20% to 85% RH; No condensation

Storage humidity

 

90% RH or less; No condensation

Altitude

 

Maximum 2000m

General Specifications

Weight (main unit only)

kg

Approx. 3kg for 360W,
Approx. 5.3kg for 720W,
Approx. 7.5kg for 1080W

Dimensions (WxHxD)

mm3 

360W: 71×124×350mm,
720W: 142×124×350mm,
1080W: 214×124×350mm

Cooling

 

Forced air cooling by internal fan.

EMC

 

Complies with the European EMC directive 2004/108 /EC for Class A test and measurement products.

Safety

 

Complies with the European Low Voltage Directive 2006 /95/EC and carries the CE-marking.

Withstand voltage

 

Between input and chassis: No abnormalities at 1500 Vac for 1 minute.

Between input and output: No abnormalities at 3000 Vac for 1 minute.

Between output and chassis:
No abnormalities at 500 Vdc for 1 minute for 30V, 80V, 160V models.

No abnormalities at 1500 Vdc for 1 minute for 250V, 800V models.  

Insulation resistance

 

Between input and chassis: 500 Vdc, 100MΩ or more

Between input and output: 500 Vdc, 100MΩ or more

Between output and chassis:
500 Vdc, 100MΩ or more for 30V, 80V, 160V and 250V models.

1000Vdc, 100MΩ or more for 800V models.  

Notes

*1: At 85 ~ 132Vac or 170 ~ 265Vac, constant load.
*2: From No-load to Full-load, constant input voltage. Measured at the sensing point in Remote Sense.
*3: Measure with JEITA RC-9131B (1:1) probe
*4: Measurement frequency bandwidth is 10Hz to 20MHz.
*5: Measurement frequency bandwidth is 5Hz to 1MHz.
*6: From 10% to 90% of rated output voltage, with rated resistive load.
*7: From 90% to 10% of rated output voltage, with rated resistive load.
*8: Time for output voltage to recover within 0.1% + 10mV of its rated output for a load change from 50 to 100% of its rated output current.
*9: For load voltage change, equal to the unit voltage rating, constant input voltage.

Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account

Products In This Series

As low as

Now $3,506.00

As low as

Now $3,392.00

As low as

Now $1,839.00

As low as

Now $1,724.00