The PEL-3000 series, a single-channel, programmable D.C. electronic load with 0.01mA current resolution and 16A/μs current Slew Rate, is very ideal for testing server power supply and SPS (Switching Power Supply) for commercial and industrial computers. For a heavy-duty device like cloud ecosystem running 24-hour nonstop operations, a stable and high-power power supply, ranging from 350W to 1500W, is required to maintain the normal operation of server, Hub, and the equipment of data storage and internet communications. Owing to the increasing demand of data transmission and large scale data storage of telecommunications systems, the infrastructure of internet communications is in the pace of rapid expansion. This has greatly boosted the market demand of telecommunications equipment powered by power supply of 2000W and above. The flexible power combination of PEL-3000 meets the test requirements of present high-power power supply.
Three Operating Functions
Model | PEL-3021 | PEL-3041 | PEL-3111 | PEL-3211 | |||||||
Voltage | 1.5V~150V | 1.5V~150V | 1.5V~150V | 1.5V~150V | |||||||
Current | 35A | 70A | 210A | 420A | |||||||
Power | 175W | 350W | 1050W | 2100W | |||||||
Constant Current Mode | |||||||||||
Operating Range | 0~35A | 0~3.5A | 0~0.35A | 0~70A | 0~7A | 0~0.7A | 0~210A | 0~21A | 0~2.1A | 420A | |
Accuracy of Setting | H,M,L | ±(0.2 % of set + 0.1 % of f.s*1) + Vin*2/500 kΩ | ±(1.2% of set +1.1% of f.s) | ||||||||
Accuracy of Setting(Parallel) | H,M,L | ±(1.2 % of set + 1.1 % of f.s*3) | |||||||||
Resolution | 1mA | 0.1mA | 0.01mA | 2mA | 0.2mA | 0.02mA | 10mA | 1mA | 0.1mA | N/A | |
Constant Resistance Mode | |||||||||||
Operating Range | H | 23.33365S~400uS (42.857mΩ~2.5kΩ) | 46.6672S~800uS (21.428mΩ~1.25KΩ) | 140.0016S~2.4mS (7.1427mΩ~416.6667Ω) | 28.0002s~484.8us (35.7135mΩ~2.08334Ω) | ||||||
M | 2.33336S~40uS (428.566mΩ~25kΩ) | 4.6667S~80uS (214.28mΩ~12.5kΩ) | 14.0001S~242.4uS (71.427mΩ~4.16667Ω) | ||||||||
L | 0.233336S~4uS (4.28566Ω~250kΩ) | 0.46667S~8uS (2.1428Ω~125kΩ) | 1.40001S~24.24uS (714.27mΩ~41.6667kΩ) | ||||||||
Accuracy of Setting | H,M,L | ±(0.5 % of set*4 + 0.5 % of f.s*1) + Vin*3/500kΩ | ±(1.2% of set +1.1% of f.s) | ||||||||
Resolution | 400uS | 40uS | 4uS | 800uS | 80uS | 8uS | 2.4mS | 240uS | 24uS | N/A | |
Constant Voltage Mode | |||||||||||
Operating Range | H | 1.5V~150V | 1.5V~150V | 1.5V~150V | 1.5V~150V | ||||||
L | 1.5V~15V | 1.5V~15V | 1.5V~15V | 1.5V~15V | |||||||
Accuracy of Setting | H,L | ±(0.1 % of set + 0.1 % of f.s.) | ±(0.1 % of set + 0.1 % of f.s.) | ±(0.1 % of set + 0.1 % of f.s.) | N/A | ||||||
Resolution | H,L | 10mV / 1mV | 10mV / 1mV | 10mV / 1mV | N/A | ||||||
Constant Power Mode | |||||||||||
Operating Range | H | 17.5W~175W | 35W~350W | 105W~1050W | 210W~2100W | ||||||
M | 1.75W~17.5W | 3.5W~35W | 10.5W~105W | 21W~210W | |||||||
L | 0.175W~1.75W | 0.35W~3.5W | 1.05W~10.5W | 2.1W~21W | |||||||
Accuracy of Setting | H,M,L | ±(0.6 % of set*5 + 1.4 % of f.s*6) | N/A | ||||||||
Resolution | 10mW | 1mW | 0.1mW | 10mW | 1mW | 0.1mW | 100mW | 10mW | 1mW | N/A | |
PARALLEL Mode | |||||||||||
Capacity | 875W | 1750W | 5250W | PEL-3111 with 4 booster units: Max 9.45kW | |||||||
Slew Rate | |||||||||||
Setting Range (CC mode) | H | 2.5mA/us~2.5A/us | 5mA/us~5A/us | 16mA/us~16A/us | 16mA/us~16A/us | ||||||
M | 250uA/us~250mA/us | 500uA/us~500mA/us | 1.6mA/us~1.6A/us | 1.6mA/us~1.6A/us | |||||||
L | 25uA/us~25mA/us | 50uA/us~50mA/us | 160uA/us~160mA/us | N/A | |||||||
Resolution | 0.1uA ~ 1mA | 0.2uA ~ 2mA | 0.6uA ~ 6mA | N/A | |||||||
Setting Range (CR mode) | H | 250uA/us~250mA/us | 500uA/us~500mA/us | 1.6mA/us~1.6A/us | 1.6mA/us~1.6A/us | ||||||
M | 25uA/us~25mA/us | 50uA/us~50mA/us | 160uA/us~160mA/us | 160uA/us~160mA/us | |||||||
L | 2.5uA/us~2.5mA/us | 5uA/us~5mA/us | 16uA/us~16mA/us | N/A | |||||||
Resolution | 0.1uA ~ 1mA | 0.2uA ~ 2mA | 0.6uA ~ 6mA | N/A | |||||||
Accuracy of Setting | H,M,L | ±(10 % of set*7+ 5us) | N/A | ||||||||
METER | |||||||||||
Voltmeter | Accuracy | ±(0.1 % of rdg + 0.1 % of f.s.) | N/A | ||||||||
Ammeter | Accuracy | ±(0.2 % of rdg + 0.3 % of f.s.) | N/A | ||||||||
Ammeter (Parallel Operation) | Accuracy | ±(1.2 % of rdg + 1.1 % of f.s.) | N/A | ||||||||
DYNAMIC MODE | |||||||||||
Operation mode | CC / CR | ||||||||||
T1 & T2 | 0.025ms ~ 10ms / Res : 1us ; 1ms ~ 30s / Res : 1ms | ||||||||||
Accuracy | 1us / 1ms ±100ppm | ||||||||||
Slew Rate (CC Mode) | H | 2.5mA/us~2.5A/us | 5mA/us~5A/us | 16mA/us~16A/us | 16mA/us~16A/us | ||||||
M | 250uA/us~250mA/us | 500uA/us~500mA/us | 1.6mA/us~1.6A/us | 1.6mA/us~1.6A/us | |||||||
L | 25uA/us~25mA/us | 50uA/us~50mA/us | 160uA/us~160mA/us | N/A | |||||||
Slew Rate (CR Mode) | H | N/A | |||||||||
M | |||||||||||
L | |||||||||||
Current Accuracy | ±0.4%F.S | ±0.4%F.S | ±0.4%F.S | ±(1.2% of set +1.1% of f.s) | |||||||
Protection Function | |||||||||||
Overvoltage (OVP) | Adjustable ; Turns off the load at 110% of the rated voltage | N/A | |||||||||
Overcurrent (OCP) | 0.03A ~ 38.5A (Adjustable) | 0.06A ~ 77A (Adjustable) | 0.2A ~ 231A (Adjustable) | ||||||||
Overpower (OPP) | 0.1W ~ 192.5W (Adjustable) | 0.3W ~ 385W (Adjustable) | 1W ~ 1155W (Adjustable) | ||||||||
Overheat (OHP) | Turns off the load when the heat sink temperature reaches 95 °C | ||||||||||
Undervoltage (UVP) | Adjustable : Turns off the load when detected. Can be set in the range of 0 V to 150 V or Off. | ||||||||||
Reverse connection (REV) | By diode. Turns off the load when an alarm occurs. | ||||||||||
General Specifications | |||||||||||
Power Source | AC100V ~ 230V±10% ; 50Hz / 60Hz ± 2Hz | ||||||||||
Interface | USB/RS232C/Analog Control (Standard) ; GPIB(Option) | ||||||||||
Weight | Approx. 6kg | 7kg | 17kg | 23kg | |||||||
DIMENSIONS & WEIGHT | 214.5(W)x124(H)x400(D)mm. | 214.5(W)x124(H)x400(D)mm | 429.5(W)x128(H)x400(D)mm | 427.7(W)x128(H)x592.5(D)mm |
*1 Full scale of H rangerated current.
*2 Vin: input terminal voltage of electric load.
*3 M range applies to the full scale of H range
*4 Set = Vin / Rset
*5 It is not applied for the conditon of the parallel operation
*6 M range applies to the full scale of H range
*7 Time to reach from 10% ~ 90% when the current is varied from 2% ~ 100% (20% ~ 100% in M range) of the rated current.