We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
GW Instek is offering their LCR-8205 5MHz High-Precision LCR Meter as part of their new LCR-8200 series of high frequency meters. The LCR-8205 is equipped with a test frequency of up to 5 MHz and features a 0.08% high measurement accuracy. Measurement results can be shown numerically or graphically on the 7” color display, allowing for users to best interpret the characteristics of the DUT. The unit is constructed with a full range of standard interfaces like USB device, RS-232C, handler and GPIB, all of which allow for control of the instrument via the most familiar interface. The USB storage function when operating in the graphics mode, saves measured characteristic curves and values of the DUT for later analysis. The list of efficient features and functions make the LCR-8205 essential for test requirements of passive components in R&D, production and engineering.
MODEL | LCR-8230 | LCR-8220 | LCR-8210 | LCR-8205 | LCR-8201 |
TEST FREQUENCY | |||||
DC, 10Hz~30MHz; 6 Digits, ±0.0007% | DC, 10Hz~20MHz; 6 Digits, ±0.0007% | DC, 10Hz~10MHz; 6 Digits, ±0.0007% | DC, 10Hz~5MHz; 6 Digits, ±0.0007% | DC,10Hz~1MHz; 6 Digits, ±0.0007% | |
OUTPUT IMPEDANCE | |||||
25Ω / 100Ω SELECTABLE | |||||
BASIC ACCURACY | |||||
±0.08% | |||||
TEST SPEED | |||||
MAX: 25ms(>10kHz), FAST: 50ms(>20Hz), MEDIUM: 100ms SLOW: 300ms, SLOW2: 600ms | |||||
TEST SIGNAL LEVEL | |||||
AC Voltage: | 10mV ~ 2Vrms (FREQ. ≦1MHz), 10mV ~ 1Vrms (FREQ. > 1MHz or FREQ. ≦1MHz and RO=25Ω) | ||||
AC Current: | 100μA ~ 20mArms (RO=100Ω), 200μA ~ 40mArms (RO=25Ω) | ||||
DCR Voltage: | 1Vdc (40mA max.) | ||||
MEASUREMENT PARAMETERS | |||||
Maximum four parameterscan be measured and displayed at the same time Impedance (Z), Inductance (Ls / Lp), Capacitance (Cs / Cp), AC Resistance (Rs / Rp), Quality Factor (Q), Dissipation Factor (D), Admittance (Y), Conductance (G), Reactance (X), Phase Angle (θd / θr), Susceptance (B), DC Resistance (Rdc) | |||||
LIST MEASUREMENT | |||||
Listed Steps: | 15 | ||||
Listed Parameters: | Freq/Vac/Iac/DC Bias/Comp/BIN | ||||
Trigger: | AUTO, REPEAT, SINGLE | ||||
SWEEP MEASUREMENT | |||||
Swept Graphical: | Two of measurement parameters | ||||
Swept Parameters: | Freq/Vac/Iac, Keep Trace | ||||
OTHER FUNCTIONS | |||||
Auto Level Control (ALC): | Standard | ||||
DC Bias: | 0~±12V | ||||
Handler: | PASS, FAIL and OK, NG or BIN 1-9 | ||||
OTHER FEATURES | |||||
Correction: | Open/Short/HF Load/Load | ||||
V/I Monitor: | Vac, Iac, Vdc, Idc | ||||
Comparator: | Value, Δ, Δ% | ||||
Buzzer: | OFF, Pass, Fail | ||||
Average: | 1 to 64 | ||||
GENERAL | |||||
DISPLAY | 7" LCD color display (800x480) | ||||
INTERFACE | USB/GPIB/LAN/RS-232/Handler/USB Host/TRIGGER Input | ||||
POWER SOURCE | AC 100V~240V, 50/60Hz; Consumption: 65VA (max.) | ||||
DIMENSIONS & WEIGHT | 346 (W) X 145 (H) X 335 (D)mm; Approx. 3.3kg |