GW Instek GPT-9513 5KV AC Multi-Channel Hipot Tester

SKU
GPT-9513
Manufacturer:
GW Instek
GW Instek

Key Features:

  • 5KV AC Test Capacity
  • 3 in 1 Tester : AC, DC, IR
  • Built-in 8 channel Scanner
  • 480 x 272 Color TFT LCD
  • Test parameter Export / Import through USB host
  • Statistics (counter) function
  • Insulation resistance measurement up to 10GΩ
  • Open/Short Check (OSC)
  • ARC detection
  • Multi-language: Traditional / Simplified Chinese、English
  • Interface: RS-232C and USB host/device
Product Options:
$3,155.00

Secured and trusted checkout with

The GW Instek GPT-9513 is a three-in-one multi-channel tester that can be set to H, L or X of the 8 channels according to the test requirements, making the GPT-9513 suitable for winding components such as transformers to perform mutual testing of multiple points of single components.

 

Includes:

• Quick Start Guide x1, CD x1(completed user manual)
Power cord x1
Test lead GHT-115 x1, GHT-116B x1, GHT-116R x8

AC Withstanding

Output-Voltage Range

0.050kV~5.000kV

Output-Voltage Resolution

1V

Output-Voltage Accuracy

± (1% of setting + 5V) [no load]

Maximum Rated Load

150 VA (5kV/30mA)

Maximum Rated Current

30mA

0.001mA ~ 10mA (0.05kV≦ V ≦0.5kV)

0.001mA ~ 30mA (0.5kV< V ≦5kV)

Output-Voltage Waveform

Sine wave

Voltage Regulation

± (1% + 5V) [maximum rated load → no load]

Output-Voltage Frequency

50 Hz / 60 Hz selectable

Voltmeter Accuracy

± (1% of reading + 5V)

Current Measurement Range

0.001mA ~ 30.00mA

Current Best Resolution

1μA (0.001mA ~ 9.999mA)

10μA (10.00mA ~ 30.00mA)

Current Measurement Accuracy

±(1.5% of reading + 30μA)

Current Offset

80μA maximum

ARC Detect

Yes

RAMP TIME (Rise T ime)

0.1s~999.9s

FALL Time

OFF~999.9s

WAIT T ime

OFF~999.9s

TIMER (Test Time)

CONT2, 0.3s~999.9s

TIMER Accuracy

± (100ppm + 20ms)

GND

ON/OFF

DC Withstanding

Output-Voltage Range

0.050kV~6.000kV

Output-Voltage Resolution

1V

Output-Voltage Accuracy

± (1% of setting + 5V) [no load]

Maximum Rated Load

50W (5kV/10mA)

Maximum Rated Current

10mA

0.001mA ~ 2mA (0.05kV≦ V ≦0.5kV)

0.001mA ~ 10mA (0.5kV< V ≦6kV)

Voltmeter Accuracy

± (1% of reading + 5V)

Voltage Regulation

± (1% + 5V) [maximum rated load → no load]

Current Measurement Range

0.001mA ~ 10.00mA

Current Best Resolution

0.1μA (0.1μA ~ 999.9μA)

1μA (1μA ~ 9.999mA)

10μA (10.00mA)

Current Measurement Accuracy

±(1% of reading + 1μA) when I Reading < 1mA

±(1% of reading + 10μA) when I Reading  ≧1mA

Current Offset

5μA maximum

ARC Detect

Yes

RAMP TIME (Rise Time)

0.1s~999.9s

FALL Time

OFF~999.9s

WAIT Time

OFF~999.9s

TIMER (Test Time)

CONT2, 0.3s~999.9s

TIMER Accuracy

± (100ppm + 20ms)

GND

ON/OFF

Insulation Resistance

Output Voltage

50V~1000V dc

Output-Voltage Resolution

1V

Output-Voltage Accuracy

± (1% of setting + 5V) [no load]

Resistance Measurement

0.1MΩ~ 10GΩ

Test Voltage

Measurement Range / Accuracy

50V≦ V<500V

0.1MΩ~1MΩ:±(5% of reading + 3 count)

1 MΩ~50MΩ:±(5% of reading + 1 count)

51MΩ~2GΩ:±(10% of reading + 1 count)

500V≦ V  ≦1000V

0.1MΩ~1MΩ:±(5% of reading + 3 count)

1 MΩ~500MΩ:±(5% of reading + 1 count)

501MΩ~10GΩ:±(10% of reading + 1 count)

Voltage Regulation

± (1% + 5V) [maximum rated load → no load]

Voltmeter Accuracy

± (1% of reading + 5V)

Short-Circuit Current

10mA max.

Output Impedance

2kΩ

RAMP TIME (Rise T ime)

0.1s~999.9s

FALL Time

OFF~999.9s

WAIT TIME

OFF~999.9s

TIMER (Test Time)*

0.3s~999.9s

TIMER Accuracy

± (100ppm + 20ms)

GND

ON/OFF

Continuity Test

Output-Current

100mA dc

Ohmmeter Measurement Accuracy

1W ± 0.2W, ON/OFF

Interface

Signal I/O

Standard

RS-232C

Standard

USB (device)

Standard

USB (host)

Standard (for parameter / LCD hardcopy)

Rear Output

Scanner

DISPLAY

 

4.3” color LCD

POWER SOURCE

 

AC 100V~240V ± 10%, 50Hz/60Hz

DIMENSION & WEIGHT

 

320(W) x 120(H) x 435(D) mm; Approx. 11kg

Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account

Products In This Series

As low as

Now $2,522.00