We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
The GW Instek GPT-15004 is the first safety analyzer in the world to comply with IEC 61010-2-034. The GPT-15004 features AC/DC withstanding voltage test, insulation resistance test, AC ground bond test and continuity test.
Includes:
• Quick Start Guide x1, CD x1(completed user manual)
• Power cord x1, Interlock key x1
• Remote terminal Cable GHT-119 x1
• Test lead GHT-115 x1, GTL-215 x1
AC WITHSTANDING | |
Output-Voltage Range | 0.050kV~5.000kV |
Output-Voltage Resolution | 1V |
Output-Voltage Accuracy | ± (1% of setting + 5V) [no load] |
Maximum Rated Load | 500 VA (5kV/100mA) |
Maximum Rated Current | 100mA (0.5kV< V ≦5kV) 10mA (0.05kV≦ V ≦0.5kV) |
Output-Voltage Waveform | Sine wave |
Output-Voltage Frequency | 50 Hz / 60 Hz selectable |
Voltage Regulation | ± (1% + 5V) [maximum rated load → no load] |
Voltmeter Accuracy | ± (1% of reading + 5V) |
Current Measurement Range | 1μA~100.0mA |
Current Best Resolution | 1μA / 10μA / 100μA |
Current Measurement Accuracy | ±(1.5% of reading + 30μA) |
Current Offset | 60μA Maximum |
Window Comparator Method | Yes |
ARC Detect | Yes |
RAMP UP (Rise T ime) | 0.1s~999.9s |
RAMP DOWN (Fall Time) | 0.0s~999.9s |
TIMER (Test Time)* | OFF, 0.3s~999.9s | |
TIMER Accuracy | ±(100ppm + 20ms) | |
WAIT TIME | 0.0s~999.9s | |
GND | ON/OFF | |
DC WITHSTANDING | ||
Output-Voltage Range | 0.050kV~6.000kV | |
Output-Voltage Resolution | 1V | |
Output-Voltage Accuracy | ± (1% of setting + 5V) [no load] | |
Maximum Rated Load | 100W (5kV/20mA) | |
Maximum Rated Current | 20mA (0.5kV< V ≦6kV) 2mA (0.05kV≦ V ≦0.5kV) | |
Voltage Regulation | ± (1% + 5V) [maximum rated load → no load] | |
Voltmeter Accuracy | ± (1% of reading + 5V) | |
Current Measurement Range | 1μA~20.00mA | |
Current Best Resolution | 0.1μA /1μA /10μA | |
Current Measurement Accuracy | ±(1.5% of reading + 3μA) when I Reading < 1mA ±(1.5% of reading + 30μA) when I Reading ≧1mA | |
Current Offset | 5μA Maximum | |
Window Comparator Method | Yes | |
ARC Detect | Yes | |
RAMP UP (Rise T ime) | 0.1s~999.9s | |
RAMP DOWN (Fall Time) | 0.0s~999.9s | |
TIMER (Test Time)* | OFF, 0.3s~999.9s | |
TIMER Accuracy | ±(100ppm + 20ms) | |
WAIT TIME | 0.0s~999.9s | |
GND | ON/OFF | |
INSULATION RESISTANCE | ||
Output Voltage | 50V~1200V dc | |
Output-Voltage Resolution | 50V | |
Output-Voltage Accuracy | ± (1% of setting + 5V) [no load] | |
Resistance Measurement |
| |
Test Voltage | Display Range | Measurement Range / Accuracy |
50V≦V≦100V | 0.1MΩ~ 10.00GΩ | 0.1MΩ~1MΩ:±(5% of reading + 3 count) 1 MΩ~50MΩ:±(5% of reading + 1 count) 51MΩ~2GΩ:±(10% of reading + 1 count) |
150V≦V≦450V | 0.1MΩ~ 20.00GΩ | |
500V≦V≦1200V | 0.1MΩ~ 50.00GΩ | 0.1MΩ~1MΩ:±(5% of reading + 3 count) 1 MΩ~500MΩ:±(5% of reading + 1 count) 501MΩ~9.999GΩ:±(10% of reading + 1 count) 10GΩ~50GΩ:±(20% of reading + 1 count)* |
Voltage Regulation | ± (1% + 5V) [maximum rated load → no load] | |
Voltmeter Accuracy | ± (1% of reading + 5V) | |
Short-Circuit Current | 10mA max. | |
Output Impedance | 2kΩ | |
Window Comparator Method | Yes | |
RAMP UP (Rise T ime) | 0.1s~999.9s | |
RAMP DOWN (Fall Time) | 0.0s~999.9s | |
TIMER (Test Time)* | OFF, 0.3s~999.9s | |
TIMER Accuracy | ±(100ppm + 20ms) | |
WAIT TIME | 0.0s~999.9s | |
GND | ON/OFF | |
Ground Bond | ||
Output-Current | 03.00A~32.00A ac | |
Output-Current Resolution | 0.01A | |
Output-Current Accuracy | 3A≦ I≦ 8A:±(1% of reading + 0.2A) 8A<I≦ 32A:±(1% of reading + 0.05A) | |
Test-Voltage | 8Vac max (open circuit) |
Test-Voltage Frequency | 50Hz/60Hz selectable |
Ohmmeter Measurement Range | 1mW~ 650mW |
Ohmmeter Measurement Resolution | 0.1mW |
Ohmmeter Measurement Accuracy | ±(1% of reading + 2 mW) |
Window Comparator Method | Yes |
TIMER (Test Time) | 0.3s~999.9s |
TIMER Accuracy | ±(100ppm + 20ms) |
Test Method | Four Terminal |
GND | ON/OFF |
Continuity Test | |
Output-Current | 100mA dc (fixed) |
Ohmmeter Measurement Range | 0.10W~ 70.00W |
Ohmmeter Measurement Resolution | 0.01W |
Ohmmeter Measurement Accuracy | ±(10% of reading + 2 W) |
Window Comparator Method | Yes |
TIMER (Test Time)* | 0.3s~999.9s |
TIMER Accuracy | ±(100ppm + 20ms) |
MEMORY | |
Single Step Memory | MANU:100 blocks |
Automatic Testing Memory | AUTO:100 blocks, manu per auto:10 |
INTERFACE | |
REMOTE (Front) terminal | Standard |
USB host (Front) | Standard |
Rear Output | Standard |
RS-232C | Standard |
USB device | Standard |
Signal I/O | Standard |
GPIB | Option |
LAN | Option |
DISPLAY | |
| 7” color LCD |
POWER SOURCE | |
| AC 100V~240V ± 10%, 50Hz/60Hz |
DIMENSION & WEIGHT | |
GPT-15001/15002/15003 GPT-15004 | 380(W) x 148(H) x 492(D) mm; Approx. 17kg 380(W) x 148(H) x 546(D) mm; Approx. 21kg |
* When Ground Mode is “ON”, the measurement range is 30GΩ max. and adding 10% error for accuracy.