GW Instek’s GPT-12002 5KVac – 6KVdc AC/DC Electrical Safety Analyzer from GW Instek is the first safety analyzer in the world to meet IEC 61010-2-034 (Safety requirement for electrical requirement for measurement, control and laboratory use – specific requirements for measurement equipment for insulation resistance and test equipment for electric strength), which specifies that the requirements of the software and hardware interfaces must be followed while designing high voltage and insulation resistance test and measurement instruments so as to guarantee that users are provided with essential protection and warning while using the instrument.
AC WITHSTANDING | ||
Output-Voltage Range | 0.050kV~5.000kV | |
Output-Voltage Resolution | 1V | |
Output-Voltage Accuracy | ± (1% of setting + 5V) [no load] | |
Maximum Rated Load | 200 VA (5kV/40mA) | |
Maximum Rated Current | 40mA (0.5kV< V ≦5kV) 10mA (0.05kV≦V ≦0.5kV) | |
Output-Voltage Waveform | Sine wave | |
Output-Voltage Frequency | 50 Hz / 60 Hz selectable | |
Voltage Regulation | ± (1% +5V) [maximum ratedload → no load] | |
Voltmeter Accuracy | ± (1% of reading +5V) | |
Current Measurement Range | 1μA~40.00mA | |
Current Best Resolution | 1μA / 10μA | |
Current Measurement Accuracy | ± (1.5% of reading + 30μA) | |
Window Comparator Method | Yes | |
ARC Detect | Yes | |
RAMP UP (RiseTime) | 0.1s~999.9s | |
RAMP DOWN(Fall Time) | 0.0s~999.9s | |
TIMER (Test Time) | OFF, 0.3s~999.9s | |
WAIT TIME | 0.0s~999.9s | |
GND | ON/OFF | |
DC WITHSTANDING | ||
Output-Voltage Range | 0.050kV~6.000kV | |
Output-Voltage Resolution | 1V | |
Output-Voltage Accuracy | ± (1% of setting + 5V) [no load] | |
Maximum Rated Load | 50W (5kV/10mA) | |
Maximum Rated Current | 10mA (0.5kV< V ≦6kV) 2mA (0.05kV≦V ≦0.5kV) | |
Voltage Regulation | ± (1% +5V) [maximum rated load → no load] | |
Voltmeter Accuracy | ± (1% of reading + 5V) | |
Current Measurement Range | 1μA~10.00mA | |
Current Best Resolution | 0.1μA /1μA /10μA | |
Current Measurement Accuracy | ± (1.5% of reading + 3μA) when I Reading < 1mA ± (1.5% of reading + 30μA) when I Reading ≧1mA | |
Window Comparator Method | Yes | |
ARC Detect | Yes | |
RAMP UP (Rise Time) | 0.1s~999.9s | |
RAMP DOWN (Fall Time) | 0.0s~999.9s | |
TIMER (Test Time) | OFF, 0.3s~999.9s | |
WAIT TIME | 0.0s~999.9s | |
GND | ON/OFF | |
INSULATION RESISTANCE | ||
Output Voltage | 50V~1200V dc | |
Output-Voltage Resolution | 50V | |
Output-Voltage Accuracy | ± (1% of setting + 5V) [no load] | |
Resistance Measurement | ||
Test Voltage | Display Range | Measurement Range / Accuracy |
50V≦V≦100V | 0.1MΩ~10.00GΩ | 0.1MΩ~1MΩ:± (5% of reading + 3 count) 1 MΩ~50MΩ:± (5% of reading + 1 count) 51MΩ~2GΩ:± (10% of reading + 1 count) |
150V≦V≦450V | 0.1MΩ~ 20.00GΩ | |
500V≦V≦1200V | 0.1MΩ~ 50.00GΩ | 0.1MΩ~1MΩ:± (5% of reading + 3 count) 1 MΩ~500MΩ:± (5% of reading + 1count) 501MΩ~9.999GΩ:± (10% of reading + 1count) 10.00GΩ~50.00GΩ:± (20% of reading + 1count)* |
Voltage Regulation | ± (1% +5V) [maximum rated load → no load] | |
Voltmeter Accuracy | ± (1% of reading + 5V) | |
Short-Circuit Current | 10mA max. | |
Output Impedance | 2kΩ | |
Window Comparator Method | Yes | |
RAMP UP (Rise Time) | 0.1s~999.9s | |
RAMP DOWN (Fall Time) | 0.0s~999.9s | |
TIMER (Test Time) | OFF, 0.3s~999.9s | |
WAIT TIME | 0.0s~999.9s | |
GND | ON/OFF | |
Ground Bond | ||
Output-Current | 03.00A~32.00A ac | |
Output-Current Resolution | 0.01A | |
Output-Current Accuracy | 3A≦I≦8A:± (1% of reading + 0.2A) 8A<I≦32A:± (1% of reading + 0.05A) | |
Test-Voltage | 8Vac max (open circuit) | |
Test-Voltage Frequency | 50Hz/60Hz selectable | |
Ohmmeter Measurement Range | 1mΩ~ 650mΩ | |
Ohmmeter Measurement Resolution | 0.1mΩ | |
Ohmmeter Measurement Accuracy | ±(1% of reading + 2 mΩ) | |
Window Comparator Method | Yes | |
TIMER (Test Time) | 0.3s~999.9s | |
Test Method | Four Terminal | |
GND | ON/OFF | |
Continuity Test | ||
Output-Current | 100mA dc (fixed) | |
Ohmmeter Measurement Range | 0.10Ω~ 70.00Ω | |
Ohmmeter Measurement Resolution | 0.01Ω | |
Ohmmeter Measurement Accuracy | ± (10% of reading + 2Ω) | |
Window Comparator Method | Yes | |
TIMER (Test Time) | 0.3s~999.9s | |
MEMORY | ||
Single Step Memory | MANU:100 blocks | |
Automatic Testing Memory | AUTO:100 blocks, manu per auto:10 | |
INTERFACE | ||
Front panel | REMOTE terminal, USB host | |
Rear panel | Rear Output, RS-232C, USB device, Signal I/O, GPIB (Optional) | |
DISPLAY | ||
7” color LCD | ||
POWER SOURCE | ||
AC 100V~240V ± 10%, 50Hz/60Hz; Consumption: 400VA | ||
DIMENSION & WEIGHT | ||
380(W) x 148(H) x 454(D) mm; Approx. 15kg |