We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
Part of the GPE-X323 DC power supply series, GW Instek’s GPE-2323 has all the functions and capabilities of the GPE-1326, but is configured with 2 independent output channels and offers a few more features.
The GPE-2323 is equipped with an automatic tracking series and parallel connection function. This enables the unit to output 32V/6A (parallel connection) and 64V/3A (series connection).
Click here to view the single channel GPE-1326.
Note: Channels 1 and 2 operate the series and parallel connection functions.
Digital Panel Control | Tracking Series / Parallel Operational |
Remote Control (Remote I/O) for Output On / Off Function |
GPE-4323 | GPE-3323 | GPE-2323 | GPE-1326 | |||||||
Output Mode | ||||||||||
Number of Channel | CH1 | CH2 | CH3 | CH4 | CH1 | CH2 | CH3 | CH1 | CH2 | CH1 |
Voltage | 0~32V | 0~32V | 0~5V | 0~15V | 0~32V | 0~32V | 5.0V | 0~32V | 0~32V | 0~32V |
Current | 0~3A | 0~3A | 0~1A | 0~1A | 0~3A | 0~3A | 5A | 0~3A | 0~3A | 0~6A |
Tracking Series Voltage | 0~64V | ---- | 0~64V | ---- | 0~64V | ---- | ||||
Tracking Parallel Current | 0~6A | 0~6A | 0~6A | |||||||
Constant Voltage Operation | ||||||||||
Line Regulation | ≦0.01%+3mV | |||||||||
Load Regulation | ≦0.01%+3mV(rating current ≦3A) | |||||||||
| ≦0.02%+5mV(rating current >3A) | |||||||||
Ripple & Noise | ≦1mVrms(5Hz~1MHz) | |||||||||
Recovery Time | ≦100μs(50% Load Change, minimum load 0.5A) | |||||||||
Constant Current Operation | ||||||||||
Line Regulation | ≦0.2%+3mA | |||||||||
Load Regulation | ≦0.2%+3mA | |||||||||
Ripple & Noise | ≦3mArms | |||||||||
Tracking Operation(CH1,CH2) | ||||||||||
Tracking Error | ≦0.1%+10mV of Master(0~32V) No Load , with Load add load regulation≦100mV) | |||||||||
Parallel Regulation | Line: ≦0.01%+3mV | |||||||||
Load:≦0.01%+3mV(rating current≦3A) | ||||||||||
≦0.02%+5mV(rating current>3A) | ||||||||||
Series Regulation | Line: ≦0.01%+5mV | |||||||||
Ripple & Noise | Load:≦100mV | |||||||||
CH3 Operation for (GPE-3323) | ||||||||||
Output Voltage | 5.0V, ±5% | |||||||||
Output Current | 5A | |||||||||
Line Regulation | ≦3mV | |||||||||
Load Regulation | ≦5mV | |||||||||
Ripple & Noise | 1mVrms(5Hz~1MHz) | |||||||||
Meter | ||||||||||
Voltage Resolution | 100mV(*1) | |||||||||
Current Resolution | 10mA(*1) | |||||||||
Setting Accuracy | Voltage±(0.1% of reading +30mV) | |||||||||
Current±(0.3% of reading +6mA) | ||||||||||
Readback Accuracy | Voltage±(0.1% of reading +30mV) | |||||||||
Current±(0.3% of reading +6mA) | ||||||||||
Insulation | ||||||||||
Chassis and Terminal | 20MΩ or above (DC 500V) | |||||||||
Chassis and AC Cord | 30MΩ or above (DC 500V) | |||||||||
Environment Condition | ||||||||||
Operation Temp | 0~40℃ | |||||||||
Storage Temp | -10~70℃ | |||||||||
Operating Humidity | ≦80% RH | |||||||||
Storage Humidity | ≦70% RH | |||||||||
Other | ||||||||||
Power Source | AC100V/120V/220V±10%; 230V(+10%~-6%); 50/60Hz | |||||||||
Dimensions & Weight | 210(W)x 155(H) x 306(D) mm ; Approx. 7kg |
(*1): For a higher resolution (10mV/ 1mA), please follow the setting procedure of the user manual on p35.
When using a higher resolution, the current or voltage adjustment may be limited by the knob sensibility.
- Laboratories and Educational Facilities
- Product Testing and Quality Assurance
- Service Operation and Post-Sales Support
- Product Development and Debugging