We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
GW Instek’s ASR-250 is a 500VA AC+DC power source aiming for system integration or desktop applications, providing both rated power output for AC output and rated power output for DC output. Nine ASR-2000 output modes are available, including 1) AC power output mode (AC-INT Mode), 2) DC power output mode (DC-INT Mode), 3) AC/DC power output mode (AC+DC-INT Mode), 4) External AC signal source mode (AC-EXT Mode), 5) External AC/DC signal source mode (AC+DC-EXT Mode), 6) External AC signal superposition mode (AC-ADD Mode), 7) External AC/DC signal superposition mode (AC+DC-ADD Mode), 8) External AC signal synchronization mode (AC-SYNC Mode), 9) External AC/DC signal synchronization mode (AC+DC-SYNC Mode).
Users are suited with waveform output capabilities to satisfy the test requirements of different electronic component development, automotive electrical devices and home appliance, including 1) Sequence mode generates waveform fallings, surges, sags, changes and other abnormal power line conditions; 2) Arbitrary waveform function allows users to store/upload user-defined waveforms; and 3) Simulate mode simulates power outage, voltage rise, voltage fall, and frequency variations. When the ASR-2000 series power source outputs, it can also measure Vrms, Vavg, Vpeak, Irms, Iavg, Ipeak, IpkH, P, S, Q, PF, CF, 40th-order Voltage Harmonic and Current Harmonic. More still, the Remote sense function provides precision voltage output. The Customized Phase Angle for Output On/Off function can set the starting angle and ending angle of the voltage output according to the test requirements. V-Limit, Ipeak-Limit, F-Limit, OVP, OCP, OPP function settings can protect the DUT during the measurement process. In addition to OTP, OCP, and OPP protection, the ASR-2000 series also incorporates the Fan fail alarm function and AC fail alarm function.
The specifications apply when the ASR-2000 is powered on for at least 30 minutes under +20°C~+30°C.
Input Ratings (AC rms)
Model | ASR-2050/ASR-2050R | ASR-2100/ASR-2100R | |
Norminal input voltage | 100 Vac to 240 Vac | ||
Input voltage range | 90 Vac to 264 Vac | ||
Phase | Single phase, Two-wire | ||
Input frequency range | 47 Hz to 63 Hz | ||
Max. power consumption | 800 VA or less | 1500 VA or less | |
Power factor*1 | 100Vac | 0.95 (typ.) | |
200Vac | 0.90 (typ.) | ||
Max. input current | 100Vac | 8 A | 15 A |
200Vac | 4 A | 7.5 A |
*1. For an output voltage of 100 V/200 V (100V / 200V range), maximum current, and a load power factor of 1.
AC Mode Output Ratings (AC rms)
Model | ASR-2050/ASR-2050R | ASR-2100/ASR-2100R | |
| Setting Range*1 | 0.0 V to 175.0 V / 0.0 V to 350.0 V | |
Setting Resolution | 0.1 V | ||
Accuracy*2 | ±(0.5 % of set + 0.6 V / 1.2 V) | ||
Output phase | Single phase, Two-wire | ||
Maximum current*3 | 100 V | 5 A | 10 A |
200 V | 2.5 A | 5 A | |
Maximum peak current*4 | 100 V | 20 A | 40 A |
200 V | 10 A | 20 A | |
Power capacity | 500 VA | 1000 VA | |
Frequency | Setting range | AC Mode: 40.00 Hz to 999.9 Hz, AC+DC Mode: 1.00 Hz to 999.9 Hz | |
Setting resolution | 0.01 Hz (1.00 to 99.99 Hz), 0.1 Hz (100.0 to 999.9 Hz) | ||
Accuracy | For 45 Hz to 65 Hz: 0.01% of set For 40 Hz to 999.9 Hz: 0.02% of set | ||
Stability*5 | ± 0.005% | ||
Output on phase | 0.0° to 359.9° variable (setting resolution 0.1°) | ||
DC offset*6 | Within ± 20 mV (TYP) |
*1. 100 V / 200 V range
*2. For an output voltage of 17.5 V to 175 V / 35 V to 350 V, sine wave, an output frequency of 45 Hz to 65 Hz, no load, DC voltage setting 0V (AC+DC mode) and 23°C ±5°C
*3. For an output voltage of 1 V to 100 V / 2 V to 200 V.
Limited by the power capacity when the output voltage is 100 V to 175 V / 200 V to 350 V.
*4. With respect to the capacitor-input rectifying load. Limited by the maximum current.
*5. For 45 Hz to 65 Hz, the rated output voltage, no load and the resistance load for the maximum current, and the operating temperature.
*6. In the case of the AC mode and output voltage setting to 0 V.
Output Rating for DC Mode
Model | ASR-2050/ASR-2050R | ASR-2100/ASR-2100R | |
Voltage | Setting Range*1 | -250 V to +250 V / -500 V to +500 V | |
Setting Resolution | 0.1 V | ||
Accuracy*2 | ±(|0.5 % of set| + 0.6 V / 1.2 V) | ||
Maximum current*3 | 100 V | 5 A | 10 A |
200 V | 2.5 A | 5 A | |
Maximum peak current*4 | 100 V | 20 A | 40 A |
200 V | 10 A | 20 A | |
Power capacity | 500 W | 1000 W |
*1. 100 V / 200 V range
*2. For an output voltage of -250 V to -25 V, +25 V to +250 V / -500 V to -50 V, +50 V to +500 V, no load, AC volatge setting 0V (AC+DC mode) and 23℃ ± 5℃
*3. For an output voltage of 1.4 V to 100 V / 2.8 V to 200 V.
Limited by the power capacity when the output voltage is 100 V to 250 V / 200 V to 500 V.
*4. Within 5 ms, Limited by the maximum current.
Output Voltage Stability
Model | ASR-2050/ASR-2050R | ASR-2100/ASR-2100R |
Line regulation*1 | ±0.2% or less | |
Load regulation*2 | 0.15% @45 - 65Hz 0.5% @DC, all other frequencies (0 to 100%, via output terminal) | |
Ripple noise*3 | 0.7 Vrms / 1.4 Vrms (TYP) |
*1. Power source input voltage is 100 V, 120 V, or 230 V, no load, rated output.
*2. For an output voltage of 75 V to 175 V / 150 V to 350 V, a load power factor of 1, stepwise change from an output
current of 0 A to maximum current (or its reverse), using the output terminal on the rear panel.
*3. For 5 Hz to 1 MHz components in DC mode using the output terminal on the rear panel.
Output Voltage Waveform Distortion Ratio, Output Voltage Response Time, Efficiency
Model | ASR-2050/ASR-2050R | ASR-2100/ASR-2100R |
Output voltage waveform distortion ratio*1 | 0.5 % or less | |
Output voltage response time*2 | 100 us (TYP) | |
Efficiency*3 | 70 % or more |
*1. At an output voltage of 50 V to 175 V / 100 V to 350 V, a load power factor of 1, and in AC and AC+DC mode.
*2. For an output voltage of 100 V / 200 V, a load power factor of 1, with respect to stepwise change from an output current of 0 A to the maximum
current (or its reverse). 10% ~ 90% of output voltage
*3. For AC mode, at an output voltage of 100 V / 200 V, maximum current, and load power factor of 1 and sine wave only.
Measured Value Display
All accuracy of the measurement function is indicated for 23 °C±5 °C.
Model | ASR-2050/ASR-2050R | ASR-2100/ASR-2100R | ||
Voltage
| RMS, AVG value*1 | Resolution | 0.1 V | |
Accuracy*2 | For 45 Hz to 65 Hz and DC: ±(0.5 % of reading + 0.3 V / 0.6 V) | |||
PEAK value | Resolution | 0.1 V | ||
Accuracy | For 45 Hz to 65 Hz and DC: ±(|2 % of reading| + 1 V / 2 V) | |||
Current |
RMS, AVG value | Resolution | 0.01 A | |
Accuracy*3 | For 45 Hz to 65 Hz and DC: | For 45 Hz to 65 Hz and DC: | ||
PEAK value | Resolution | 0.1 A | ||
Accuracy*4 | For 45 Hz to 65 Hz and DC: | For 45 Hz to 65 Hz and DC: | ||
| Active (W) | Resolution | 0.1 / 1 W | |
Accuracy*5 | ±(2 % of reading + 0.5 W) | ±(2 % of reading + 1 W) | ||
Apparent (VA) | Resolution | 0.1 / 1 VA | ||
Accuracy*5*6 | ±(2 % of reading + 0.5 VA) | ±(2 % of reading + 1 VA) | ||
Reactive (VAR) | Resolution | 0.1 / 1 VAR | ||
Accuracy*5*7 | ±(2 % of reading + 0.5 VAR) | ±(2 % of reading + 1 VAR) | ||
Load power factor | Range | 0.000 to 1.000 | ||
Resolution | 0.001 | |||
Load crest factor | Range | 0.00 to 50.00 | ||
Resolution | 0.01 | |||
Harmonic voltage | Range | Up to 40th order of the fundamental wave | ||
Full Scale | 175 V / 350 V, 100% | |||
Resolution | 0.1 V, 0.01% | |||
Accuracy*8 | Up to 20th ±(0.2 % of reading + 0.5 V / 1 V) 20th to 40th ±(0.3 % of reading + 0.5 V / 1 V) | |||
Harmonic current | Range | Up to 40th order of the fundamental wave | ||
Full Scale | 5 A / 2.5 A, 100% | 10 A / 5 A, 100% | ||
Resolution | 0.01 A, 0.01% | |||
Accuracy*3 | Up to 20th ±(1 % of reading + 0.1 A / 0.05 A) 20th to 40th ±(1.5 % of reading + 0.1 A / 0.05 A) | Up to 20th ±(1 % of reading + 0.2 A / 0.1 A) 20th to 40th ±(1.5 % of reading + 0.2 A / 0.1 A) |
*1. The voltage display is set to RMS in AC/AC+DC mode and AVG in DC mode.
*2. AC mode: For an output voltage of 17.5 V to 175 V / 35 V to 350 V and 23 °C ± 5 °C.
DC mode: For an output voltage of 25 V to 250 V / 50 V to 500 V and 23 °C ± 5 °C.
*3. An output current in the range of 5 % to 100 % of the maximum current, and 23 °C ± 5 °C.
*4. An output current in the range of 5 % to 100 % of the maximum peak current in AC mode, an output current in the range of 5 % to 100 % of the maximum instantaneous current in DC mode, and 23 °C ± 5 °C. The accuracy of the peak value is for a waveform of DC or sine wave
*5. For an output voltage of 50 V or greater, an output current in the range of 10 % to 100 % of the maximum current,
DC or an output frequency of 45 Hz to 65 Hz, and 23 °C ± 5 °C.
*6. The apparent and reactive powers are not displayed in the DC mode.
*7. The reactive power is for the load with the power factor 0.5 or lower.
*8. An output voltage in the range of 17.5 V to 175 V / 35 V to 350 V and 23 °C ± 5 °C.
Others
Model | ASR-2050/ASR-2050R | ASR-2100/ASR-2100R | |
Protections | OCP, OTP, OPP, FAN Fail | ||
Display | TFT-LCD, 4.3 inch | ||
Memory Function | 10 sets for Store and Recall settings | ||
Arbitrary Wave | Number of memories | 16 (nonvolatile) | |
Waveform length | 4096 words |
General Specifications
Model | ASR-2050/ASR-2050R | ASR-2100/ASR-2100R | ||
Interface |
Standard | USB | Type A: Host, Type B: Slave, Speed: 1.1/2.0, USB-CDC | |
LAN | MAC Address, DNS IP Address, User Password, Gateway IP Address, Instrument IP Address, Subnet Mask | |||
EXT Control | External Signal Input | |||
Factory | GPIB | SCPI-1993, IEEE 488.2 compliant interface | ||
RS-232C | Complies with the EIA-RS-232 specifications | |||
Insulation | Between input and chassis, | 500 Vdc, 30 MΩ or more | ||
Withstand | Between input and chassis, | 1500 Vac, 1 minute | ||
EMC | EN 61326-1 (Class A) | |||
Safety | EN 61010-1 | |||
Environment | Operating environment | Indoor use, Overvoltage Category II | ||
Operating temperature range | 0 °C to 40 °C | |||
Storage temperature range | -10 °C to 70 °C | |||
Operating humidity range | 20 %rh to 80 % RH (no condensation) | |||
Storage humidity range | 90 % RH or less (no condensation) | |||
Altitude | Up to 2000 m | |||
Dimensions (mm) | ASR-2000: 285(W)×124(H)×480(D) (not including protrusions) | |||
Weight | ASR-2000: Approx. 11.5 kg |
External Signal Input (AC+DC-EXT, AC-EXT Mode)
Specification | Factory Default | |
Gain setting range | 100 V range: 0.0 to 250.0 times | 100 |
200 V range: 0.0 to 500.0 times | 200 | |
Input terminal | BNC connector | |
1 MΩ | ||
Input voltage range | ±2.5 V (A/D resolution 12 bit) | |
±10 V | ||
Gain resolution | 0.1 times | |
±5 % (DC, or 45Hz ~ 65 Hz, gain is at initial value, with rate voltage output, no load) |
EXT: Output voltage (V) = External signal input (V) x Gain (V/V)
External Signal Input (AC+DC-ADD, AC-ADD Mode
Specification | Factory Default | |
Gain setting range | 100 V range: 0.0 to 250.0 times | 100 |
200 V range: 0.0 to 500.0 times | 200 | |
Input terminal | BNC connector | |
1 MΩ | ||
Input voltage range | ±2.5 V (A/D resolution 12 bit) | |
±10 V | ||
Input frequency range | DC to 999.9 Hz (sine wave) DC to 100 Hz (other than sine wave) | |
0.1 times | ||
Accuracy | ±5 % (DC, or 45Hz ~ 65 Hz, gain is at initial value, with rate voltage output, no load) |
ADD: Output voltage (V) = External signal input (V) x Gain (V/V) + Internal signal source setting (V)
External Synchronous Signal or Line (AC+DC-SYNC, AC-SYNC)
Specification | Factory Default | |
Synchronization signal source | External synchronization signal (EXT) or Power input (LINE) | LINE |
40.00 Hz to 999.9 Hz | ||
Input terminal | BNC connector | |
1 MΩ | ||
Threshold of input voltage | TTL level | |
500 us | ||
Nondestructive maximum input voltage | ±10 V | |
0.1 Hz | ||
Accuracy | ±0.2 Hz |
- • Electronic Products/Electronic Component Development Test
- • Automotive Electrical Equipment Simulation Test
- • Household Appliance Application Test
Products In This Series
As low as
Now $2,343.00As low as
Now $3,210.00