GW Instek ASR-2050 500VA Programmable AC/DC Power Source

SKU
ASR-2050
Manufacturer:
GW Instek
GW Instek

Key Features:

  • Output Rating: AC 0 – 350 Vrms, DC 0 - ± 500 V
  • Output Frequency up to 999.9 Hz
  • DC Output (100% of Rated Power)
  • Measurement Items: Vrms, Vavg, Vpeak, Irms, IpkH, Iavg, Ipeak, P, S, Q, PF, CF
  • Voltage and Current Harmonic Analysis(THDv, THDi)
  • Remote Sensing Capability
  • OVP, OCP, OPP, OTP, AC Fail Detection and Fan Fail Alarm
  • Support Arbitrary Waveform Function
  • Output Capacity: 500VA
  • Customized Phase Angle for Output On/Off
  • Sequence and Simulation Function(up to 10 sets)
  • Interface: USB, LAN(std.); RS-232+GPIB(opt.)
  • Built-in External Control I/O and External Signal Input
  • Built-in Output Relay Control
  • Memory Function (up to 10 sets)
  • Built-in Web Server
Product Options:
$2,446.00

Secured and trusted checkout with

GW Instek’s ASR-250 is a 500VA AC+DC power source aiming for system integration or desktop applications, providing both rated power output for AC output and rated power output for DC output. Nine ASR-2000 output modes are available, including 1) AC power output mode (AC-INT Mode), 2) DC power output mode (DC-INT Mode), 3) AC/DC power output mode (AC+DC-INT Mode), 4) External AC signal source mode (AC-EXT Mode), 5) External AC/DC signal source mode (AC+DC-EXT Mode), 6) External AC signal superposition mode (AC-ADD Mode), 7) External AC/DC signal superposition mode (AC+DC-ADD Mode), 8) External AC signal synchronization mode (AC-SYNC Mode), 9) External AC/DC signal synchronization mode (AC+DC-SYNC Mode).

Users are suited with waveform output capabilities to satisfy the test requirements of different electronic component development, automotive electrical devices and home appliance, including 1) Sequence mode generates waveform fallings, surges, sags, changes and other abnormal power line conditions; 2) Arbitrary waveform function allows users to store/upload user-defined waveforms; and 3) Simulate mode simulates power outage, voltage rise, voltage fall, and frequency variations. When the ASR-2000 series power source outputs, it can also measure Vrms, Vavg, Vpeak, Irms, Iavg, Ipeak, IpkH, P, S, Q, PF, CF, 40th-order Voltage Harmonic and Current Harmonic. More still, the Remote sense function provides precision voltage output. The Customized Phase Angle for Output On/Off function can set the starting angle and ending angle of the voltage output according to the test requirements. V-Limit, Ipeak-Limit, F-Limit, OVP, OCP, OPP function settings can protect the DUT during the measurement process. In addition to OTP, OCP, and OPP protection, the ASR-2000 series also incorporates the Fan fail alarm function and AC fail alarm function.

The specifications apply when the ASR-2000 is powered on for at least 30 minutes under +20°C~+30°C.

 

Input Ratings (AC rms)

Model

ASR-2050/ASR-2050R

ASR-2100/ASR-2100R

Norminal input voltage

100 Vac to 240 Vac

Input voltage range

90 Vac to 264 Vac

Phase

Single phase, Two-wire

Input frequency range

47 Hz to 63 Hz

Max. power consumption

800 VA or less

1500 VA or less

Power factor*1

100Vac

0.95 (typ.)

200Vac

0.90 (typ.)

Max. input current

100Vac

8 A

15 A

200Vac

4 A

7.5 A

*1. For an output voltage of 100 V/200 V (100V / 200V range), maximum current, and a load power factor of 1.

 

AC Mode Output Ratings (AC rms)

Model

ASR-2050/ASR-2050R

ASR-2100/ASR-2100R

 


Voltage

Setting Range*1

0.0 V to 175.0 V / 0.0 V to 350.0 V

Setting Resolution

0.1 V

Accuracy*2

±(0.5 % of set + 0.6 V / 1.2 V)

Output phase

Single phase, Two-wire

Maximum current*3

100 V

5 A

10 A

200 V

2.5 A

5 A

Maximum peak current*4

100 V

20 A

40 A

200 V

10 A

20 A

Power capacity

500 VA

1000 VA

 

 

Frequency

Setting range

AC Mode: 40.00 Hz to 999.9 Hz, AC+DC Mode: 1.00 Hz to 999.9 Hz

Setting resolution

0.01 Hz (1.00 to 99.99 Hz), 0.1 Hz (100.0 to 999.9 Hz)

Accuracy

For 45 Hz to 65 Hz: 0.01% of set

For 40 Hz to 999.9 Hz: 0.02% of set

Stability*5

± 0.005%

Output on phase

0.0° to 359.9° variable (setting resolution 0.1°)

DC offset*6

Within ± 20 mV (TYP)

*1. 100 V / 200 V range

*2. For an output voltage of 17.5 V to 175 V / 35 V to 350 V, sine wave, an output frequency of 45 Hz to 65 Hz, no load, DC voltage setting 0V (AC+DC mode) and 23°C ±5°C

*3. For an output voltage of 1 V to 100 V / 2 V to 200 V.

Limited by the power capacity when the output voltage is 100 V to 175 V / 200 V to 350 V.

*4. With respect to the capacitor-input rectifying load. Limited by the maximum current.

*5. For 45 Hz to 65 Hz, the rated output voltage, no load and the resistance load for the maximum current, and the operating temperature.

*6. In the case of the AC mode and output voltage setting to 0 V.

 

Output Rating for DC Mode

Model

ASR-2050/ASR-2050R

ASR-2100/ASR-2100R

 

Voltage

Setting Range*1

-250 V to +250 V / -500 V to +500 V

Setting Resolution

0.1 V

Accuracy*2

±(|0.5 % of set| + 0.6 V / 1.2 V)

Maximum current*3

100 V

5 A

10 A

200 V

2.5 A

5 A

Maximum peak current*4

100 V

20 A

40 A

200 V

10 A

20 A

Power capacity

500 W

1000 W

*1. 100 V / 200 V range

*2. For an output voltage of -250 V to -25 V, +25 V to +250 V / -500 V to -50 V, +50 V to +500 V, no load, AC volatge setting 0V (AC+DC mode) and 23℃ ± 5℃

*3. For an output voltage of 1.4 V to 100 V / 2.8 V to 200 V.

Limited by the power capacity when the output voltage is 100 V to 250 V / 200 V to 500 V.

*4. Within 5 ms, Limited by the maximum current.

 

Output Voltage Stability

Model

ASR-2050/ASR-2050R

ASR-2100/ASR-2100R

Line regulation*1

±0.2% or less

Load regulation*2

0.15% @45 - 65Hz

0.5% @DC, all other frequencies (0 to 100%, via output terminal)

Ripple noise*3

0.7 Vrms / 1.4 Vrms (TYP)

*1. Power source input voltage is 100 V, 120 V, or 230 V, no load, rated output.

*2. For an output voltage of 75 V to 175 V / 150 V to 350 V, a load power factor of 1, stepwise change from an output

current of 0 A to maximum current (or its reverse), using the output terminal on the rear panel.

*3. For 5 Hz to 1 MHz components in DC mode using the output terminal on the rear panel.

 

Output Voltage Waveform Distortion Ratio, Output Voltage Response Time, Efficiency

Model

ASR-2050/ASR-2050R

ASR-2100/ASR-2100R

Output voltage waveform distortion ratio*1

0.5 % or less

Output voltage response time*2

100 us (TYP)

Efficiency*3

70 % or more

*1. At an output voltage of 50 V to 175 V / 100 V to 350 V, a load power factor of 1, and in AC and AC+DC mode.

*2. For an output voltage of 100 V / 200 V, a load power factor of 1, with respect to stepwise change from an output current of 0 A to the maximum

current (or its reverse). 10% ~ 90% of output voltage

*3. For AC mode, at an output voltage of 100 V / 200 V, maximum current, and load power factor of 1 and sine wave only.

 

Measured Value Display

All accuracy of the measurement function is indicated for 23 °C±5 °C.

Model

ASR-2050/ASR-2050R

ASR-2100/ASR-2100R

 

 

Voltage

 

 

 

RMS, AVG value*1

Resolution

0.1 V

Accuracy*2

For 45 Hz to 65 Hz and DC: ±(0.5 % of reading + 0.3 V / 0.6 V)
For 40 Hz to 999.9 Hz: ±(0.7 % of reading + 0.9 V / 1.8 V)

PEAK value

Resolution

0.1 V

AccuracyFor 45 Hz to 65 Hz and DC: ±(|2 % of reading| + 1 V / 2 V)

 

 

 

 

Current

 

 

RMS, AVG value

Resolution0.01 A

 

 

Accuracy*3

For 45 Hz to 65 Hz and DC:
±(0.5 % of reading + 0.02 A / 0.02 A)
For 40 Hz to 999.9 Hz:
±(0.7 % of reading + 0.04 A / 0.04 A)

For 45 Hz to 65 Hz and DC:
±(0.5 % of reading + 0.04 A / 0.02 A)
For 40 Hz to 999.9 Hz:
±(0.7 % of reading + 0.08 A / 0.04 A)

 

PEAK value

Resolution0.1 A
Accuracy*4

For 45 Hz to 65 Hz and DC:
±(|2 % of reading| + 0.2 A / 0.1 A)

For 45 Hz to 65 Hz and DC:
±(|2 % of reading| + 0.2 A / 0.1 A)

 

 


Power

Active (W)Resolution0.1 / 1 W
Accuracy*5±(2 % of reading + 0.5 W)±(2 % of reading + 1 W)
Apparent (VA)Resolution0.1 / 1 VA
Accuracy*5*6±(2 % of reading + 0.5 VA)±(2 % of reading + 1 VA)
Reactive (VAR)Resolution0.1 / 1 VAR
Accuracy*5*7±(2 % of reading + 0.5 VAR)±(2 % of reading + 1 VAR)
Load power factorRange0.000 to 1.000
Resolution0.001
Load crest factorRange0.00 to 50.00
Resolution0.01

 

Harmonic voltage
Effective value (rms)
Percent (%)
(AC-INT and 50/60 Hz only)

RangeUp to 40th order of the fundamental wave
Full Scale175 V / 350 V, 100%
Resolution0.1 V, 0.01%

 

 

Accuracy*8

Up to 20th
±(0.2 % of reading + 0.5 V / 1 V)
20th to 40th
±(0.3 % of reading + 0.5 V / 1 V)

 

 

Harmonic current
Effective value (rms)
Percent (%)
(AC-INT and 50/60 Hz only)

RangeUp to 40th order of the fundamental wave
Full Scale5 A / 2.5 A, 100%10 A / 5 A, 100%
Resolution0.01 A, 0.01%

 

 

Accuracy*3

Up to 20th
±(1 % of reading + 0.1 A / 0.05 A)
20th to 40th
±(1.5 % of reading + 0.1 A / 0.05 A)
Up to 20th
±(1 % of reading + 0.2 A / 0.1 A)
20th to 40th
±(1.5 % of reading + 0.2 A / 0.1 A)

*1. The voltage display is set to RMS in AC/AC+DC mode and AVG in DC mode.
*2. AC mode: For an output voltage of 17.5 V to 175 V / 35 V to 350 V and 23 °C ± 5 °C.
DC mode: For an output voltage of 25 V to 250 V / 50 V to 500 V and 23 °C ± 5 °C.
*3. An output current in the range of 5 % to 100 % of the maximum current, and 23 °C ± 5 °C.
*4. An output current in the range of 5 % to 100 % of the maximum peak current in AC mode, an output current in the range of 5 % to 100 % of the maximum instantaneous current in DC mode, and 23 °C ± 5 °C. The accuracy of the peak value is for a waveform of DC or sine wave
*5. For an output voltage of 50 V or greater, an output current in the range of 10 % to 100 % of the maximum current,
DC or an output frequency of 45 Hz to 65 Hz, and 23 °C ± 5 °C.
*6. The apparent and reactive powers are not displayed in the DC mode.
*7. The reactive power is for the load with the power factor 0.5 or lower.
*8. An output voltage in the range of 17.5 V to 175 V / 35 V to 350 V and 23 °C ± 5 °C.


Others

Model

ASR-2050/ASR-2050R

ASR-2100/ASR-2100R

Protections

OCP, OTP, OPP, FAN Fail

Display

TFT-LCD, 4.3 inch

Memory Function

10 sets for Store and Recall settings

Arbitrary Wave

Number of memories

16 (nonvolatile)

Waveform length

4096 words

 

General Specifications

Model

ASR-2050/ASR-2050R

ASR-2100/ASR-2100R

 

 

 

Interface

 

 

Standard

USB

Type A: Host, Type B: Slave, Speed: 1.1/2.0, USB-CDC

LAN

MAC Address, DNS IP Address, User Password, Gateway IP Address, Instrument IP Address, Subnet Mask

EXT Control

External Signal Input
External Control I/O

Factory
Optional

GPIB

SCPI-1993, IEEE 488.2 compliant interface

RS-232C

Complies with the EIA-RS-232 specifications

Insulation
resistance

Between input and chassis,
output and chassis, input and output

500 Vdc, 30 MΩ or more

Withstand
voltage

Between input and chassis,
output and chassis, input and output

1500 Vac, 1 minute

 

 

EMC

EN 61326-1 (Class A)
EN 61326-2-1/-2-2 (Class A)
EN 61000-3-2 (Class A, Group 1)
EN 61000-3-3 (Class A, Group 1)
EN 61000-4-2/-4-3/-4-4/-4-5/-4-6/-4-8/-4-11    (Class A, Group 1)
EN 55011 (Class A, Group1)

Safety

EN 61010-1

 

 

 

Environment

Operating environment

Indoor use, Overvoltage Category II

Operating temperature range

0 °C to 40 °C

Storage temperature range

-10 °C to 70 °C

Operating humidity range

20 %rh to 80 % RH (no condensation)

Storage humidity range

90 % RH or less (no condensation)

Altitude

Up to 2000 m

Dimensions (mm)

ASR-2000: 285(W)×124(H)×480(D) (not including protrusions)
ASR-2000R: 213(W)×124(H)×480(D) (not including protrusions)

Weight

ASR-2000: Approx. 11.5 kg
ASR-2000R: Approx. 10.5 kg

 

External Signal Input (AC+DC-EXT, AC-EXT Mode)

 

Specification

Factory Default

Gain setting range

100 V range: 0.0 to 250.0 times

100

200 V range: 0.0 to 500.0 times

200

Input terminal

BNC connector

1 MΩ

Input voltage range

±2.5 V (A/D resolution 12 bit)

±10 V

 

Gain resolution

0.1 times

±5 %

(DC, or 45Hz ~ 65 Hz, gain is at initial value, with rate voltage output, no load)

EXT: Output voltage (V) = External signal input (V) x Gain (V/V)

 

External Signal Input (AC+DC-ADD, AC-ADD Mode

 SpecificationFactory Default
Gain setting range100 V range: 0.0 to 250.0 times100
200 V range: 0.0 to 500.0 times200
Input terminalBNC connector
1 MΩ
Input voltage range±2.5 V (A/D resolution 12 bit)
±10 V
Input frequency rangeDC to 999.9 Hz (sine wave)
DC to 100 Hz (other than sine wave)
0.1 times
Accuracy±5 %
(DC, or 45Hz ~ 65 Hz, gain is at initial value, with rate voltage output, no load)

ADD: Output voltage (V) = External signal input (V) x Gain (V/V) + Internal signal source setting (V)

 

External Synchronous Signal or Line (AC+DC-SYNC, AC-SYNC)

 SpecificationFactory Default

 

Synchronization signal source

External synchronization signal (EXT)
or
Power input (LINE)

LINE
40.00 Hz to 999.9 Hz
Input terminalBNC connector
1 MΩ
Threshold of input voltageTTL level
500 us
Nondestructive maximum input voltage±10 V
0.1 Hz
Accuracy±0.2 Hz
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
  • • Electronic Products/Electronic Component Development Test
  • • Automotive Electrical Equipment Simulation Test
  • • Household Appliance Application Test

Products In This Series

As low as