The MetraPort 40S is a universal digital multimeter that is ideal for use in general electrical engineering, electronics and automotive service. In addition to basic multimeter functions, the MetraPort 40S has temperature, capacitance, frequency and RPM measurement capabilities. The MetraPort 40S has a unique hinged display with an adjustable reading angle, and a neck strap for hands free operation. When the meter display is folded closed, the meter is switched off automatically, and the display and control panel are protected against damage.
Includes
- • MetraPort 40S
- • 2x batteries
- • KS17-2 safety cable set
- • Carrying strap
- • Quick guide operating instructions
- • CD-ROM including operation instructions
Display
LCD panel (95 x 40 mm) with analog and digital display including
unit of measure, type of current and various special functions
Type COG (chip on glass) for good legibility from
various directions
Background illumination
Background illumination (by means of LEDs) is activated with two
keys, and is switched off automatically after approximately 1
minute.
Analog
Display LCD scale with pointer
Scale length 80 mm for V and A ,
67 mm for all other ranges
Scaling 5 ... 0 ... ± 30 with 35 scale divisions
for ...,
0 ... 30 with 30 scale divisions in all other
ranges
Polarity display With automatic switching
Overflow display With triangle
Measuring rate 20 measurements per second
Digital
Display / char. height 7-segment characters / 20 mm
Number of places 4¾ places 31000 steps
Overflow display “OL” appears
Polarity display “–” (minus sign) is displayed
if plus pole is connected to “⊥”
Measuring rate 2 measurements per second
Refresh rate
V (DC) , V~ (AC), A, Ω,
°C (Pt100, Pt1000) 2 per second
Hz 1 per second
°C (K) 0.5 per second
Power Supply
Battery 2 ea. 1.5 V mignon cell,
alkaline manganese per IEC LR6,
zinc-carbon per IEC R6
Service life With alkaline manganese: approx. 200 h
With zinc-carbon: approx. 80 h
Battery test Battery capacity display with battery
symbol in 4 segments
Power saving circuit The device is switched off automatically:
– If the measured value remains
unchanged for a period of approximately
10 minutes, and if none of the controls
are activated during this time.
Automatic shutdown can be deactivated.
– If battery voltage drops to below
approx. 1.8 V
Fuses
Range
300 μA to 10 A – Resetable auto-fuse
15 A, 240 V AC, 50 V DC
– A slow-blow fuse is additionally
connected in series to the auto-fuse, the
blowing or absence of which is detected
automatically (display “FUSE”):
T16A/500V AC, 6.3 mm x 32 mm
1.5 kA switching capacity at 500 V AC
and ohmic load
Electrical Safety
Safety class II per IEC 61010-1:2001/EN 61010-
1:2001/VDE 0411-1:2002
Measuring category CAT II
Operating voltage 300 V
Fouling factor 2
Test voltage 2.3 kV~ per IEC 61010-1:2001/
EN 61010-1:2001/VDE 0411-1:2002
Electromagnetic Compatibility (EMC)
Interference emission EN 61326-1:2006 class B
Interference immunity EN 61326-1:2006
EN 61326-2-1:2006
Ambient Conditions
Accuracy range 0 °C ... +40 °C
Operating temp. range -10 °C ... +50 °C
Storage temp. range -25 °C ... +70 °C (without batteries)
Relative humidity Max. 75%, no condensation allowed
Elevation To 2000 m
Deployment Indoors, except within specified ambient
conditions
USB Interface
The USB port is electrically isolated from the measuring circuit.
Operating voltage 5 V DC ±10% from USB Port of PC
Current consumption 50 mA max, 25 mA typ.
USB-Interface Type Mini-B, 5-pin, USB 1.1
Transfer 38400 Baud
parameters (1 Stopbit, no parity)
Pinning 1: VCC, 2: D–, 3: D+,
4: ID/not assigned, 5: GND