We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
The GMC Instruments MetraHIT 30M multimeter is a high performance, precision measuring instrument for R&D labs, industrial applications, universities, government agencies, test stands, manufacturing, Quality Assurance and instrument service & calibration companies. With a display range of 1,200,000, as well as exceptional accuracy and long-term stability, it fulfills all of the demands of calibration and R&D labs. Battery operation allows for mobile use of the instrument for demanding maintenance work and field calibration tasks. An optional ac adapter can be utilized for stationary, long-term operation on the bench. The 30M is the only 6.5 digit hand held multimeter available. No portable multimeter can meets its accuracy specifications!
TRMS Measurement for Distorted Waveshapes
The utilized measuring method allows for TRMS measurements for up to 100 kHz at crest factors of up to 10, independent of the waveshape.
Sampling Rate
The sampling rate determines the interval at which the respective measurement value is saved to memory. Depending upon measured quantity and resolution, the interval can be set within a range of 0.01 s to 60 s.
Automatic and Manual Measuring Range Selection
The desired measured quantity is selected with the rotary switch. The measuring range is automatically adapted to the measured quantity. The measuring range can also be selected manually.
Averaging Filter
A digital filter (1/2/4/8/16 measurement values) is used to smooth noisy measurement signals.
Storing MIN-MAX Values to Memory
In addition to displaying the current measurement value, the minimum or maximum value can be continuously updated and stored to memory at the selected sampling rate.
Overload Protection
The instrument is protected against overloading in all measuring functions. All current measuring ranges are equipped with a selfresetting, electronic fuse.
Battery Saver Circuit
The instrument is shut down automatically if the measurement value remains unchanged for approximately 10 minutes, and if none of the operating elements have been activated during this time. Automatic shut-down can be disabled.
Protective Cover for Rugged Use
A soft rubber boot with tilting stand protects the instrument from damage due to impacts or drops. The rubber material provides the instrument with a secure stance, even if it has been set up on a vibrating surface.
Memory Mode
The instrument is equipped with a 128 kB measurement value memory with backup battery. The memory can be laid out in 1 to 15 blocks. New values can be written to memory, even after completion of a given measurement without loss of data, until the maximum capacity of 30,000 measurement value has been used up. The data can be stored to intermediate memory, or uploaded directly to a PC. The system records measurement values in relative time. Use as a real-time data logger is not possible. Depending upon the measured quantity, the interval can be set in steps of 10 ms, 100 ms, 1 s, 10 s and 60 s. Individual measurement values can also be saved to memory by pressing a key. The contents of the memory can be read out with the help of METRAwin 10/METRAHit analysis software and a PC which has been connected to the multimeter via the METRAHit BD232 IR adapter. The measuring instrument includes a serial, duplex data interface for remote control and transmission of data via infrared light.
Reference Conditions
Ambient Temperature +23 °C ±2 K
Relative Humidity 40 ... 60%
Measured Quantity
Frequency 45 ... 65 Hz
Measured Quantity
Waveshape sine
Battery Voltage 3 V ±0.1 V
Power Pack Voltage 5 V ±0.2 V
Display
LCD field (65 mm x 30 mm) with digital display, including display
of unit of measure, current type and various special functions.
Display/Char. Height 7 Segment / 12 mm
Number of Places 6½
Overload Display “OL” is displayed as of 1,250,000
Polarity Display “–” sign is displayed when plus pole is
connected to “–V”
Display Refresh Rate
V, mA, Ω, °C/°F once per second
Hz 1 to 0.5 time per second
Power Supply
Battery 2 ea. 1.5 V mignon cells
alkaline-manganese per IEC LR6
Battery Test Automatic display of the “-||− ” symbol
when battery voltage falls to below
approx. 2.3 V
Battery Saver Circuit
The instrument is shut down automatically if the measurement
value remains unchanged for approximately 10 minutes, and if
none of the operating elements have been activated during this
time. Automatic shut-down can be disabled.
Fuses
All current measuring ranges are protected by an internal 250 mA
fuse. A defective fuse may only be replaced by GMC-I Service
GmbH. Voltage at the measuring current circuit may not exceed
600 Veff.
Electrical Safety
Protection Class II per IEC/EN 61010-1:2001 /VDE 0411-1:2002
Measuring Category II
Operating Voltage 600 V
Contamination Level 2
Test Voltage 3,7 kV~ per IEC/EN 61010-1:2001 /VDE 0411-1:2002
Electromagnetic Compatibility (EMC)
Interference emission EN 61326:2006 class B
Interference immunity EN 61326-1: 2006
EN 61326-2-1: 2006
Ambient Conditions
Operating Temp. - 5 °C ... +50 °C
Storage Temperature -25 °C ... +70 °C (without batteries)
Relative Humidity max. 75%, no condensation allowed
Elevation to 2000 m
Deployment indoors; outdoors only within the specified ambient conditions
Warm-Up Time 5 min.
Mechanical Design
Protection instrument: IP 50, terminals: IP 20
Dimensions 84 mm x 195 mm x 35 mm
Weight approx. 350 gr. with batteries