We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
General | |||
Input Channels | One | ||
Input Types | Digital (S3L) | Serial ASCII, TTL level, 9600 bps | |
| Frequency | Range | 0.5 to 1500 Hz |
| Accuracy | 0.5% of reading | |
Measurement Types | Flow, pH/ORP, Conductivity/Resistivity, Salinity, Pressure, Temperature, Level, Dissolved Oxygen, Batch or user-defined (via 8058) | ||
Enclosure and Display | |||
Case Material | PBT | ||
Window | Shatter-resistant glass | ||
Keypad | 4 buttons, injection-molded silicone rubber seal | ||
Display | Backlit, 7 and 14-segment | ||
Update Rate | 1 s | ||
LCD Contrast | 5 settings | ||
Indicators | “Dial-type” digital bar graph. LEDs for Open Collector, Relays and Warning Indicator | ||
Enclosure Size | ¼ DIN | ||
Mounting | 9900-1P |
| |
| Panel | ¼ DIN, ribbed on four sides for panel mounting clip inside panel, silicon gasket included. Optional rear enclosure with flat cover available for waterproof protection when installed inside a panel. | |
Wall | Options include 9900-1P installed in pre-wired NEMA enclosure or inside of rear enclosure with hinged cover. | ||
Pipe | Optional Rear Enclosure with hinged cover and 9900-1P for pipe mount installation | ||
Mounting | 9900-1 |
| |
Field (Integral) | Options include yellow universal or integral kits for installation with sensor | ||
Display Ranges | |||
pH | 0.00 to 15.00 pH | ||
pH Temperature | -39.99 °C to 149.99 °C | -40 °F to 302 °F | |
ORP | -1999 to +1999 mV | ||
Flow Rate | -9999 to 99999 units per second, minute, hour or day | ||
Totalizer | 0.00 to 99999999 units | ||
Conductivity | 0.0000 to 99999 μS, mS, PPM and PPB (TDS), kΩ, MΩ | ||
Conductivity Temperature | -100 °C to 250 °C | –148 °F to 350 °F (application and sensor dependent) | |
Temperature | -99 °C to 350 °C | –99 °F to 350 °F | |
Pressure | -40 to 1000 psi | ||
Level | -9999 to 99999 m, cm, ft, in, % | ||
Volume | 0 to 99999 cm3, m3, in3, ft3, gal, L, lb, kg, % | ||
Salinity | 0 to 99.97 PPT | ||
Dissolved Oxygen | PPM 0-50, % SAT 0-200, 0 to 999.9 TORR | ||
Dissolved Oxygen | -99 °C to 350 °C | –99 °F to 350 °F | |
Environmental | |||
Ambient Operating Temperature |
Backlit LCD | -10 °C to 70 °C | 14 °F to 158 °F |
Storage Temperature | -15 °C to 70 °C | 5 °F to 158 °F |
Relative Humidity | 0 to 100% condensing for field mount; 0 to 95% non-condensing for panel mount | |
Maximum Altitude | 4,000 m (13,123 ft) | |
Enclosure Rating | NEMA 4X/IP65 (front face only on panel mount); field mount is 100% NEMA 4X/IP65 | |
Electrical Requirements | ||
Power to Sensors |
Voltage | +4.9 to 5.5 VDC @ 25 °C, regulated |
Current | 1.5 mA max in loop power mode (up to 2.0 mA with 24 V @ 300 Ω max. loop impedance); |
Short Circuit | Protected |
Isolation | Low voltage (< 48V AC/DC) to loop with DC power connected |
No isolation when using loop power only |
Terminal Blocks | Pluggable screw type | 14 AWG max wire gauge |
Input Power | ||
DC | 10.8 to 35.2 VDC, regulated | |
9900 without Relay Module | 200 mA @ 10.8 VDC to 35.2 VDC | |
9900 with Relay Module | 300 mA @ 10.8 VDC to 35.2 VDC | |
Overvoltage Protection | 48 Volt Transient Protection Device | |
Current limiting for circuit protection | ||
Reverse-Voltage Protection | ||
Loop Power | ||
No DC Power Input |
| Max. Loop Impedance | 50 Ω @ 12 V | 325 Ω @ 18 V | 600 Ω @ 24 V |
With DC Power Input or with 2nd loop, all the time |
| Max. Loop Impedance | 250 Ω @ 12 V | 500 Ω @ 18 V | 750 Ω @ 24 V |
Relay Specifications | ||||
| Dry-Contact Relays (2) | Open Collector (1) | ||
Type | SPDT | N/A | ||
Form | C | N/A | ||
Max. Current Rating | 5 A resistive | 50 mA DC | ||
Max. Voltage Rating | 30 VDC or 250 VAC | 30 VDC | ||
Hysteresis | Adjustable (absolute in engineering units) (EUs) | |||
Latch | Reset in test screen only | |||
Delay | 9999.9 seconds (max.) | |||
Test Mode | Set On or Off | |||
Cycle Time | 99999 seconds (max.) | |||
Maximum Pulse Rate | 300 pulses/minute | |||
Proportional Pulse | 400 pulses/minute | |||
Volumetric Pulse Width | 0.1 to 3200 s | |||
Pulse Width Modulation | 0.1 to 320 s | |||
Input Types | ||||
Digital (S3L) or AC frequency | ||||
4 to 20 mA input via the 8058-1 | ||||
pH/ORP input via the Digital (S3L) output from the 2750/2751 pH/ORP Sensor Electronics | ||||
Raw Conductivity/Resistivity input directly from Signet Conductivity/Resistivity electrodes via Direct Conductivity/Resistivity Module or via 2850 | ||||
Input Specifications | ||||
Digital (S3L) | Serial ACSII, TTL level, 9600 bps | |||
Frequency Input |
| Sensitivity | 80 mV @ 5 Hz, gradually increasing with frequency |
Span | 0.5 Hz to 1500 Hz @ TTL level input | |
Accuracy | ± 0.5% or reading max error @ 25 °C | |
Resolution | 1 μS | |
Repeatability | ± 0.2% of reading |
Power Supply | ||
| Rejection | ±1 μA per volt |
Short Circuit | Protected | |
Update Rate | (1/frequency) + 150 ms | |
Output Specifications | ||
Current Output - One (1); Two (2) with 4 to 20 mA Output Module |
| Current Loop Output Standard | ANSI-ISA 50.00.01 Class H | ||
Current Output | 4 to 20 mA, isolated, fully adjustable and reversible | |||
Span | 3.8 to 21 mA | |||
Zero | 4.0 mA factory set; user programmable from 3.8 to 5.0 mA | |||
Full Scale | 20.00 mA factory set; user programmable from 19.0 to 21.0 mA | |||
Accuracy | ±32 μA max. error @ 25 °C @ 24 VDC | |||
Resolution | 6 μA or better | |||
Temperature Drift | ±1 μA per °C | |||
Power Supply Rejection | ±1 μA per V | |||
Isolation | Low voltage (< 48 VAC/DC) | |||
Voltage | 12 to 32 VDC ±10% | |||
Max. Impedance | 250 Ω @ 12 VDC | 500 Ω @ 18 VDC | 750 Ω @ 24 VDC | |
Max. Impedance | 50 Ω @ 12 VDC | 325 Ω @ 18 VDC | 600 Ω @ 24 VDC | |
Update Rate | 150 mS nominal | |||
Short circuit and reverse polarity protected | ||||
Adjustable Span | Reversible | |||
Error Condition | Selectable error condition 3.6 or 22 mA | |||
Actual update rate determined by sensor type | ||||
Test Mode | Increment to desired current (range 3.8 to 21.00 mA) | |||
Shipping Weights | ||||
Base Unit | 0.63 kg | 1.38 lb | ||
H COMM Module | 0.16 kg | 0.35 lb | ||
Conductivity Module | 0.16 kg | 0.35 lb | ||
Relay Module | 0.19 kg | 0.41 lb | ||
Batch Module | 0.16 kg | 0.35 lb | ||
4 to 20 Output Module | 0.16 kg | 0.35 lb | ||
Rear Enclosure, Hinged cover | 0.30 kg | 0.65 lb | ||
Rear Enclosure, Flat cover | 0.28 kg | 0.60 lb | ||
Standards and Approvals | ||||
| CE, UL, CUL, FCC | |||
RoHS Compliant, China RoHS | ||||
Lloyd’s Register | ||||
Manufactured under ISO 9001 and ISO 14001 for Environmental Management and OHSAS 18001 for Occupational Health and Safety |