Fluke’s Ti95 Fluke Connect FCC Kit includes the Fluke Ti95 industrial infrared camera and an a3001 FC iFlex module, providing one comprehensive kit for fast and productive inspections. The Ti95 FCC Kit allows users to execute rapid scans, take true RMS measurements around awkward sized conductors and share and collaborate data wirelessly and safely through the Fluke Connect App.
Fluke Connect® with ShareLive™ video call is the most comprehensive software and wireless test tool family that keeps you in contact with your entire team without leaving the field. The Fluke Connect family offers the largest system of connected test tools in the world. The software is compatible with the HTC One and One M8 running Android 4.4.x or higher, LG G3 and Nexus 5 running Android 4.4.x or higher, Samsung Galaxy S4 running Android 4.3.x or higher, Samsung Galaxy S5 running Android 4.4.x or higher. It also works with the iPhone models 4S and higher running iOS 8.0 or higher, iPad Air and iPad Mini (2nd generation) in an iPhone frame on iPad and iPod Touch (5th generation) and comes with over 30 different Fluke products. Please see our Fluke Connect category for the complete collection of Fluke Connect Products. Take me to Fluke Connect (Click Here).
- • Share images in real-time across teams with Fluke Connect
- • Save time by creating and emailing reports from the jobsite
- • Capture multiple measurements all in one report
- • WiFi upload and free storage with Fluke Cloud™
- • Store thousands of images with internal 4 GB memory and external slot
Fluke Ti95 Infrared Camera
Key Features | |
IFOV (spatial resolution) | 5.6 mRad |
Resolution | 80 x 80 (6,400 pixels) |
Field of view | 26° H x 26° V |
Wireless connectivity | Yes |
Fluke Connect™ app compatible | Yes, with included wireless SD card (where available) |
IR-Fusion® technology | PIP (46 cm (18 in) and beyond) |
Focus system | Fixed focus 46 cm (18 in) and beyond |
Ruggedized display | 3.5 inch diagonal (portrait format) |
Rugged, ergonomic design for one-handed use | Yes |
Thermal sensitivity (NETD) | ≤ 0.10°C at 30°C target temp (100 mK) |
Temperature measurement range (not calibrated below -10°C) | -20°C to +250°C (-4°F to +482°F) |
Level and span | Smooth auto and manual scaling |
Fast auto toggle between manual and auto modes | Yes |
Fast auto-rescale in manual mode | Yes |
Minimum span (in manual mode) | 2.5°C |
Minimum span (in auto mode) | 5°C |
Built-in digital camera (visible light) | 2 megapixel industrial performance |
Frame rate | 9 Hz only |
Data Storage and Image Capture | |
Extensive SD memory system | Removable 8 GB SD memory card and 8 GB wireless SD card (where available) |
Direct download via USB-to-PC connection | |
Image capture, review, save mechanism | One-handed image capture, review, and save capability |
File formats image | Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2) |
No analysis software required for non-radiometric (.bmp, .jpg) files | |
Memory review | Thumbnail view navigation and review selection |
Software | SmartView® software, Fluke Connect™, and SmartView® Mobile app - full analysis and reporting software |
Export file formats with SmartView® software | BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF |
Battery | |
Batteries (field-replaceable, rechargeable) | One lithium ion smart battery pack with five-segment LED display to show charge level |
Battery life | Four+ hours continuous use per battery pack (assumes 50% brightness of LCD and average usage) |
Battery charge time | 2.5 hours to full charge |
AC battery charging system | In-imager charging. AC mains adapters included in 9 Hz versions. Optional two-bay AC battery charger (110 VAC to 220 VAC, 50/60 Hz) or optional 12 V automotive charging adapter. |
AC operation | AC operation with included power supply (110 VAC to 220 VAC, 50/60 Hz). AC mains adapters included. |
Power saving | User selectable sleep and power off modes |
Temperature Measurement | |
Accuracy | ±2°C or 2% (at 25°C nominal, whichever is greater) |
On-screen emissivity correction | Yes (both number and table) |
On-screen reflected background temperature compensation | Yes |
Color Palettes | |
Standard palettes | 6: Ironbow, blue-red, high-contrast, amber, hot metal, grayscale |
General Specifications | |
Infrared spectral band | 9 μm to 15 μm (long wave) |
Operating temperature | -10°C to +50°C (14°F to 122°F) |
Storage temperature | -20°C to +50°C (-4°F to 122°F) |
Relative humidity | 10% to 95%, non-condensing |
Center-point temperature measurement | Yes |
Spot markers | Hot and cold spot markers |
Center box (MIN-MAX-AVG) | Fixed-size measurement box with MIN-MAX-AVG temp |
Safety standards | CSA (US and CAN): C22.2 No. 61010-1-04, UL: UL STD 61010-1 (2nd Edition), ISA: 82.02.01 |
Electromagnetic compatibility | EN 61326-1:2006 IEC 61326-1:2005 |
C Tick | IEC/EN 61326-1 |
US FCC | EN61326-1; FCC Part 5 |
Vibration | 2G, IEC 68-2-6 |
Shock | 25G, IEC 68-2-29 |
Drop | Engineered to withstand 2 meter (6.5 feet) drop |
Size (H x W x L) | 28.4 x 8.6 x 13.5 cm (11.2 x 3.4 x 5.3 in) |
Weight (battery included) | 0.726 kg (1.6 lb) |
Enclosure rating | IP54 (protected against dust, limited ingress; protection against water spray from all directions) |
Warranty | Two-years (standard), extended warranties are available |
Recommended calibration cycle | Two-years (assumes normal operation and normal aging) |
Supported languages | Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish |
Fluke a3001 FC Wireless iFlex® AC Current Module
Specifications | ||
Range | 0.5 A to 2500 A AC | |
Resolution | 0.1 A | |
Accuracy | 3% ±5 digits (5 Hz to 500 Hz) | |
Crest factor (50 Hz / 60 Hz) | 3.0 at 1100 A 2.5 at 1400 A 1.42 at 2500 A add 2% for C.F. > 2 | |
LCD w/ backlight | 3½ digits | |
Log rate/interval | 1 sec minimum/adjustable by PC or front panel | |
Battery type | 2 AA, NEDA 15 A, IEC LR6 | |
Battery life | 400 hours | |
Memory | Record up to 65,000 readings | |
RF communications | 2.4 GHZ ISM Band | |
RF communication range | Open air, unobstructed | Up to 20 m |
Obstructed, sheetrock wall | Up to 6.5 m | |
Obstructed, concrete wall or steel electrical enclosure | Up to 3.5 m | |
Operating temperature | -10°C to +50°C | |
Storage temperature | -40°C to +60°C | |
Temperature coefficient | Add 0.1 x (specified accuracy) / °C (< 18°C or > 28°C) | |
Operating humidity | 90% at 35°C 75% at 40°C 45% at 50°C | |
Altitude | Operating | 2,000 m |
Storage | 12,000 m | |
EMC | EN 61326-1:2006 | |
Safety compliance | IEC 61010-1, 600 V CAT IV/1000 V CAT III, 3rd edition | |
Safety rating | CAT IV 600 V, CAT III 1000 V | |
Certifications | CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE | |
Ingress Protection (IP) rating | IP42 | |
Pollution Degree | 2 | |
Jaw opening | 25.4 cm (10 in) coil | |
Size (H x W x D) | 16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in) | |
Weight | .22 kg (8 oz) | |
Warranty | Three years | |
Not compatible with Fluke CNX test tools |