We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
The i30 current clamp is based on Hall Effect technology for use in measurement of both DC and AC current. The i30 may be used in conjunction with multimeters, recorders and other suitable recording instruments for accurate non-intrusive current measurement.
Electrical Specifications | |
Specified current range | 30 mA to 30 A DC, 30 mA to 20 A AC rms |
Usable current range | 5 mA to 30 A DC, 30 mA to 20 A AC rms |
Crest Factor | 1.4 in |
Output sensitivity | 100 mV/A |
Accuracy (at +25°C) | ±1% of reading ±2 mA |
Resolution | ±1 mA |
Load impedance | > 10 k Ohms and ≤ 100pF |
Conductor position sensitivity | ±1% relative to center reading |
Frequency range | DC to 20 kHz (-0.5 dB) |
Temperature coefficient | ±0.01% of reading/°C |
Power supply | 9 V Alkaline, MN1604/PP3, 30 hours, low battery indicator |
Working voltage (see Safety Standards section) | 300 V AC rms or DC |
General Specifications | |
Maximum conductor size | 19 mm diameter |
Output connection | 4 mm safety connector |
Output zero | Manual adjust via thumbwheel |
Cable length | 1.5 meters |
Operating temperature range | 0°C to +50°C |
Storage temperature range (with battery removed) | -20°C to +85°C |
Operating humidity | 15% to 85% (non-condensing) |
Weight | 250 g |
Safety standards | BS EN 61010-1:2001 |
BS EN 61010-2-032:2002 | |
BS EN 61010-031:2002 | |
300 V rms, Category III, Pollution Degree 2 | |
Use of the probe on uninsulated conductors is limited to 300 V AC rms or DC and frequencies below 1 kHz | |
EMC Standards | EN 61326: 1998 +A1, A2, and A3 |
Manuals
Write Your Own Review